Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Carrier, modelo 38APS025-065

Fabricar: Carrier
Tamaño del archivo: 2.33 mb
Nombre del archivo: 38ap-5si.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


• Follow all safety codes. • Wear safety glasses and work gloves. • Use care in handling and installing this accessory. WARNING To avoid the possibility of electrical shock, open and tag alldisconnects before installing this equipment. Failure to doso could result in severe personal injury. INTRODUCTION An accessory long line check valve must be installed for: 1. Any 025-030 size dual circuit unit where the evaporator is located higher than the condensing unit and thelinear line length exceeds 55 ft (16.8 m). 2. Any size dual or single circuit unit with linear linelength of 100 ft (30.5 m) or more. ACCESSORY USAGE CAUTION For all units with liquid lines of 100 ft (30.5 m) or more orany 025-030 size dual circuit unit application where evapo- rator is located higher than the condensing unit and liquidlines exceed 55 feet (16.8 m), a long line check valve mustbe installed to prevent compressor failure. The long linecheck valve accessory must be mounted in the liquid lineas close as possible to the condensing unit. The long line check valve accessory must be mounted in theliquid line near the condensing unit. The valve is brazed intothe liquid line. Fitting adapters may be required to connect thecheck valve to the liquid line. The valve may be mounted inany orientation, horizontally or vertically. See Fig. 1 for dimen- sions. Figure 2 shows the location of the check valves on arooftop installation. Figure 3 shows the location of the checkvalves on a ground level installation. UNIT SIZE CIRCUIT TYPE CHECK VALVE SIZE (in. ODF) ACCESSORY USAGE (QUANTITY) — PART NO. 38AP-900--011 012 013 38APD/S025 Dual 5/8 + 5/8 2 — — Single 5/8 1 — — 38APD/S027 Dual 5/8 + 5/8 2 — — Single 5/8 1 — — 38APD/S030 Dual 5/8 + 5/8 2 — — Single 7/8 — 1 — 38APD/S040 Dual 5/8 + 5/8 2 — — Single 7/8 — 1 — 38APD/S050 Dual 5/8 + 5/8 2 — — Single 7/8 — 1 — 38APD060 Dual 5/8 + 7/8 1 1 — 38APS065 Single 7/8 — 1 — 38APD070 Dual 7/8 + 7/8 — 2 — 38APD080 Dual 7/8 + 7/8 — 2 — 38APD090 Dual 7/8 + 7/8 — 2 — 38APD100 Dual 7/8 + 7/8 — 2 — 38APD115 Dual 7/8 + 7/8 — 2 — 38APD130 Dual 7/8 + 1 1/8 — 1 1 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53380009-01 Printed in U.S.A. Form 38AP-5SI Pg 1 5-10 Replaces: New ENSURE FLOW ARROWS BYPASS CHECK VALVE (508) (94) DIRECTION OF FLOW LIQUID LINE CHECK VALVE NOTE: Dimensions are in inches. Dimensions in () are in millimeters. Fig. 1 — Long Line Check Valve Accessory Dimensions (Part No. 38AP-900---011 Shown) 2 40RU 3 FT MAX FOR SHORT RISER a38-7098_gs a38-7098_gs LEGEND LLSV — Liquid Line Solenoid Valve NEC — National Electrical Code TXV — Thermostatic Expansion Valve Piping Double Riser Piping (if required) *Field supplied. †If double suction riser is required for piping system, size short riser (3 ft [0.9 m] maximum) according to base unit installation instructions. **Field supplied. See base unti installation instructions for refrigerant specialties part numbers. NOTES: 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System Design Manual for details. 2. All wiring must comply with the applicable local and national codes. 3. Wiring and piping shown are general points-of-connection guides only and are not...

Otros modelos de este manual:
Los acondicionadores de aire - 38APD025-130 (2.33 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría