Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Kenmore, modelo 78189

Fabricar: Kenmore
Tamaño del archivo: 1.07 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


To cancel delay stop program, press DELAY START pad after timer starts counting down, or turn unit off (press OFF pad). Adjusting Airflow Direction See Figure 38. Position of air discharge vent louvers determines directionof airflow from vent. Direction can be adjusted upward, downward, left, and right. Figure 38. Airflowfrom Air Discharge Vent 1. Airflow directioncontrol lever 2. Air discharge vent hodzontal louvers 2 Toadjustairflowupwardordownward, movehorizontal louversonoutsideofairdischargevent upordown. To adjust airflowleftor right,move airflow directioncontrol lever left or right. Energy Saving Tips In additionto operatingairconditioner in energy-saving mode, savings of energy and money can be realized by: • Increasing insulation in walls and ceilings. • Closing all heating and ventilation diffusers or vents (including furnace cold air retum vent) in area being cooled. • Closing drapes or blinds on windows that receive direct sunlight. Installwindow coverings or awnings on windows not currently covered. • Adequately ventilating attic. Heat build-up in attic adds to air conditioner cooling load. • Avoiding use of heat-producing appliances during hottest parts of day. • Turning off lightsand appliances when not needed. • For maximum efficiency and cooling, vent doorshould be closed whenever air conditioner is cooling. Operating Instructions Normal Operating Sounds Certain sounds may be made when air conditioner runs, especialJy in a cooling mode. Sounds may include: • Water splashing onto condenser; caused by slinger ring attached to condenser fan. Slinger ring picks up water (condensate) in base pan and sprays it on condenser to increase efficiency of unit. • Compressorcycles frequently. High efficiency compressors used in new Kenmora Room AirConditionersrun more frequently but for shorter periods and consume less energy than older, less efficientcompressors. • Airflowfrom air discharge vent. If sound is distracting, try adjusting louvers on discharge vent, moving objects that may be obstructing airflow, or reducing fan speed. Care and Maintenance Maintenance Schedule (below) shows maintenance I WARNING ] requiredto keep unitoperating at peak efficiency. Most maintenance can be performed using common tools, To avoid death or personal injury due to electrical equipment, and products.See Maintenance Procedures shock, turn off fan control and unplug power cord (beginningon page 24). before cleaning orperforming maintenance on this device. Large maintenance tasks, such as washing condenser and evaporator coils,shouldperformed byanauthorized Sears servicer (at owner's expense). Call 1-800-4-88 Maintenance Schedule 1222 for location of a local authorized Sears Service Kenmore Room Air Conditioners are designed and Center. manufactured to provide years of dependable service when propedy cared for and maintained. Table 2. Maintenance Schedule Maintenance Required Procedure Frequency Inspect/clean air filler. Remove air filler and inspect. Clean if required; replace. Weekly NOTE: Never operate air conditioner withfiller removed. Inspect/clean air discharge Inspect air discharge louvers, returnair grille,and electronic Weekly louvers, retum air grille, and control for dust and dirt accumulation. Clean, if necessary. electronic control. NOTE: Inspect more often in dustyenvironments. Inspect louvers on outer case Inspect louversonouter case and remove anyobstructions. Monthly for obstructions. Inspect condenser coil. Inspect condenser coil for dirt, bent fins, and other Annually obstructions. Clean/repair, if necessary. ! NOTE: Inspect mare often in dusty environments. Inspect evaporator coil. Inspect evaporator coil for dirt, bent fins, and other Annually obstructions. Clean/repair, if necessary. NOTE: nspect more often in dusty environments. I Inspect outer case for I Inspect interior and exterior of outer case for scratches, Annually signs of damage, paint blisters, rust, and other damage. Repair as necessary. NOTE: Inspect more often in salty or other corrosive environments. Inspect/clean base pan. Inspect base pan for scratches, blisters, rust, dents, and other Annually damage. Repair as necessary. Clean condensate drain passages of any accumulated material. NOTE: In areas of excessive humidity, use algicide (algae inhibitor) in base pan to help reduce algae build-up. Care and Maintenance Maintenance Procedures I WARNING I Toavoid death or personal injurydue to electrical shock, turn off fan control and unplug power cord before cleaning or performing maintenance on this device. Air Filter Removal and Cleaning NOTE: Never operate air conditioner withfilter removed. Air filter can be removed in two ways: • See Figure 39. Grasp filter handle and pullto the left. When filter clears return air grille, pull out and away from air conditioner. Figure 39. Removing Air Filter, Method One 1. Air filter See Figure 40. Slide return air grille left until insert guides are free of guide rails, then pull insert out and aw...

Otros modelos de este manual:
Los acondicionadores de aire - 70089 (1.07 mb)
Los acondicionadores de aire - 70129 (1.07 mb)
Los acondicionadores de aire - 78079 (1.07 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría