Resumen del manual


To set time to start the machine with the unit off (but power supplied), press” TIMER” button, the LCD window will show” “ press the TIME button, set the time to start as you like. The setting range is 1-12 hour 2. To set time to stop the machine with the unit running, press “TIMER’ button, the LCD window will show”® —OFF’, press the TIME button set the time to stop the machine as you like. The setting range is 1-12 hours. 3. If you have set switch on/off after 12 hours, press this key again then could cancel the timing. AUTO SWING FUNCTION 1. Press the ”SWING” button, the LCD window will show and then begin to swing automatically. 2. Press the “SWING“ button again, the symbol” “in the LCD window will disappear, the swing mode will stop. Attention: If you Press the ”A“ and ”V“ buttons together for more than two seconds the keys will lock, LCD window will show” ~ “,press the two buttons again can unlock the keys, the symbol ”~” will disappear. Portable Air Conditioner Owner’s Manual Portable Air Conditioner Owner’s Manual WATER DRAINAIGE Auto pump water function of water pump WATER DRAINAIGE Auto pump water function of water pump I. Under random mode, if the water level in the water tank is over water level I, the switch of water level I will close, and the water pump will start to work. The main engine will operate under the previous mode. 2. If the water level in the water tank is below water level 1, the switch of water level will disconnect, and the water pump will stop after 2 minutes, and the operation mode for main engine will be unchanged. Water level auto alarm function in water tank In random mode, if the water level in the water tank is over 2. the water level 2 switch will dose and the water full light will illuminate. The buzzer alarm will sound, and the LCD window will indicate failure code E5. The main engine will shut off automatically, and the water pump will stop after 20 minutes. After the water level in the water tank is below I, the switch of water level will disconnect, and without the alarm, the indication of trouble code E5 will disappear. The main engine will resume standby. Portable Air Conditioner Owner’s Manual MAINTENANCE/SERVICE MAINTENANCE METHODS MAINTENANCE/SERVICE MAINTENANCE METHODS 1. Pull the plug out of the socket before cleaning. 2. Make sure there is no power to the unit before beginning maintenance or repair. 3. Do not use chemical solvents (like benzene, alcohol glazer) to clean the surface of the unit, Doing so could scratch, damage, or warp the surface. AIR FILTER If the air filter is blocked with a lot of dust, the air flow volume will be reduced. Clean the filter once every two weeks. Open the air filter 1. Open the air filter cover upwards 2. Take the air filter out of filter cover. Clean Wash the air filter by immersing it gently into warm (about 40°C or 104°F) water with a neutral detergent, rinse the filter of detergent and dry it thoroughly in a shaded place. Mounting 1. Attach the filter to the filter cover with the attachment hooks on the inside surface of the cover. 2. Place the hooks at the bottom of the filter cover into the holes in the case, push it back into its original position. Portable Air Conditioner Owner’s Manual MAINTENANCE & SERVICE MAINTENANCE & SERVICE KEEP SURFACE CLEAN Clean the surface of the unit with a damp cloth, then dry using a dry cloth. STORAGE METHODS END OF SEASON OPERATIONS I. To remove the stopper of continuous water drainage. Then operate the unit in fan mode for half a day until the pipe is dry. 2. Switch off the unit and disconnect the plug from the power supply. 3.Tie the cable with a string. 4. Wrap the machine with the plastic bag, and keep it in a cool, dry place. Portable Air Conditioner Owner’s Manual SAFETY OCCASION SAFETY OCCASION • Do not use the unit in a very narrow room with obstacles. • Do not use the unit in direct sunlight to avoid color fading. • Do not use the unit in water or near water. • Do not use near gas appliances, fires or in the vicinity of flammable liquids. POWER SOURCES • Do not use a damaged or improper NC socket. • When unplugging the unit, hold the power plug securely and pull it out carefully. OTHERS • Keep the unit at least 2-3 feet away from TV sets or radios to avoid the risk of electromagnetic interference. • Do not use with the air outlet close to walls or cover the outlet to avoid overheating. SERIOUS CAUTION • Do not toggle over or incline, if the unit does toggle please unplug at once and seek advice from your dealer. • Do not spray with insecticide or other chemicals as the plastic case may be deformed. FEATURES OF HEATING OPERATION MODE • When the air conditioner heats the room air, the compressor does not work – only the PTC electric tube works. Portable Air Conditioner Owner’s Manual TROUBLESHOOTING TROUBLESHOOTING Before seeking repair or service, please check the following. Trouble Check Action Air Conditioner does not operate at all Is there power? Is the unit plugged in? Did...

Otros modelos de este manual:
Los acondicionadores de aire - PAC 10 (591.63 kb)
Los acondicionadores de aire - PAC 12 (591.63 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría