|
Otros manuales para este modelo:
Resumen del manual
..09/12NSA 10°C~43°C ..09/12NSB ..18/24..-10°C~43°C POWER SUPPLY Single phase rated voltage minimum and maximum limit 220V-240V~50Hz 198V min.-264V max. .....Any damage occurs out of condition specified cannot be covered by product warranty. If the system works continuosly outside of conditions, its performace and reliability will be compromised. Temperature and Humidity Ranges Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Heating performances The heat pump function of the air conditioner absorbs heat from outside air and brings it indoors. As the temperature of the outside air drops, the heating performance of air conditioner will decrease. If you find that the room is not warm enough, using an additional heating appliance is recommended. Warm air circulation The air conditioner circulates warm air to heat your room. It will take some time to warm the air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on in advance. Frost When outdoor temperature is low but humidity is high, frost may form on the outdoor unit at Heat mode. ..The heating operation stops. ..The defrost mode will be triggered automatically for 3 to 14 minutes. No intervention is required ; after about 7 minutes, the air conditioner operates again normally. High indoor and outdoor temperatures If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT mode, the outdoor unit’s fan and compressor may stop at times. This is normal;simply wait until the air conditioner switches on again. Power failure If a power failure occurs while the air conditioner is operating, the unit will be switched off. When the power returns, the air conditioner starts up again automatically. Protection mechanism When the air conditioner is started immediately after being plugged in or stopped, the normal operation starts up after 3 minutes for the reason of protection. Cooling operation The indoor unit may not get the selected fan speed such as Medium and Low under cooling operation at very low outdoor temperatures for the protection of the indoor unit from ice or frost. During Low fan speed operation, cooling performance will be reduced. If the room does not be cooled down when using Low fan speed operation, please adjust the indoor unit’s fan speed. Silence Mode When you operate Silence Mode in cooling and heating, fan speed will decrease to make noise quieter. As a result, the performance of the unit may be reduced. The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE OPERATING CONDITIONS IF OUT OF CONDITIONS COOL Indoor temp: 16°C~32°C - A safety device will stop continuously the system functioning; - Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor; Indoor humidity: below 80% Outdoor temp: ...
Otros modelos de este manual:Los acondicionadores de aire - AQ09BAX (7.67 mb)
Los acondicionadores de aire - AQ09ESAN (7.67 mb)
Los acondicionadores de aire - AQ09ESAX (7.67 mb)
Los acondicionadores de aire - AQ09NSDN (7.67 mb)