Manual de usuario Haier, modelo AB362ACEAA
Fabricar: Haier Tamaño del archivo: 877.88 kb Nombre del archivo:
Idioma del manual:
|
|
|
|
Enlace gratuito para este manual disponible en la parte inferior de la página
Resumen del manual
Connect wires of the same specifications at two sides. Don't connect wires of the same specifications at one side. Don't connect wires of the different specifications. <> Bar Fig. 1 9 INSTALLATION OF ORNAMENT PANEL Cautions for the installation Be sure to show customers Operation Manual and guide them how to operate unit correctly. Before installation. read also the Installation Manual of indoor unit. With this ornament , 2 or 3 air flow direction is not available. Suitable height is 3 m. Accessory Pad Pad 1. Prepare ornament panel Handling of ornament panel Ornament panel shall not be placed face down or against wall, neither on an uneven object. 45 Fig. 2 Adbesive tape Don' t bend carelessly the swing flap, or, problem may occur. (1) Remove air inlet grill from ornament panel * Push in the bar on inlet grill and lift it up. (Refer to Fig. 1) 2 1 Lift it up for about 45 degree and remove it from ornament. Tear off adhesive tape fixing air filter on the back of the air inlet grill. (Refer to Fig. 2) (2) Remove cover plate at corner Slide Tear off the adhesive tape, and slide it off. (Refer to Fig. 3) Fig. 3 26 27 (1) 3. Install ornament panel on indoor unit. As shown in Fig.7,match the position of swing flap motor with that of the indoor unit piping hole , so that ormament panel can be placed on to indoor unit. Installation of ornament panel Place the holding ring on swing flao motor side teporarily on hooks of the indoor unit. (2 pcs) Put the other two holding rings on the hooks at both side of the indoor unit. (Care should be taken not to push wiring of swing flap motor into seals). Screw in all 4 screws under holding ring for about 15mm. (Pancl will rise). Adjust the ornament panel as per Fig. 7 to cover opening on the ceiling. Tighten screws to redrce the thickness of seals between ornament and indoor unit to 5-8mm. If indoor unit is at horizontal level and water drainage is smooth, then, indoor unit height can be adjusted throrgh holes at corners of ornament panel. If screws are not tighten tight, problems in Fig, 8 might occur. Tighten screws properly. If there are still space after tightening of screws, please readjust the height of indoor unit. (Refer to Fig. 9) Leave no space. Fig. 9 Gas leakage. Gas leakage from roof. Contamination Mist exists and drop down. Fig. 8 For indoor unit installation, please refer to Installation Manual. (2) 1 2 3 4 5 5 _ 8mm 3 2 2 1 4 Holding ring Piping hole position Swing flap motor Fig. 7 Indoor unit Seal Ceiling material Ornament panel Hook Caution 2. Mounting on high ceiling (1) Ornament panel can be mounted on ceiling as high as 3 m. (2) Please install pad as accessary. Cut open the pad along cutting ling. Use part a only and discard part b . (Refer to Fig. 4) Install part a of the pad on the place shown in Fig. 5. Refer to Fig. 6. (3)Wiring on ornament panel Connecting of wiring of the swing flap motor on ornament panel. (2 places) (Refer to Fit . 10) If connecting is not made, error code (A7) appears on remote controller. So, make proper connecting. Side of ornament panel Fig. 10 Wiring diagram Side of indoor unit Fig. 4 50 Cutting line a 100 b Place it on the frame. Part a of the pad Leave no space. Fig. 6 Part a of the pad Swing flap motor Fig. 5 1 2 Installation Procedure Installation Procedure Item to the checked Pay special care to the following and check after installation Unproper installation may cause Check Is indoor unit firmly installed? Is gas leakage check performed? Is unit properly insulated? Is water drainage smooth? Is power voltage meet that stipulated on the nameplate? Is wiring and piping correctly arranged? Is unit safely grounded? Is wire size correct? Are there any obstacles on air inlet and outlet grill of indoor and outdoor unit? Is record made for piping length and refrigerant charging amount? Unit might fall down, make vibration or noise. This may lead to gas shortage. Dew or water drop may occur. Dew or water drop may occur. Problem may occur or parts got burned. Problem may occur or parts got burned. There might be a danger of electric shock. Problem may occur or parts got burned. This may cause poor cooling. It is hard to control refrigerant charging amount. 4. Installation of inlet grill and cover plate Installation of inlet grill Install in reversed order of "Prepare ornament pandl". Inlet grill can be adjusted into four directions by turning inlet grill. Inlet grill position can be adjusted as per customers request. (1) Install cover plate on the corner As shown in Fig. 11 tie the cover plate onto the bolt on ornament plate. Install cover plate onto ornament plate. (Refer to Fig. 12) (2) When installing inlet grill, take care not to twist wiring of swing flap motor. 2 1 ATTENTION: after finishing installation,confirm no refrigerant leakage. Slide all five hold rings to let them drop in holes on ornament plate, Fig. 12Fig. 11 28 HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangan...
Otros modelos de este manual:
Los acondicionadores de aire - AB182ACEAA (877.88 kb)
Los acondicionadores de aire - AB182ACERA (877.88 kb)
Los acondicionadores de aire - AB242ACEAA (877.88 kb)
Los acondicionadores de aire - AB242ACERA (877.88 kb)