Resumen del manual
Value outside of ( ) is for electric heat only. See Page 12. MODELS: V(E,H)B42K10 V(E,H)B42K15 V(E,H)B49K15 V(E,H)B49K20 V(E,H)B60K20 V(E,H)B60K25 COOLING DATA: Cooling Cap. 42000 42000 48500 48500 58000 58000 Cooling Power (W) 4500 4500 5500 5500 6450 6450 SEER 9.8 9.8 9.8 9.8 9.9 9.9 Cooling SHR 0.72 0.72 0.69 0.69 0.72 0.72 ELECTRICAL HEAT DATA: Heater Size (KW) 10.0 15.0 15.0 20.0 20.0 25.0 Heating Cap. (Btu/h) 34100 51150 51150 68200 68200 85250 Heating Power (W) 10000 15000 15000 20000 20000 25000 Heating Current (A) 41.6 62.4 62.4 83.2 83.4 104.2 HEAT PUMP DATA: Heating Cap. (Btu/h) 40000 40000 47000 47000 59000 59000 Heating Power (W) 4000 4000 4800 4800 5636 5636 Heating Current (A) 19.0 19.0 22.0 22.0 25.0 25.0 COP 3.0 3.0 3.0 3.0 3.0 3.0 ELECTRICAL DATA: Voltage (V) 230/208 230/208 230/208 230/208 230/208 230/208 LRA - Comp. (A) 104.0 104.0 129.0 129.0 169.0 169.0 Min. Ckt. Amps (A) + (33) 52 (33) 26,52 (40.5) 26,52 (40.5 ) 52,52 (49) 52, 52 (49), 26, 52, 52 Power Connection Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire PHYSICAL DATA: Unit Width (in.) 38.00 38.00 38.00 38.00 45.00 45.00 Unit Depth (in.) 28.00 28.00 28.00 28.00 30.50 30.50 Unit Height (in.) 68.00 68.00 68.00 68.00 77.00 77.00 Shipping Weight (lbs.) 440 440 460 460 540 540 AIRFLOW DATA: Indoor CFM 1400 1400 1400 1400 1800 1800 Fresh Air CFM 70 70 70 70 70 70 Indoor Motor 1/2 1/2 1/2 1/2 1/2 1/2 Indoor Motor Amps 3.0 3.0 3.0 3.0 3.1 3.1 Outdoor Motor 3/4 3/4 3/4 3/4 1/3 (2) 1/3 (2) Outdoor Motor Amps 4.7 4.7 4.7 4.7 5.0 5.0 Section II . Dimensional Data V(E,H)B18,24,30,36 Unit Dimensions (Inches) Figure 1 CONDENSATE DRAIN EXIT 2" ABOVE FLOOR V(E,H)B42, 49 Unit Dimensions (Inches) Figure 2 V(E,H)B60 Unit Dimensions (Inches) Figure 3 V(E,H)B42, 49 Unit Dimensions (Inches) Figure 2 V(E,H)B60 Unit Dimensions (Inches) Figure 3 Section III – Installation Section III . InstallationSection III . InstallationSection III . InstallationSection III . InstallationSection III . Installation TheVert-I-Pak was designed for installation in residential and light commercial applications. These instructions detail a typical method of installation. Figure 4 shows the typical component location and airflow paths through the unit. Units are available in three return air configurations: front "free-return" with disposable filter; front ducted return with 1" duct flange; and left side ducted return with 1" duct flange. See Figure 10 on Page 11. Unit ConfigurationFigure 4 Unit ConfigurationFigure 4 1) INDOOR AND OUTDOOR AIR REQUIREMENTS The indoor and outdoor air systems are designed to operate at specified airflow rates and external static pressures. The supply and return air duct system pressure losses (including filter, louver/grille and registers) must not exceed the listed external static pressures for either the indoor or outdoor air systems. CAUTION: Failure to adhere to indoor air and outdoor air requirements as listed in the following sections will void unit warranty. A. A.A.A.A.A. Outdoor Air System Outdoor Air SystemOutdoor Air SystemOutdoor Air SystemOutdoor Air SystemOutdoor Air System As a completely self-contained system, the Vert-I-Pak unit requires an adequate supply of outdoor air to exchange heat from the outdoor air coil. The outdoor air intake and discharge openings are located on the back side of the unit. The unit may be installed where the outdoor air path runs through the wall of the building directly behind the unit or where the outdoor air intake and discharge paths are ducted separately away from the unit. Figure 9 shows two typical ducted OA designs. CAUTION: To ensure proper operation, the outdoor air intake and discharge air paths must be free and unobstructed. The two air paths must be situated to ensure that the intake and discharge air do not recirculate (also called short-circuit). Figure 5 VPBWP3 . 8/14 Wall Plenum Figure 6 VPBWP4 . 8/14 Wall Plenum For Models • VE/VHB18 • VE/VHB24 For Models • VE/VHB18 • VE/VHB24 • VE/VHB30 • VE/VHB36 Figure 7 VPBWP5 . 8/14 Wall Plenum Figure 8 VPBWP6 . 8/14 Wall Plenum For Models • VE/VHB42 • VE/VHB49 For Model • VE/VHB60 B. ..... Ducted Condenser Air For ducted outside air applications, the combined pressure losses of the intake and discharge air paths must not exceed the external static capabilities of the system at the design airflow (See Table 3). Outdoor Fan Performance Table 1 Model 0.1 0.2 0.3 0.4 0.5 VE/HB18 1300 1180 1100 950 790 VE/HB24 1300 1180 1100 950 790 VE/HB30 1300 1200 1100 1000 810 VE/HB36 1730 1660 1600 1560 1400 VE/HB42 2100 2000 1900 1800 1700 VE/HB49 2600 2500 2400 2300 2100 VE/HB60 2990 2900 2800 2670 2450 Note: Italictype indicates performance outside the required operating window of ± 10% of rated SCFM. Figure 9 Typical Ducted Outside Air Configuration EXHAUST INTAKE EXHAUST CEILING CEILING BACK OF UNIT OUTDOOR AIR INTAKE OUTDOOR OUTSIDE OUTSIDE AIR WALL WALL INT...
Otros modelos de este manual:Los acondicionadores de aire - 000 (516.44 kb)
Los acondicionadores de aire - 18 (516.44 kb)
Los acondicionadores de aire - 30 (516.44 kb)
Los acondicionadores de aire - 36 (516.44 kb)