Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Mitsubishi Electronics, modelo Mr.Slim PEH-EAK

Fabricar: Mitsubishi Electronics
Tamaño del archivo: 659.14 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Outdoor Unit and Twin-Multi Combinations Applicable indoor units 2.5HP 3HP PEH-2.5EAK PKH-3FAK PCH-3GAK PLH-3AAK PEH-3EAK Outdoor unit Twin-multi 50:50 PUH-5YKSA 2.5 + 2.5 PUH-6YKSA 3 + 3 Multi-distribution pipe SDD-50S-E Note . The capacity of both indoor units must be identical. . Different types of indoor units with identical capacities can be connected. . The height difference between both indoor units must be 1meter or less. . When two units are connected, the main unit can be used to control the operation of all units. Mr. SLIM Convenient Remote Controller Stylish wireless remote controller with all the latest programming features Wireless remote controller for PLH-AAK . FAN SPEED SELECT button Used to change fan speed. . VANE CONTROL button Used to change airflow direction. . MODE SELECTION button Used to select operating modes — Cool, Dry, and Heat, and Auto. . TIMER CONTROL buttons STOP (OFF timer): When this function is activated, the air conditioner will auto- matically stop at the preset time. START (ON timer): When this function is activated, the air conditioner will auto- matically start at the preset time. . Fan speed indicator Displays the fan speed setting (HIGH or LOW). . HOUR and MINUTE buttons Used to set the time and timer settings. . TIMER button/ RESET button Advanced MA remote controller Wired remote controller* . DOT LIQUID CRYSTAL display . MULTI-LANGUAGE display . OPERATION CONTROL function . WEEKLY TIMER *Please refer to page 4. 6 PO WER CEI LI NG CA S S E T TE PO WER CEI LI NG CA S S E T TE PLH-3AAK PLH-4AAK PLH-5AAK PLH-6AAK INDEX Specifications .........................................p.11 Option ......................................................p.13 PLH-AAKSERIES7 Design uniformity improves installation flexibility From the smallest 3HP unit to the largest 6HP model, the new high- power ceiling cassettes offer a uniformly square 950 x 950mm width and depth design. Thanks to the uniformity of the panel size, planning for unit positioning in any room is enhanced and the installation of different capacity models within the same floor space is made possible. Unit height of only 258mm [PLH-3] The new high-power ceiling cassette models boast slim body height for smooth and aesthetic installation even in limited ceiling plenum applications. PLH-3AAK 258mm PLH-4/5/6AAK 298mm (40mm less than conventional models) Automatic vane shutter When the air conditioner is not operating, the vane shutter* closes automatically to conceal the air outlet and create an aesthetically appealing flat surface. * This feature will not activate when the vane is set at fixed position. Wide-flow air outlet The new high-power ceiling cassettes offer a wide-flow air outlet that enables effective air conditioning of atrium-type ceilings up to 4.2 meters in height. The demands of high- ceiling applications such as halls, showrooms or shopping malls can now Ideal for high- ceiling applications as high as 4.2m(PLH-4/5/6) Vane shutter closes automatically During operation When turned off ¦ 4-way high ceiling 2 4.2m ¦ 3-way standard 3.6m be fully answered thanks to this powerful yet highly efficient airflow. Specifications according to ceiling height and number of vents ¦ 4-way standard 3.2m PLH-3 PLH-4/5/6 Standard High ceiilng 1 High ceil...

Otros modelos de este manual:
Los acondicionadores de aire - Mr.Slim PCH-3GAK (659.14 kb)
Los acondicionadores de aire - Mr.Slim PCH-GAK (659.14 kb)
Los acondicionadores de aire - Mr.Slim PKH-3FAK (659.14 kb)
Los acondicionadores de aire - Mr.Slim PKH-FAK (659.14 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría