Iniciar sesión:
Votos - 4, Puntuación media: 4.5 ( )

Manual de usuario Samsung, modelo AQ09FBN

Fabricar: Samsung
Tamaño del archivo: 8.16 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


1 To cancel the On Timer, press the button one or more times until the timer setting disappears. 2 Press the button. Note If you want to turn on the air conditioner before the timer reaches the setting time, press the button. E-23 ENGLISH Setting the Off Timer You can set the Off Timer to turn off the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours. 1 Press the button until the desired time is displayed to set the Off Timer. You can set the time between 0.5 hour and 24 hours. 3 Press the button to complete the setting. Result: . The remaining time is displayed. . The timer indicator stops blinking. . The air conditioner turns off automatically at the appointed time and the Off Timer setting disappears. Example If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours during non-operation: 1. Press the button until ‘2.0 Hr’is displayed. 2. Press the button. 3. Press the button until ‘4.0 Hr’is displayed. 4. Press the button. Note If you would like to turn on the air conditioner and then to turn off it automatically at the appointed time by using On/Off Timer during operation, you should set the On Timer longer than the Off Timer. Caution Make sure that the air conditioner will not continue to run after On Timer setting is confirmed. Note . You can check or change the mode and/or the temperature by pressing the button or the button after setting the Off Timer. . If you would like to turn off the air conditioner and then to turn on it again automatically at the appointed time by using On/Off Timer during non-operation, you should set the Off Timer longer than the On Timer. To Cancel the Off Timer If you no longer wish to use the Off Timer that you have set, you can cancel it at any time. 1 To cancel the Off Timer, press the button one or more times until the timer setting disappears. 2 Press the button. Note If you want to turn off the air conditioner before the timer reaches the setting time, press the button. Operating Your Air Conditioner Without the Remote Control Operating Your Air Conditioner Without the Remote Control E-24 Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken. 1 To switch the air conditioner on, press the ON/OFF switch on the right side of the indoor unit. Result: . The OPERATION indicator on the indoor unit comes on. ...The indoor unit beeps. ...The air conditioner starts up in the most suitable mode for the room temperature. The mode may change from cooling into heating, from heating into cooling depending on the current temperature during operation: Room Temperature Operating Mode Less than 24°C Heat 24°C or above Cool 2 To switch the air conditioner off, press the ON/OFF switch again. Note Even if the air conditioner has been switched on via the ON/OFF switch, operations can still be controlled using the remote control as usual. E-25 ENGLISH Cleaning Your Air Conditioner Cleaning Deodorizing and Bio filter (Option) To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter. IMPORTANT Before cleaning your air conditioner, ensure that you have switched off the breaker used for the unit. 1 Open the upper front grille by pulling the lower right and left tabs of the grille. 2 Pull air filters out of each tab of the grille. 3 Remove all dust on the air filters with a vacuum cleaner or brush. 4 When you finished, insert air filters by fixing it to each tab of the grille. 5 To close the front grille, fix it to hooks and push down the lower right and left tabs of the grille. 6 Clean the front grille with a damp cloth and mild detergent (do NOT use benzene, solvents or other chemicals). Note If you have not used the air conditioner for a long period of time, set the fan going for three to four hours to dry the inside of the air conditioner thoroughly. Front grille Air filter Body groove Body Front grille Hook Body To remove minute dust particles and odors, deodorizing and Bio filter are installed in the air conditioner. You should clean the filters every 3 months. 1 Open the upper front grille by pulling the lower right and left tabs of the grille. 2 Pull out the deodorizing and Bio filter. 3 Wash the filters with clean water, then dry them in the shade. 4 Insert the filters into the original position. Note You can change the position of filters with each other. 5 Close the front grille. Deodorizing Filter Bio Filter E-26 Temperature and Humidity Ranges .If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on the operating condition. If you use the air conditioner in temperatures over 32°C (indoor temperature), the cooling capacity may drop. If you check the following tables, you can use your air conditioner more efficiently. If the air conditioner is used at... Then... Heating capacity The air conditioner may stop operating for the reason o...

Otros modelos de este manual:
Los acondicionadores de aire - AQ09FAN (8.16 mb)
Los acondicionadores de aire - AQ09FAX (8.16 mb)
Los acondicionadores de aire - AQ09FBX (8.16 mb)
Los acondicionadores de aire - AQ18FAN (8.16 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría