|
Resumen del manual
This is the current programmed Fan Speed. To change the programmed Fan Speed, simply press the other Fan Speed button. . Exiting the Program SET Function After changing any of the above settings, continue pressing the Program SET button until the Program SET button LED turns off. The unit will then return to the previous mode. . Activating/Deactivating a Preset Program Press the Program RUN button to activate/deactivate a preset program. The Program RUN LED will illuminate when activated. 11 OPERATION (cont.) How to Set a Program (Cont.) NOTE: • The unit will return to the previous mode if a program is turned off while it is running. • The Program RUN LED flashes while a program is running. It is illuminated continuously when the program mode is activated. • While a program is running, the program can only be stopped by pressing the Program RUN button. All other buttons are inoperable when a program is running. • The unit returns to the previous mode at the end of a program. • The unit does not have to be running to set a program. • During programming, the unit returns to the previous mode if no activity occurs within approximately 35 seconds. 12 OPERATION (cont.) Operating Modes Both Office Pro models operate in two modes, Fan Only and COOL. When in Fan Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated. • COOL Mode Both models will operate in Fan Only mode for approximately 90 seconds before the compressor engages. (Time delay setting is 90 ± 15 seconds.) • Temperature Control The room temperature thermistor allows the unit to switch automatically between COOL and Fan Only modes. This is dependent upon inlet air temperature versus SET POINT temperature. • Fan Mode Control DIP Switch The Fan Mode Control DIP Switch determines whether the FAN will continue to operate or stop when the compressor cycles off. (SET POINT temperature equals inlet air or room temperature.) The unit has been preset at the factory for continuous fan operation. • Temperature Scale Display DIP Switch The Temperature Scale Display DIP Switch changes the temperature(s) that are displayed to either °C or °F. The unit has been preset from the factory to display the temperature(s) in °F. NOTE: If you wish to change the fan mode operation (COOLOPERATE to COOLSTOP), and/or the Temperature Scale Display (°F to °C), contact your MovinCool reseller. 13 OPERATION (cont.) Emptying the Drain Tank During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will flash and the unit will shut off automatically. NOTE: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off. If a program is running, you must first press the Program RUN button. . Open the drain tank lid. . Pull the drain tank from the unit. . Remove the cap and empty the drain tank. CAP . Replace the cap and return the drain tank to the unit. . Close the drain tank lid. . If the Program RUN LED is flashing, press the COOL ON/OFF button to continue running the program. If the Program RUN LED is illuminated continuously, no further steps are necessary. If no program exists or the program was deactivated, press the COOL ON/OFF button to restart the unit. 14 OPERATION (cont.) Drain Pump Kit (Optional) (Office Pro 12 model ONLY) A drain pump kit (CPK-3) is available to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water. A B NOTE: The compressor will not operate while the drain pump is discharging water. • When the water level drops below level (B), the drain pump stops, and the compressor will restart. NOTE: If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow Drain Switch will stop the compressor operation. NOTE: If the Fan Mode Control DIP Switch (see pg. 13) is set to the STOP position, the entire unit (including fan operation) will turn off whether due to the overflow Drain Switch or while the drain pump is discharging water. DISCHARGE HOSE DRAIN PUMP DRAIN PUMP RESERVOIR 15 OPERATION (cont.) DRAIN PUMP KIT (Optional) (Office Pro 24 model ONLY) A drain pump kit (CPK-5) is available to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water. • When the water level drops below level (B), the drain pump will stop. NOTE: If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow Drain Switch will stop the compressor operation. NOTE: If the Fan Mode Control DIP Switch (see pg. 13) is set to the STOP position, the entire unit (including fan operation) will turn off due to the overflow Drain Switch. DISCHARGE HOSE DRAIN PUMP DRAIN PUMP RESERVOIR 16 DAILY I...
Otros modelos de este manual:Los acondicionadores de aire - OFFICE PRO 12 (1.14 mb)