Manual de usuario Bard, modelo WL484

Fabricar: Bard
Tamaño del archivo: 274.93 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


A pressure table can be found later in the manual covering all models. It is imperative to match the correct pressure table to the unit by model number. Manual 2100-400 Page 15 TROUBLESHOOTING FAN BLADE SETTING DIMENSIONS Shown in Figure 10 is the correct fan blade setting dimension for proper air delivery across the outdoor coil. Any service work requiring removal or adjustment in the fan and/or motor area will require that the dimensions below be checked and blade adjusted in or out on the motor shaft accordingly. FIGURE 9 FAN BLADE SETTING TABLE 5 FAN BLADE SETTING DIMENSION Dimension Model A WL423 WL484 1.75 WL602 3. Remove screws holding fan shroud to condenser and bottom. Nine (9) screws. 4. Unwire condenser fan motor. 5. Slide complete motor, fan blade, and shroud assembly out the left side of the unit. 6. Service motor/fan as needed. 7. Reverse steps to reinstall. REFRIGERANT CHARGE The correct system R-22 charge is shown on the unit rating plate. Optimum unit performance will occur with a refrigerant charge resulting in a suction line temperature (6” from compressor) as shown in Table 6. TABLE 6 REFRIGERANT CHARGE Model Rated Airflow 95 OD Temperature 82 OD Temperature WL423 1400 54-52 66-64 WL484 1550 56-54 67-65 WL602 1700 55-53 62-60 REMOVAL OF FAN SHROUD The suction line temperatures in table above are based upon 80° F dry bulb / 67° F wet bulb (50% R.H.) 1. Disconnect all power to the unit. temperature and rated airflow across the evaporator 2. Remove the screws holding both grilles, one on each during cooling cycle. side of unit, and remove grilles. TABLE 7 INDOOR BLOWER PERFORMANCE CFM @ 230V E.S.P. In H20 WL423, WL484 WL602 Low 230V High 230V Low 230V High 230V Dry Coil Wet Coil Dry Coil Wet Coil Dry Coil Wet Coil Dry Coil Wet Coil .0 .1 .2 .3 .4 .5 1650 1550 1450 1350 1300 ---1600 1500 1400 1300 1175 ---1885 1770 1635 1500 1370 1250 1800 1665 1540 1400 1285 1150 1600 1525 ------------1450 1375 ------------2200 2100 2000 1875 1775 1650 2000 1900 1800 1700 1600 1475 Manual 2100-400 Page 16 TABLE 8 TABLE 9 RECOMMENDED AIRFLOW MAXIMUM ESP OF OPERATION Model Rated CFM * Rated ESP * Recommended Airflow Range WL423 1400 .30 1600 -1150 WL484 1550 .20 1750 -1285 WL602 1700 .30 1950 -1375 ELECTRIC HEAT ONLY * Rated CFM and ESP on high speed tap. Model WL423 WL484 WL602 KW High Speed Low Speed High Speed Low Speed High Speed Low Speed -A05 .50 .50 .50 .50 .50 .50 -A10 .50 .50 .50 .50 .50 .50 -A15 .50 .50 .50 .50 .50 .50 -B00 .50 .50 .50 .50 .50 .50 -B09 .50 .50 .50 .50 .50 .50 -B15 .50 .50 .50 .50 .50 .50 -C09 .50 .50 .50 .50 .50 .50 -C15 .50 .50 .50 .50 .50 .50 Values shown are for units equipped with standard 1 inch throwaway filter or 1 inch washable filter. Derate ESP by .15 for 2 inch pleated filters. TABLE 10 PRESSURE TABLE COOLING Air Temperature Entering Outdoor Coil °F Model Return Air Temperature Pressure 75 80 85 90 95 100 105 110 115 WL423 DB75 deg. WB62 deg. Low Side High Side 70 207 72 220 73 235 75 251 76 266 77 283 78 300 79 318 79 337 DB80 deg. WB67 deg. Low Side High Side 75 212 77 226 78 241 80 257 81 273 82 290 83 308 84 326 85 346 DB85 deg. WB72 deg. Low Side High Side 78 219 80 234 81 249 83 266 84 283 85 300 86 319 87 337 88 358 WL484 DB75 deg. WB62 deg. Low Side High Side 73 204 74 217 76 232 78 248 79 265 80 284 82 304 83 325 84 348 DB80 deg. WB67 deg. Low Side High Side 78 210 79 223 81 238 82 254 84 272 86 291 87 312 89 334 90 357 DB85 deg. WB72 deg. Low Side High Side 84 217 85 231 87 247 88 264 90 282 92 302 93 323 95 345 97 369 WL602 DB75 deg. WB62 deg. Low Side High Side 71 233 72 247 74 262 75 278 76 295 77 313 78 331 78 351 79 371 DB80 deg. WB67 deg. Low Side High Side 76 237 78 253 79 269 80 285 81 303 82 321 83 340 84 390 85 381 DB85 deg. WB72 deg. Low Side High Side 84 245 85 261 85 278 86 296 87 314 88 333 89 353 90 373 91 394 Low side pressure ± 2 PSIG High side pressure ± 5 PSIG Tables are based upon rated CFM (airflow) across the evaporator coil. If there is any doubt as to correct operating charge being in the system, the charge should be removed, system evacuated and recharged to serial plate instructions. NOTE: Pressure table based on high speed condenser fan operation. If condensing pressures appear elevated check condenser fan wiring. See “Condenser Fan Operation” on Page 14. Manual 2100-400 Page 17 TABLE 11 OPTIONAL ACCESSORIES Part Number Description WL423-AWL423-BWL423-CWL484-AWL484-BWL484-CWL602-AWL602-BWL602-C BOP-5 BFAD-5 MFAD-5 Blank Off Plate Barometric Fresh Air Damper Motorized Fresh Air Damper X X X X X X X X X X X X X X X X X X X X X X X X X X X CRV-5 Commercial Ventilator with Exhaust X X X X X X X X X EIFM-5 Economizer with Exhaust X X X X X X X X X CMA-6 CMA-10A Low Ambient Control (LAC) LPC + HPC + TDR X X X X X X X X X CMA-13A CMC-15 CMA-16 LPC + HPC + TDR + Alarm Relay Start Kit Low Pressue Control X X X X X X X X X CMA-18 LPC & LAC X X X X X WMCB-05B Circuit Breaker Kit X X WMCD-01C Pull Disconnect Kit X X X WMCB-08A Circuit Breaker X X ...

Otros modelos de este manual:
Los acondicionadores de aire - WL423 (274.93 kb)
Los acondicionadores de aire - WL602 (274.93 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría