Iniciar sesión:
Votos - 3, Puntuación media: 4.7 ( )

Manual de usuario DeLonghi, modelo PAC 02

Fabricar: DeLonghi
Tamaño del archivo: 990.72 kb
Nombre del archivo: 4035f3af-aded-474d-82d0-8f15e8676fd2.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


turn the dial in a clockwise direction (following the direction of the arrow) until the number 4 is lined up with the arrow pointer (the arrows indicates 4;00 p.m. approximately). Note:Never turn the dial in an anti-clockwise direction! The timer is in effect, an electric clock and works only if the plug is connected to the power supply Whenever the plug is disconnected or there is a power failure, the programmer stops (the clock is then "slow'1') and must be re-set. The unit can be used in either programmed or non-programmed mode PROGRAMMED MODE 1) Press the timer ON/OFF button 2) Set the operating times by pushing out the notches on the dial corresponding to the period required (each notch represents 15 rrans ) 3) Check that the timer indicates the correct time (see instructions on setting). The unit will now switch on and oft each operating lune- day at the selected times, Note: To override the programmed operating times, simply release the ON/OFF key. NON-PROGRAMMED MODE I) TIMER ON/OFF button must be released AIR-CONDITIONING 1 Press the ON-OFF button (J) to start the appliance 2. Set thermostat knob at max. cold. 3. Choose desired temperature. For universal consumer convenience, the temperature is shown by spaced marks rather than in degrees It is recommended that the thermostat be placed on max. cold until room temperature has reached the desired level of comfort, then slowly turn the thermostat knob clockwise until the thermostat shuts off the compressor while vernation continues in so doing you will have programmed your appliance on to this exact level of comfort which the thermostat will automatical maintain. After an initial period of use, consumers will be able to judge immediately the required setting for reaching the temperature desired in a room. SWITCHING OFF 1 To turn the the appliance off. press ON/OFF button © With the appliance on cooling, air humidity in the room is automatically reduced and condensate eliminated through the exahust hose MAINTENANCE PRECAUTIONS tig. 14 lg 15 During cleaning and norma) maintenance operations remember to disconnect plug Under no circumstances should appliance be washed with running water. Damage could be caused to the electrical circuit. CLEANING OF EXTERNAL HOUSING fig. 16 i'g 17 Clean with a damp cloth and dry thoroughly with a clean dry cloth. Use only mild soap arid water. Do not use chemical cleaners CONTROLS AT THE BEGINNING OF THE SEASON Carefully follow installa- Check for any defects in tion procedure. power cord and plug, fig 18 1) AIR FILTER CLEANING Maintenance of air filter A clcggcd air filter reduces the quantity of circulating air and the efficiency of the appliance. Clean filter every week using a vacuum cleaner. Removal and replacement of air filter Gentfy pull filter upwards. Push down to replace. Remove dust with a vacuum cleaner Rinse wilh running waler fig 21 Cleaning procedure To remove dust deposited on filter, use a vacuum cleaner, II it is very dirty, soak in lukewarm water and rinse thouroghly The temperature of the water must be kept below 1043F (40f,C). After washing, leave filter to dry before replacing END OF SEASON OPERATIONS 5) Cover appliance with a polyethylene bag to prevent dust from entering. You can use the polyethylene bag included into the packaging, 1) 2) 3) 4} Disconnect plug. Remove plug from drainage tube, to empty water collecting tray Remove exhaust hose Clean filler and dry well before replacing. TROUBLESHOOTING PROBLEMS CAUSE SOLUTION The Pingüino does not work: power failure plug is disconnected ON/OFF switch is off Timer button is in ON position insert plug switch on release the TIMER key The appliance functions for only brief periods because reset switch activates exhaust hose blocked exhaust hose twisted or bent ventilation holes on the rear of the machine or Front louvers blocked condenser fan has jammed safety bail cock has activated Check for obstruction of air outlet vent eliminate irregularities remove obstacles to allow proper airflow Cal1 Service Centre □rain off cortdansate water through drainage tube ON/OFF switch keeps activating Turn off and call Service Centre The Pingüino produces cold air but room does not maintain comfortable temperature: window open air exhaust hose has become disconnected thermostat set too low air filler blocked source of heal in room (heater, lamp, etc ) or room is overcrowed with people - close window - re-insert exhaust hose - set thermostat to higher num ber - clean filter - remove source of heat SERVICING In case of mallunction turn off and disconnect the Pinguino from power outlet and contact our Service Centre for qualified assistance, toll-free number 1-R00-32?-3848 (Should troubleshooting checklist fail to remedy malfunction, manufacturer does advise customers against unqualified servicing). 13 LIMITED WARRANTY We warrant each DE’LONGHI AlR-CONOlTIONER to be free from...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría