The unit will now switch on and off each day at the selected times. Note: To override the programmed operating times, simply press the ON/OFF key. NON-PROGRAMMED MODE 1) B TIMER button must be pressed 2) Select the desired function as shown in the chart on the following page. 11 9 4 10 arrow pointer 11 10 9 4 OFpunezraiotninagm etinmtoe N.B: For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness. We therefore recommend that when starting up the appliance, the thermostat be turned to maximum (thick green line = maximum cold). When the desired temperature has been reached, turn the thermostat slowly away from the maximum cooling position until the appliance switches off. Leave the thermostat in this position. The air-conditioner is now programmed to maintain the exact temperature at all times. After switching the appliance off, wait at least 3 min. before switching on again. eg. from 9 to 11 a.m. HOW TO START UP THE CONDITIONER (see control panel on the previous page) Plug the appliance into the mains. Select the “programmed” or “non programmed” mode (see previous page) Select the fan speed required pressing “Fan speed” key C. Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. Cold. Press key A (ON/OFF). ON/OFF signal lamp (conditioning) will come on. The appliance comes on. If not, refer to page 14. To switch off the appliance, press key A (ON/OFF main switch). AIR-CONDITIONING 12 MAINTENANCE PRECAUTIONS During cleaning and normal maintenance operations remember to disconnect plug. Under no circumstances should appliance be washed with running water. Damage could be caused to the electrical circuit. CLEANING OF EXTERNAL HOUSING .... .... QQ QQ .. .. Clean with a damp cloth and dry thoroughly with a clean dry cloth. Use only mild soap and water. Do not use chemical cleaners. CONTROLS AT THE BEGINNING OF THE SEASON Carefully follow installation procedure. Check for any defects in power cord and plug. fig. 14 fig. 15 fig. 16 fig. 17 fig. 18 13 AIR FILTER CLEANING Maintenance of air filter A clogged air filter reduces the quantity of circulating air and the efficiency of the appliance. Clean filter every week using a vacuum cleaner. Removal and replacement of air filter Gently pull filter upwards. Push down to replace. Cleaning procedure To remove dust deposited on filter, use a vacuum cleaner. If it is very dirty, soak in lukewarm water and rinse thoroughly. The temperature of the water must be kept below 104°F. After washing, leave filter to dry before replacing. END OF SEASON OPERATIONS 1) Disconnect plug. 2) Remove plug from drainage tube to empty water collecting tray. 3) Remove exhaust hose. 4) Clean filter and dry well before replacing. 5) Cover appliance with a polyethylene bag to prevent dust from entering. You can use the polyethylene bag included into the packaging. fig. 19 Remove dust with a vacuum cleaner Rinse with running water fig. 20 fig. 21 fig. 22 fig. 23 TROUBLESHOOTING SYMPTOMS CAUSE SOLUTION The Pinguino does not -power failure function: -plug is disconnected -insert plug -ON/OFF switch is off -switch on -Timer key is in STOP position -release the TIMER key The Pinguino does not function -function fault warning -exhaust hose blocked -Check for obstruction of air light is on (page. 10 outlet vent “Alarm” light) -exhaust hose twisted or bent -eliminate irregularities After correcting problem, press reset button (see page. 5) -ventilation holes on the rear of the machine or front louvers blocked -remove obstacles to allow proper airflow The Pinguino produces -window open -close window cold air but room does -air exhaust hose has become -re-insert exhaust hose not maintain comfortable disconnected temperature: -thermostat set too low -set thermostat to higher number -air filter blocked -clean filter SERVICING In case of malfunction turn off and disconnect the Pinguino from power outlet and contact our Service Centre for qualified assistance, toll-free number 1-800-322-3848. FOR UNITED STATES ONLY: LIMITED WARRANTY We warrant each DeLonghi AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR-CONDITIONER is used in accordance with the factory directions which accompany it, and on Alternating Current (AC) circuit. This warranty is in lieu of all other warranties and representations, expressed or implied, and all other obligations or liabilities on our part. We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIRCONDITIONER. This warranty shall not apply to assume for us any liability in connection with the sale or use of our AIR-CONDITIONER. This ...