|
Resumen del manual
If the desired temperature is lower than 24°C, turn off the Smart Saver function by pressing the Smart Saver button again. Temperature/Fan speed can also be adjusted (see step 3~4 on page 15 for instructions). Air flow can be adjusted manually (see page 19 for instructions). If you press the Mode button while the Smart Saver function is on, it will cancel the function. To deactivate the Smart Saving function. 1. Press the Smart Saver button on the remote control while Smart Saver function is on. Smart Saver function you set will be canceled and Smart Saver indicator will disappear on the remote control display. 26_ using advanced functions cleaning and maintaining the air conditioner_ A Make sure the power is turned off and unplugged from the wall socket when cleaning the air CAUTION conditioner. If system contains 3 kg or more of fluorinated greenhouse gases. In this case, it has to be checked for leakage at least once every 12 months, according to regulation n°842/2006. This activity has to be covered by qualified personnel only. In the case above, a maintenance book has to be available for each unit installed. CLEANING THE EXTERIOR_ 1. Wipe the surface of the unit with a slightly wet or dry cloth when needed. A Do not use Benzene, Thinner or Clorox™. cAutIoN They may damage the surface of the air conditioner and can create a risk of fire. CLEANING THE FILTER_ When cleaning the filter, make sure to unplug the power from the unit. No special tools are needed to clean it. Air filter Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. 1. Open the front panel. Tightly grab front side of the front panel and lift up the panel to open. Then slightly push the panel up until the panel is hanged over the hooks of the unit. 2. Grab the handle and lift It up. Then, pull the Air filter towards you and slide it down. 3. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with running water and dry it in a ventilated area. For the best conditions, repeat every two weeks. If the Air filter dries in a confined(or humid) area, odors may generate. If it occurs, re-clean and dry it in a well-ventilated area. 4. Insert the Air filter back in its original position. 5. Close the front panel. cleaning and maintaining _27 ENGLISH cleaning and maintaining the air conditioner MAINTAINING YOUR AIR CONDITIONER_ If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness. Periodical checks Refer to the following chart to maintain the air conditioner properly. Type Description Every 2 weeks Every 3 months Every 4 months Once a year Indoor unit Clean the air filter (1) • Clean the condensate drain pan (2) • Thoroughly clean the heat exchanger (2) • Clean the condensate drain pipe (2) • Replace the remote control batteries (1) • Outdoor unit Clean the heat exchanger on the outside of the unit (2) • Clean the heat exchanger on the inside of the unit (2) • Clean the electric components with jets of air (2) • Verify that all the electric components are firmly tightened (2) • Clean the fan (2) • Verify that all the fan assembly is firmly tightened (2) • Clean the condensate drain pan (2) • • : This check mark requires checking the indoor/outdoor unit periodically, following to the description to maintain the air conditioner properly. The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner. The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc. (1) The described operations should be performed more frequently if the area of installation is very dusty. (2) These operations must always be performed by qualified personnel. For more detailed information, see the Installation Manual. 28_ cleaning and maintaining Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Description Against cold air The internal fan will be off to against cold air when the heat pump is heating. De-ice cycle The internal fan will be off to against cold air when the heat pump is heating. Anti-protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode. Protect compressor The air conditioner does not start operating immediately to protect the ...
Otros modelos de este manual:Los acondicionadores de aire - AQ09UGBN (13.09 mb)
Los acondicionadores de aire - AQ09UGBX (13.09 mb)
Los acondicionadores de aire - AQ09UGDX (13.09 mb)
Los acondicionadores de aire - AQ12UGAN (13.09 mb)