|
Resumen del manual
• Aerate the room regularly. Outdoor Unit • Do not insert your fingers or other objectsinto the unit. REGULATORYINFORMATIONREGULATORY INFORMATION REGULATORYINFORMATIONREGULATORY INFORMATION Thank you for purchasing Air Conditioner The appliance is not intended for use by young children or the infirm person without supervision. Young children should be supervised to ensure that they do not play with the appliance. OPERATION CONDITIONOPERATION CONDITION Use this air conditioner under the following temperature range Temperature (°C) Indoor Outdoor *DBT *WBT *DBT *WBT COOLING Maximum 32 23 43 26 Minimum 16 11 16 11 * DBT: Dry bulb temperature * WBT: Wet bulb temperature Replacement or installation of power plugs shall be performed by authorized/ qualified personnel only. The wires in this mains lead are coloured in accordance with the following code: Terminals wires live neutral colours (GB Standard) brown blue red black green-yellowearthgreen/yellow Wiring colour may vary depending on a country wiring code’s standard. ENGLISHTABLE OF CONTENTSTABLE OF CONTENTS NOTE :NOTE : SAFETY PRECAUTIONS 2 REGULATORY INFORMATION 3 PRODUCT OVERVIEW & OPERATIONS 4~5 CARE & CLEANING 6 TROUBLESHOOTING 7 QUICK GUIDE BACK COVER The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement. ENVIRONMENTAL REQUIREMENTS Battery Disposal The batteries must be recycled or disposed of properly. END-OF-LIFE DISPOSAL “Instructions for end-user” for air conditioners: Information on Disposal in other countries outside the European Union This symbol is only valid in the European Union. If you wish to discard this product, please contact your installer, dealer or local authority and ask for the correct method of disposal. • • Do not switch ON the unit when waxing the floor. After waxing, aerate the room properly before operating the unit. Do not install the unit in oily and smoky areas. 4 PRODUCT OVERVIEW & OPERATIONS Remote control display Front panel Receiver Auto OFF/ON button • Used when remote control is misplaced or malfunction. Action Mode Press once. Auto Press and hold until 1 beep is heard, then release. Cooling Press the button to turn off. Airfl ow direction louver • Do not adjust by hand. e-ion AIR PURIFYING SYSTEM Do not touch during operation e-ion fi lters Active e-ion Power Module Active e-ion Generator Maximum distances: 8m TO TURN ON OR OFF THE UNIT • Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly. TO SET TEMPERATURE • For cool and dry modes, the range of temperature for selection is 16°C ~ 30°C. • Operating the unit within the recommended temperature could induce energy saving. COOL mode : 26°C ~ 28°C. DRY mode : 1°C ~ 2°C lower than room temperature. TO SELECT OPERATION MODE AUTO mode - For your convenience • Unit selects the operation mode according to the room temperature. • Once auto mode is selected, the unit will operate at the standard setting temperature. • To change the standard setting temperature, press for “HI” or for “LO”. Room temperature Operation mode Standard setting temperature HI (+2°C) LO (-2°C) 23°C & above Cool 25°C 27°C 23°C Below 23°C Dry 22°C 24°C 20°C COOL mode - To enjoy cool air DRY mode - To dehumidify the environment • Unit operates at low fan speed to give a gentle cooling operation. INDICATOR (Green) (Orange) (Orange) (Orange) (Blue) ENGLISH TOTO SET THE TIMERSET THE TIMER • To turn ON or OFF the unit at a preset time. .......... Select ON or OFF timer. Set the time. Confirm. • To cancel ON or OFF timer, press or then press . • When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time. • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. • If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is resumed) by pressing . TO SELECT FAN SPEED (3 OPTIONS) • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. TO ADJUST AIRFLOW DIRECTION (5 OPTIONS) • Keeps the room ventilated. • If AUTO is set, the louvers swing left/right and up/down automatically. TO ENJOY CLEAN & FRESH AIR • Generates negative ions to produce fresh air effect and attract dust which will then be captured at thepositively charged e-ion filters. TO MONITOR AIR QUALITY Indicator Air Quality BlueCleanOrangeModerateRedDirty• Patrol sensor detects air quality. • When air quality is at dirty level, e-ion operation will startautomatically. TO ENJOY QUIET ENVIRONMENT • This operation reduces airfl ow noise. TO ACHIEVE TEMPERATURE QUICKLY • This operation will stop automatically after 15 minutes. • , , and can be activated in all modes and can be cancelled by pressing the...
Otros modelos de este manual:Los acondicionadores de aire - CS-C18HKD (1.86 mb)
Los acondicionadores de aire - CU-C18HKD (1.86 mb)
Los acondicionadores de aire - CU-C24HKD (1.86 mb)
Los acondicionadores de aire - CSC18HKD (1.86 mb)