|
Resumen del manual
They may save you the time and expense of an unnecessary call. E-12 Air the room.Odours are permeated in the room during air conditioning Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. E-12 Design and specifications are subject to change without notice. Model Power Supply .......BA/BB/BC/BD/BE 220V(230V)~, 60Hz .......DA 200-220V~, 50Hz .......EA/EB 220-240V~, 50Hz Installation (for 60Hz) 1 Electrical Requirements For personal safety: This appliance must be properly grounded. Do not, under any circumstances, cut or remove the third grounding prong from the power cord. We recommend that you do not use an extension cord or an adapter plug with this appliance. Do not change the plug on the power cord of this appliance. Follow national electrical codes or local codes and ordinances. 115V 230V/208V 230V/208V 230V/208V 15 AMP circuit 20 AMP circuit 15 AMP circuit 30 AMP circuit "parallel" type "perpendicular" type "tandem" type "tandem" type If the electric supply provided does not meet the above specifications, call a licensed electrician. Aluminum house wiring may pose special problems - consult a qualified electrician. This unit requires a separate circuit, serving only this appliance. E-13 ENGLISH Before installation, be sure to check the installation area or the air conditioner, and drain hose. Checkpoints prior to installation Installation 500mm 750mm E-14 The appliance must be fixed well by screw or similar method. 1 Check the cabinet and front grille of the unit for any harmful defects such as scratches. 2 Be sure to check the power supply. -Refer to the specifications on the label attached to the unit. Installation Conditions 1 As the unit is heavy, the wall or window of the installation area should have sufficient strength and durability for operation of the air conditioner, and for prevention of any vibration or noise. If it is weak, reinforcement work should be performed separately. 2 It is advisable to install the air conditioner in the north or west side to prevent the effect of direct sunlight. When installing it in the south or east side due to unavoidable circumstances, it is advisable to install the sunshade to prevent the direct sunlight. In this case, take care not to cause any hindrance to the flow of outside air. 3 When installing the air conditioner, be sure to obtain sufficient space on the rear side of the unit for smooth flow of air. When operating the air conditioner in closed areas such as inner building with cooling operation, and result in trouble with the unit. See the illustration below. 500mm 75mm min. 300mm 500mm Fence, wall or other obstacle 150mm min. “A” Approx.3° Awning . If the wall is greater than 150mm thick, cut the wall back on a 45° angle if possible. 100mm or more 45°45° Model ......N.. ......D.. ......M.. “A” 180mm 220mm 240mm Outdoor Side Indoor Side In some region, drain tube and drain pan may not be supplied. Please contact the sales agent. Installation of the Drain Tube Fix the drain tube as shown in the figure. Rubber cap Screws(2EA) Gasket Drain Tube Rear Installation of the Drain Pan The procedure for installing the drain pan should be determined by the condition of the installing area. In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner. Example: High storage 1 Open the front grille ; refer to page 10 or 11. 2 Remove the screw located at the lower section of the front grille. It is secured in the section depending on the model. 3 Remove the front panel. 3-1 Press both sides of the cabinet in the direction of the arrow as shown in the figure. 3-2 Pull the lower part of the front panel slightly forward. (below three inches) 3-3 Lift the front panel upward. Applying excessive force to remove the front panel may cause . damage to the tab ; be sure not to use excessive force. 4 Remove two screws on the lower, right and left sides of the unit. 5 Remove the chassis from the cabinet. 6 Remove the rubber cap inserted into the basepan. 7 Fix the drain pan as shown in the figure, and then connect the drain hose. (You can use any commercially-available drain hose.) 8 Install the cabinet at the specified area after installing the drain pan, and then re-assemble it in the original condition. . Secure the front panel to the case by replacing the screw removed in step 2. If a screw not removed in step 2, secure the panel with a supplied screw. Front panel Screw Rubber capDrain Hose Bottom-Side View with Drain Pan and Hose in Place Rear Drain Pan Screw ENGLISH In the case of an area where the drain pan can be directly installed on the rear side of the unit after installing the air conditioner. 1 Follow steps 6 and 7 only E-15 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE ACONDICIONADOR DE AIRE HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: ESTE APARELHO DE AR CONDICIONADO E F...
Otros modelos de este manual:Los acondicionadores de aire - AW07A2NEC (772.2 kb)
Los acondicionadores de aire - AW07F2NBB (772.2 kb)
Los acondicionadores de aire - AW07F2NDA (772.2 kb)
Los acondicionadores de aire - AW07G2NEA (772.2 kb)