Iniciar sesión:
Votos - 4, Puntuación media: 4.5 ( )

Manual de usuario Samsung, modelo AC052FBMSEH

Fabricar: Samsung
Tamaño del archivo: 1.35 mb
Nombre del archivo:
Idioma del manual:
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


Verify that all the electric components are firmly tightened (2) . Clean the fan (2) . Verify that all the fan assembly is firmly tightened (2) . Clean the condensate drain pan (2) . cleaning and maintaining the air conditioner MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness. Periodical checks Refer to the following chart to maintain the air conditioner properly. Type Indoor unit Outdoor unit The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner. The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc. (1) The described operations should be performed more frequently if the area of installation is very dusty. (2) These operations must always be performed by qualified personnel. For more detailed information, see the Installation Manual. 14_ cleaning and maintaining the air conditioner Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Against cold air De-ice cycle Anti-protection of internal battery Protect compressor Description The internal fan will be off to against cold air when the heat pump is heating. The internal fan will be off to against cold air when the heat pump is heating. The compressor will be off to protect internal battery when the air conditioner operates in Cool mode. The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started. ENGLISH If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures. The internal fan is switched off automatically and restarted only after the de-ice cycle is completed. cleaning and maintaining the air conditioner _15 appendix TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM The air conditioner does not operate immediately after it has been restarted. The air conditioner does not work at all. The temperature does not change. The cool (warm) air does not come out of the air conditioner. The fan speed does not change. Timer function does not set. Odors permeate in the room during operation. The air conditioner makes a bubbling sound. Water is dripping from the air flow blades. Remote control is not working. The air conditioner does not turn on o...

Otros modelos de este manual:
Los acondicionadores de aire - AC100FBMSEH (1.35 mb)
Los acondicionadores de aire - AC100FBMDEH (1.35 mb)
Los acondicionadores de aire - AC090FBMSEH (1.35 mb)
Los acondicionadores de aire - AC090FBMDEH (1.35 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría