Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Alen, modelo C475A

Fabricar: Alen
Tamaño del archivo: 473.45 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


2 Press “TIMER” button to select OFF . 3 MODE SLEEP ON/OFF TEMPERATURE FAN SPEED AU H FAN SWEEP TIM E TIMER HOUR MINUT E RESET SET TEMP Set the clock time as Clock Setting, Press “TIME” button to select OFF, clock display will flash. 1 Press “HOUR” or “MINUTE” button; set the time to turn on the air conditioner on timer. At this time if user press “MINUTE” button, it will increase or decrease by 10 minutes. 2 Press “TIMER” button to select OFF . 3 Note: ” will be deleted. If the set time is as same to the current time, the air conditioner will be turned off at this time of next day. 1. When off timer function is set, air conditioner will be turned on immediately. It will be turned off at the set time; symbol “ OFF 2. Press “ON/OFF” to cancel “Off Timer” function, air conditioner will be turned off immediately. Program Control MODE SLEEP ON/OFF TEMPERATURE FAN SPEED AU H FAN SWEEP TIM E TIMER HOUR MINUT E RESET SET TEMP PROGRAM 1. Refer to Clock Setting to Set the clock time. 2. Refer to On Timer to Set the time to turn on the air conditioner. 3. Refer to Off Timer to Set the time to turn off the air conditioner. 1 Press “TIMER” button to select PROGRAM 2 Note: 1. In accordance with the clock time , air conditioner will select to work in “On Timer” or “Off Timer” mode automatically. PROGRAM PROGRAM ON OFF 2. Air conditioner will be turned on/off at the set time everyday. If user turns off the air conditioner by hand before the set time, then “Off timer” function will be cancelled; but “On timer” function is still effective. If user turns on the air conditioner by hand before the set time, then “On timer” function will be cancelled; but “Off timer” function is still effective. KEY-OPERATING INSTRUCTON FOR THE AIR CONDITIONER 11 Before Starting This Unit 1) Select a suitable location ,make sure you have easy access to an electrical outlet. 2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.7 Fig.7a NOTE: Step 2) is required only while using the cooling mode. Fig.7 Fig.7a 3) Plug the unit into the grounded electrical outlet. 4) Make sure the water pump drain hose is correctly installed, as Fig.8 . 5) Press the on/off button to turn on the unit. Fig.8 1. BEFORE USE Made sure the duct is installed well. Dehumidifying and Cooling Operations -The operating range for dehumidifying is 60-89,and the operating range for cooling operating is 60 -89. -If the cooling or dehumidifying operations have been switched off and need switching on again in a short time, allow approximately three minutes for the cooling or dehumidifying operations to resume. -Make sure the water pump drain hose is correctly connected to the unit. 12 Power supply: -Insert the plug of the air conditioner into a standard three prong outlet. 2. COOLING OPERATION -Connect the power and press the “ ON/OFF ” button. -Press the “ MODE” button several times until the cooling indicator light comes on. -Press the “ TEMP SETTING” buttons^or Ў to select your desired room temperature. (60-89) -Press the .FAN SPEED. button to choose the fan speed: AutoHighMediumLow. 3. DEHUMIDIFYING OPERATION -Connect the power and press the “ ON/OFF ” button. -Press the “MODE” button several times until the dehumidifying indicator light comes on. - Press the “TEMP SETTING” buttons^or Ў to select your desired room temperature. (60-89) -The fan will often run at a fixed low speed at this setting. -Keep windows and doors closed for the best dehumidifying effect. 4. HEATING OPERATION (not available for cooling-only type air conditioner) -Connect the power and press the “ ON/OFF ” button. -Press the “MODE” button several times until the heating indicator light comes on. -Press the “TEMP SETTING” button^orЎto select your desired room temperature. (60-89) -Press the “FAN SPEED” button to choose the fan speed: AutoHighMediumLow. -The fan will delay to be off for a few minutes when the AUH has been off. 5. FAN OPERATION -Connect the power and press the “ ON/OFF ” button. -Press the “MODE” button several times until the fan indicator light comes on. -Press the “FAN SPEED” button to choose the fan speed: HighMediumLow. 6. TIMER OPERATION Setting the on timer: -Press the “TIMER ON” button or “TIMER” button when the air conditioner is off . Press the “TEMP SETTING” button^orЎto select the time you need turn on the unit . -The starting time is adjustable from 01 to 24. -The operation paned window will display “ ON ”or the timer-on indicate light. Setting the off timer: -Press the “TIMER OFF” button when the air conditioner is on. Press the “TEMP SETTING” button^orЎ to select the time you need turn off the unit. -The turning off time is adjustable from 01 to 24. -The operation paned window will display “ OFF ”or the timer-off indicate light. 7. WATER PUMP DRAINAGE -Connect the water pump drain hose to the unit before operating. When the water level of the internal water tank reaches a predetermined level, the water pump will be activated and dra...

Otros modelos de este manual:
Los acondicionadores de aire - C360 (473.45 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría