Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Samsung, modelo AC026FCADEH

Fabricar: Samsung
Tamaño del archivo: 871.32 kb
Nombre del archivo:
Idioma del manual:
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


Children should be supervised to ensure that they do not play with the appliance. FOR CLEANING WARNING Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the appliance. . This may result in discoloration, deformation, damage, electric shock or fire. Before cleaning or performing maintenance, unplug the air conditioner from the wall socket and wait until the fan stops. . Failing to do so may result in electric shock or fire. FOR CLEANING CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges. . To avoid cutting your fingers, wear thick cotton gloves when cleaning it. Do not clean the inside of the air conditioner by yourself. . For cleaning inside the appliance, contact your nearest service center. . When cleaning the internal filter, refer to the descriptions in the ‘Cleaning and maintaining the air conditioner’ section. . Failure to do may result in damage, electric shock or fire. Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE OUTDOOR TEMPERATURE INDOOR TEMPERATURE INDOOR HUMIDITY COOLING 2.6kW -10°C/14°F to 46°C/115°F 18°C/64°F to 32°C/90°F 80% or less 3.5kW 5.2kW -15°C/5°F to 46°C/115°F 6.0kW 7.1kW -15°C/5°F to 50°C/122°F HEATING 2.6kW -15°C/5°F to 24°C/75°F 27°C/81°F to less 3.5kW 5.2kW 6.0kW -20°C/-4°F to 24°C/75°F 7.1kW DRYING 2.6kW -10°C/14°F to 46°C/115°F 18°C/64°F to 32°C/90°F 3.5kW 5.2kW -15°C/5°F to 46°C/115°F 6.0kW 7.1kW -15°C/5°F to 50°C/122°F • The standardized temperature for heating is 7.C/45.F. If the outdoor temperature drops to /32.F or below, the heating capacity can be reduced depending on the temperature condition. If the cooling operation is used at over 32.C/90.F (indoor temperature), it does not cool at its full capacity. • The use of the air conditioner at a relative humidity above the expected one (80%) may cause the formation of condensate and the leakage of water drops on the floor. NOTE Model : RJ... Mode Outdoor temperature Indoor temperature Indoor humidity If out of conditions Cooling -5.C/23.F ~46.C/115.F 16.C/61.F~32.C/90.F 80% or less Condensation may occur on the indoor unit with risk to have either water blow off or drop on the floor. Heating -15.C/5.F~24.C/75.F 27.C/81.F or less - Internal protection triggers and the air conditioner will stop. Dry -5.C/23.F~46.C/115.F 18.C/64.F~32.C/90.F - Condensation may occur on the indoor unit with risk to have either water blow off or drop on the floor. • The standardizedtemperature for heating is 7.C/45.F. If the outdoor temperature drops to 0.C/32.F or below, the heatingca...

Otros modelos de este manual:
Los acondicionadores de aire - AJN016NDEHA/EU (871.32 kb)
Los acondicionadores de aire - AJN020NDEHA/EU (871.32 kb)
Los acondicionadores de aire - AJN026NDEHA/EU (871.32 kb)
Los acondicionadores de aire - AJN035NDEHA/EU (871.32 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría