|
Resumen del manual
ON/OFF TIMER BUTTONS (OPTIONAL) Used to set the time of starting and stopping operation. (See page 17) TIME SETTING BUTTONS Used to adjust the time. (See page 17) TIMER SET/CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 17) SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation. (See page 17) AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating. (See page 19) ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. PLASMA(OPTIONAL) Used to start or stop the plasma-purification function. (See page 15) HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (NOT ON ALL MODELS) Used to set the desired horizontal airflow direction. (See page 18) RESET BUTTON Used prior to resetting time or after replacing batteries. 2nd F Button Used prior to using modes printed in blue at the bottom of buttons. (See page 16) AUTO CLEAN(OPTIONAL) Used to set Auto Clean mode. 8 Room Air Conditioner Operating Instructions Cooling Operation ON Cooling Healthy Dehumidification Auto Heating (Heat pump model only) To lower the temperature To raise the temperature Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote control. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Close the door on the remote control. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C in 1°C increments. Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps- low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted. 1234Natural wind by the CHAOS logic o For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic. ENGLISH Owner’s Manual 9 Operating Instructions Auto Operation (Optional) ON Cooling Healthy Dehumidification Auto Heating (Heat pump model only) To lower the temperature To raise the temperature Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote control. To select Auto Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you want to change the set temperature, press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will be changed automatically. 123For this operation A 1 appears on the display (Cooling plasma model only) During Auto Operation: o You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule. o If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating mode to cooling mode, it must be done by manually resetting. oDuring Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and down automatically. If you want to stop auto-swing, press the chaos swing button again. 10 Room Air Conditioner Operating Instructions Auto Changeover Operation(Optional) ON Cooling Healthy Dehumidification Auto changeover Heating (Heat pump model only) To lower the temperature To raise the temperature Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote control. To select Auto Changeover Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. During Auto changeover Operation: The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room temperature in ±2°C with respect to setting temperature by auto changeover mode. 12Close the door on the remote control. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C in 1°C increments. Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps- low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted. 34 ENGLISH Owner’s Manual 11 Operating Instructions Healthy Dehumidification Operation ON Cooling Healthy Dehumidification Auto Heating (Heat pump model only) Press the Start/Stop button. The unit will respond with a beep. Open the door on the remote control. To select Healthy Dehumidification Operation, press the Operation Mode Selection button. ...
Otros modelos de este manual:Los acondicionadores de aire - LG-BKE 6450 D, LG-BKE 6500 D, LG-BKE 6600 D, LG-BKE 6700D, LG-BKE 6800 D (967.54 kb)
Los acondicionadores de aire - LG-BKE 6700 D, LG-BKE 6800 D (967.54 kb)