|
Resumen del manual
E. Example: set unit A to address 1. Continuously press the emergency switch for about 15 seconds, the buzzer will sound 4 times(PI PI PI PI) and then leave go of the switch. At this time, the indoor unit has entered the address setting procedure. But F. Use the controller to turn on the indoor unit. At this time, the controller should be changed from OFF to ON, and then theTIMER LED flshes once. That is to say, the address setting is enabled. G. Press the button"SLEEP " on the controller, the times you press it stands for the address you want to set, detailed as following: Press button " SLEEP " once, the address is "1 ", and the TIMER LED flashes once; Press button " SLEEP " twice, the address is " 2 ", and theTIMER LED flashes twice; Press button " SLEEP " three times, the address is " 3 ", and the TIMER LED flashes three times; Press button " SLEEP " four times, the address is " 4 ", and the TIMER LED flashes four times; H. Use the remote controller to turn off the unit, At this time, the controller should be changed from ON to OFF, and the unit will exit the address setting procedure, the address will be memorized. The LED board will always display the address of this indoor unit until the system be powered off. I. If you want to change the address, please repeat the above steps from E to G. J. After setting all the addresses, please power off the system and then power on again. Otherwise the system will not start to work. K. Once the addresses are successfully set, please do not change it any more to avoid confusion. 3. Address setting procedure when using the DIP switches SW01 and SW03. A. The DIP switches SW01 and SW03 are on the indoor unit PCB. B. Before carrying out the address setting work, the system must be powered off. C. Take off the front panal and the filters, then take off the flaps and also the front cover,disconnect the swing motor connectors from the PCB and then take out the lower part of the PCB. D. Change the position of DIP 7 of SW01 from OFF to ON, if fail to do this, the addresses set by SW03 will not work. E. Use SW03 to set the addresses as following (DO NOT CHANGE OTHER DIP SWITCHES): 18 Instructions to installation SW01 SW03 INDOOR UNIT ADDRESS 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 ON OFF 1 2 3 4 5 6 7 8 2 ON OFF 1 2 3 4 5 6 7 8 3 1 2 3 4 5 6 7 8 ON OFF 4 4. How to check the addresses? When finish all the above works, please power off and power on again to the whole system but set all the indoor units in STANDBY. Then continously press the emergency switch until you hear the buzzer sound 5 times(Pi Pi Pi Pi Pi), and then the TIMER LED board will show the address of this indoor unit. Press any key on the remote controller, it will exit the address checking precedure. 10.Setting method of temperature compensation (For heating function only) works.Swith on the unit in heating mode by the remote controller,press the time button to set the set temp. compensatoin. so the set temp. compensation=the current set temp.-24 C.For example,if the set temp. is 24 C,the temp.compensation is 0 C;if the set temp.is 25 C,the temp. compensation is 1 C;if the set temp.is 30 C,the temp. compensation is 6 C;if the set temp.is 23 C,the temp. compensation is -1 C;if the set temp.is 16 C,the temp. compensation is -8 C;If setting is finished, press ON/OFF button, then the unit quits the temp. compensation. In 24 C heating mode,press sleep 7 times continuously.Indoor buzzer sounds 2 times,that show temp.compensatoin Set method of temperature compensation(-8 C~6 C) in heating mode with the remote controller. 19 Trouble Shooting The followings are not malfuncition Hua Hua Water flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds i Bi- Bi-i or iGodo-Godoi. It is the flowing sound of the refrigerant , not a malfunction. Cracking sound is heard This is caused by heat expansion or contraction of plastics It smells. Air blown out from the indoor unit sometimes smells. The smell results from smells of furniture, paint , tobacco absorbed by indoor unit. During operation, white fog comes out of indoor unit. When in COOL or DRY mode, a thin water fog can be seen blown out of unit ,this is the condensed fog because the suddenly cooled indoor air is blown out. Automatically switch into FAN mode during cooling. To prevent frost from being accumulated on the indoor unit heat exchanger, it sometimes automatically switched into the FAN mode,but it will soon back to the cooling mode. The air conditioner cannot be restarted soon after it stops. Air conditioner does not start? This is because of the self-protection function of the system, therefore,it cannot be restarted for about three minutes after it stops. Please wait for three minutes 20 Trouble Shooting Air does not blow or the fan speed cannot be changed during drying. In DRY mode, when room temperature becomes 2 C higher than temperature ...
Otros modelos de este manual:Los acondicionadores de aire - AB092XCERA (895.9 kb)
Los acondicionadores de aire - AB142XCERA (895.9 kb)
Los acondicionadores de aire - AB182XCERA (895.9 kb)