Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Ducane, modelo B

Fabricar: Ducane
Tamaño del archivo: 760.13 kb
Nombre del archivo: d2ac14blbclc-100.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This feature is standard on all Allied Air Enterprises furnace and air handler products. 2AC14 Split System Air Conditioner 1 Cooling Performance with Air Handlers & Furnaces 36, 42, 48, 60 4 Outdoor Model Indoor 1 i/lodel Variable Speed Furnace SEER EER Rated ARI Capacity1 Rated Sensible Capacity CFM Refrigerant Connection Refrigerant Line Size Indoor Metering Device Piston or Field Installed TXV Factory Installed TXV Outdoor Indoor n io ct u S id ui Req'd Indoor2 Orifice Optional Field Installed Orifice n io u S id n io u S id Q_ <..0 m * * < CNI RBCS2M36C****P+TXV RBCS2M36C****T - 14.00 12.50 34,800 25,400 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 RBCS2M36V****P+TXV -- -- 15.00 13.50 35,000 25,600 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 E(C,H,M,U)1P36NB+TXV E(C,H,M,U)2T36NB CMPEV100 15.00 13.00 34,600 25,200 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 E(C,H,M,U)1P36NB+TXV E(C,H,M,U)2T36NB MPGAV100 15.00 13.00 34,600 25,200 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 E(C,H,M,U)1P43NB+TXV E(C,H,M,U)2T43NB CMPEV100 15.00 13.50 34,800 25,400 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 E(C,H,M,U)1P43NB+TXV E(C,H,M,U)2T43NB MPGAV100 15.00 13.50 34,800 25,400 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 E(C,M,U)1P36NA+TXV E(C,M,U)2T36NA CMPEV050,075 15.00 13.00 34,600 25,300 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 E(C,M,U)1P36NA+TXV E(C,M,U)2T36NA MPGAV050,075 15.00 13.00 34,600 25,300 1250 3/4 3/8 3/4 3/8 3/4 3/8 -- A2TXV01 2AC14*42P RBCS2M42C****P+TXV RBCS2M42C*****T - 14.00 12.00 40,000 29,200 1450 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 RBCS2M42V****P+TXV -- -- 15.00 13.00 40,500 29,565 1450 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P49NC+TXV E(C,H,U)2T49NC CMPEV0125 15.00 13.00 40,000 29,200 1450 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P49NC+TXV E(C,H,U)2T49NC MPGAV0125 15.00 13.00 40,000 29,200 1450 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P62NC+TXV E(C,H,U)2T62NC CMPEV125 15.00 13.00 40,000 29,200 1450 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P62NC+TXV E(C,H,U)2T62NC MPGAV125 15.00 13.00 40,000 29,200 1450 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 2AC14*48P RBCS2M48C****P+TXV RBCS2M48C*****T - 14.50 12.50 48,000 34,600 1650 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 RBCS2M48V****P+TXV -- -- 15.00 13.00 48,000 34,600 1650 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P49NC+TXV E(C,H,U)2T49NC CMPEV125 14.50 12.50 48,000 34,600 1650 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P49NC+TXV E(C,H,U)2T49NC MPGAV125 14.50 12.50 48,000 34,600 1650 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P62NC+TXV E(C,H,U)2T62NC CMPEV125 14.50 12.50 54,000 34,600 1650 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 E(C,H,U)1P62NC+TXV E(C,H,U)2T62NC MPGAV125 14.50 12.50 54,000 34,600 1650 7/8 3/8 7/8 3/8 7/8 3/8 -- A2TXV02 2AC14*60P RBCS2M60V****P+TXV -- - 14.00 12.00 54,000 41,600 1950 7/8 3/8 7/8 3/8 1-1/8 3/8 -- A2TXV02 E(C,H,U)1P62NC+TXV E(C,H,U)2T62NC MPGAV125 13.50 11.50 54,000 41,600 1950 7/8 3/8 7/8 3/8 1-1/8 3/8 -- A2TXV02 ** ...

Otros modelos de este manual:
Los acondicionadores de aire - BC (760.13 kb)
Los acondicionadores de aire - 2AC14 (760.13 kb)
Los acondicionadores de aire - L (760.13 kb)
Los acondicionadores de aire - LC (760.13 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría