Iniciar sesión:
Votos - 3, Puntuación media: 4.7 ( )

Manual de usuario Kenmore, modelo 253.79184

Fabricar: Kenmore
Tamaño del archivo: 1.55 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Then after 5 seconds the display will revert to the hours remaining. This mode can be cancelled by pressing the TIMER button. The mode will operate one time, then the above steps have to be repeated. U NOTE: Timer button is functional when On/Off button is set to either On or Off. When set to On, the amount selected is the time remaining until the unit shuts Off. When set to Off, the amount is the time until the unit turns On. Check Filter Feature: // After 250 hours of operation, the Filter Reset LED will light. This is a reminder to clean the filter housed behind the front panel to keep the unit operating efficiently. Pressing the FILTER RESET button for 3 seconds will reset this reminder and turn off the LED. Heating Feature: This feature can be used with any combination of FAN Speeds, Timer, or Sleep Modes. When in the "Heat" Mode, the fan will run continuously while heat is needed. The temperature will automatically be maintained anywhere between 55 °F(13 °C) and 80 °F (27 °C). When the set temperature is satisfied, the fan will cycle off and on to circulate and sample the room air. Note: When unit is shut off in the Heat Mode, the Fan will continue to run for a few seconds to dissipate residual heat within the unit. 7 ADDiTiONAL THINGS YOU SHOULD KNOW Now that you understand the basic operation functions, here are more control features with which you should become familiar. * The "cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time. * There is a 2-Second delay for the compressor shutting down when selecting FAN ONLY/HEAT. This is to cover the possibility of having to roll through to select another mode. * The control will maintain the set temperature within 2 degrees Fahrenheit, between 60°F and 90°F (in cool mode), 55°F and 80°F (in heat mode). * The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other and back, press and hold both the "TEMP/TIMER" Up(/_) and Down (v) buttons for 3 seconds. FAULT CODES : If the display reads "HS", "ES" or "AS", a sensor has failed. Contact 1-800-4-MY-HOME_D for repair. Heat sensor Evaporator coil sensor Air temperature sensor AUTO RE=START : After a power outage, the unit will remember the last setting and return the unit to the same setting once power is restored. FRESH AIR VENT CONTROL ( On 253.79184 model ) 1. Pushed In (Fig. 1) -Recirculates inside air 2. Partially Pulled Out (Fig. 2) -Draws fresh air into room 3. Fully Pulled Out (Fig. 3) - Exhausts air from room and draws fresh air into room Figure 1 (VENT CLOSED ) Figure 2 ( VENT OPEN ) Figure 3 ( VENT & EXHAUST OPEN ) 8 LOUVERS / AUGER WHEEL Care and Cleaning []]]_: IJJJJJlJJJJJJJJJilJJlJJ]JJJlJJ]l} 1z z Energy Saving Ideas Air Directional Louvers Air directional louvers control air flow direction. Your air conditioner has the 4-way directional system described below. The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed. Rotate the Auger Wheel until the desired Left or Right direction is obtained. Pivot horizontal louvers with your fingertips until the desired Up/Down direction is obtained. There are a total of 4 possible air directional orientations available with this system. Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and block air from flowing to cooling coils and cause an accumulation of frost on the cooling coils. • On models with Fresh Air Vent Control, push in control to vent closed position. • Open the front panel. • Grasp the filter by the center and pull up and out. • Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. • Or instead of washing, you may vacuum the filter clean. Cabinet Cleaning • Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. • Never use harsh cleaners, wax or polish on the cabinet front. / • Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. . Plug in air conditioner. Winter Storage If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with cloth or return it to the original carton. NOTE: Store air con...

Otros modelos de este manual:
Los acondicionadores de aire - 253.71124 (1.55 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría