Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Samsung, modelo AM022FNQDEH/EU

Fabricar: Samsung
Tamaño del archivo: 4.7 mb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


Model specification (Dimension and weight) Dimension and weight Type Model Net dimension (WxDxH) (mm) Net weight (kg) Type Model Net dimension (WxDxH) (mm) Net weight (kg) Indoor unit AM022FNTDEH/EU 825*285*189 8.5 Outdoor unit (DVM S HR_NASA) AM080FXVAGR/EU 880*765*1695 195 AM028FNTDEH/EU 825*285*189 8.5 AM100FXVAGR/EU 880*765*1695 195 AM036FNTDEH/EU 825*285*189 8.5 AM120FXVAGR/EU 880*765*1695 195 AM045FNLDEH/EU 1065*298*218 12.5 AM140FXVAGR/EU 1295*765*1695 241 AM071FNTDEH/EU 1065*298*218 12.5 AM160FXVAGR/EU 1295*765*1695 284 AM022FNQDEH/EU 825*285*189 8.8 AM180FXVAGR/EU 1295*765*1695 306 AM028FNQDEH/EU 825*285*189 8.8 AM200FXVAGR/EU 1295*765*1695 306 AM036FNQDEH/EU 825*285*189 8.8 AM220FXVAGR/EU 1295*765*1695 306 AM045FNQDEH/EU 1065*298*218 13 Outdoor unit (DVM S HP_NASA) AM080FXVAGH/EU 880*765*1695 190 AM056FNQDEH/EU 1065*298*218 13 AM100FXVAGH/EU 880*765*1695 190 AM071FNQDEH/EU 1065*298*218 13 AM120FXVAGH/EU 880*765*1695 190 AM140FXVAGH/EU 1295*765*1695 235 AM160FXVAGH/EU 1295*765*1695 278 AM180FXVAGH/EU 1295*765*1695 300 AM200FXVAGH/EU 1295*765*1695 300 AM220FXVAGH/EU 1295*765*1695 300 Outdoor unit (DVM MINI NASA) AM040FXMDEH/EU 940*330*1210 100 AM050FXMDEH/EU 940*330*1210 100 AM060FXMDEH/EU 940*330*1210 103 AM040FXMDGH/EU 940*330*1210 100 AM050FXMDGH/EU 940*330*1210 100 AM060FXMDGH/EU 940*330*1210 103 Installation Part Performing Leak Test & Insulation Leak test Fixing the Installation Plate LEAK TEST WITH NITROGEN(before opening valves) In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R410A, it’s responsible of installer to pressurize the whole system with nitrogen(using a pressure regulator) at a pressure above 4.1MPa(gauge). LEAK TEST WITH R410A(after opening valves) Before opening valves, discharge all the nitrogen into the system and create vacuum. After opening valves check leaks using a leak detector for refrigerant R410A. Before fixing the installation plate to the wall or window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. When facing the wall, the pipe and cable can be connected from the: . Right . Left . Underside(right) . Rear(right or left) D C g The designs and shape are subject to change according to the model. 1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards. 2. If you fix the indoor unit to a...Follow step(s)... Wall3. Window frame4 to 6. 3. Fix the installation plate to the wall giving attention to the weight of the indoor unit. . If you mount the plate to a concrete wall with anchor bolts, the anchor bolts must not project more than 20mm. 4. Determine the positions of the wooden uprights to be attached to the window frame. 5. Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit. Discharge all the nitrogen to create a vacuum and charge the system. Insulation After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. 1. To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit. 2. Wrap the refrigerant pipe and the drain hose in the rear of the indoor unit with the absorbent pad. . Wind the pipe and hose three times to the end of the indoor unit with the absorbent pad. (20mm interval) 3. Wind the pipe, assembly cable and drain hose with insulation tape. 6. Attach the installation plate to the wooden uprights using tapping screws as seen in the picture. (Unit : mm) ..022/028/036.. 120726872 4. Place the bundle(the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it doesn’t project from the rear of the indoor unit. 5. Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place. 6. Wrap the rest of the pipe with vinyl tape. Pipe hole (O65mm) (Unit : mm) ..045/056/071.. 140346834 Pipe hole (O65mm) 7. Attach the pipe to the wall using clamps(optional). Installing and Connecting the Drain Hose of the Indoor Unit When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65mm hole drilled in the wall, check the following: The hose must NOT slant upwards. The end of the drain hose must NOT be placed under water. Installation plate 8. Select the insulation of the refrigerant pipe. . Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size. . The thickness according to the pipe size is a standard of the indoor temperature of 27°C and humidity of 80%. If installing in an unfavorable conditions, use thicker one. . Insulator’s heat-resistance temperature should be more than 120°C. Do NOT bend the hose in different directi...

Otros modelos de este manual:
Los acondicionadores de aire - AM028FNQDEH/EU (4.7 mb)
Los acondicionadores de aire - AM028FNTDEH/EU (4.7 mb)
Los acondicionadores de aire - AM036FNQDEH/EU (4.7 mb)
Los acondicionadores de aire - AM036FNTDEH/EU (4.7 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría