Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario LG, modelo A2UC243FA0 (LMU240CE)

Fabricar: LG
Tamaño del archivo: 8.01 mb
Nombre del archivo: 74efb757-53ca-4692-b4b7-e940b111f303.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


See the page "Combination Table" 2. Due to our policy of innovation some specifications may be changed without notification. Service Manual 13 Product Specifications Outdoor Unit -Multiple piping models Model A2UC243FA0(LMU240CE) A2UH243FA0(LMU240HE) Cooling Capacity Btu/hr 9,000~24,000 9,000~24,000 W 2637~7033 2637~7033 kcal/hr 2267~6037 2267~6037 Heating Capacity Btu/hr -9,000~24,000 W -2637~7033 kcal/hr -2267~6037 Input Cooling W 1170~2390 1170~2390 Heating W -1220~2440 Running Current(208/230V) Cooling A 7.7~10.1 7.7~10.1 Heating A -7.4~9.8 Power Supply O,V,Hz 1,208/230,60 1,208/230,60 Max. Number of Connectable Indoor Units 2 2 Compressor (Constant) Type Rotary Rotary Model GK094K GK094K Motor Type Hermetic Hermetic Quantity Ea 1 1 Motor Input W 955 955 Oil Charge cc 330±10 330±10 Oil Type FVC68D FVC68D Capacitor .F/Vac 30 / 370 30 / 370 O.L.P Type(model name) External Type(MRA98996-12026) External Type(MRA98996-12026) Compressor (Constant) Type Rotary Rotary Model GK141K GK141K Motor Type Hermetic Hermetic Quantity Ea 1 1 Motor Input W 1430 1,430 Oil Charge cc 350±10 350±10 Oil Type FVE FVE Capacitor .F/Vac 35 / 370 35 / 370 O.L.P Type(model name) External Type(MRA12105-12026) External Type(MRA12105-12026) Refrigerant charge Charge g(oz) 1600 1600 Type R410A R410A Control L.E.V L.E.V Coil Tube Size (OD) inch(mm) 0.276(7.0) 0.276(7.0) Fins per inch 18 18 No.ofRows&Column/No. 2R,36C 2R,36C Fan motor Model IC-1640LG GE IC-1640LG GE Output W 90 90 Capacitor .F/Vac 6/370 6/370 Fan Type Propeller Propeller No. Used / Diameter EA/inch(mm) 1 / 460 1 / 460 Discharge Side / Top Side Side Air Circulation Outdoor CMM(CFM) 53(1872) 53(1872) Noise Level(H/L) at 230V Sound Press,1m dB(A) 1 54 54 Defrosting -Invertion Cycle SVC Valve Liquid inch(mm) 1/4 (6.35) * 2EA 1/4 (6.35) * 2EA Gas 3/8 (9.52) * 2EA 3/8 (9.52) * 2EA Dimensions W*H*D inch(mm) 34.3*31.5*12.6 (870*800*320) 34.3*31.5*12.6 (870*800*320) Net Weight Outdoor kg(lbs) 69(152) 69(152) Max. Interunit Piping Length Total of Each Room m 30 30 For One Room m 15 15 Max. Installation Height Difference Indoor Unit~Outdoor Unit m 7.5 7.5 Indoor Unit~Indoor Unit m 7.5 7.5 Packing Dimension W*H*D inch(mm) 40.2*34.3*17.3 (1020*870*440) 40.2*34.3*17.3 (1020*870*440) Testing Combinations SE 12K+SE 12K SE12K +SE12K Stuffing Quantity 20/40ft 54/114 54/114 Notes: 1. Capacities are based on the following conditions: Cooling: -Indoor Temperature 26.7°C(80.1°F)DB/19.4°C66.9°F)WB -Outdoor Temperature 35°C(95°F)DB/23.9°C(75°F)WB -Interconnecting Piping Length 7.5m -Level Difference of Zero. Heating: -Indoor Temperature 21.1°C(70°F)DB/15.6°C(60.1°F)WB -Outdoor Temperature 8.3°C(46.94°F)DB/6.1°C(42.98°F)WB -Interconnecting Piping Length 7.5m -Level Difference of Zero. 2. Capacities are Net Capacities. 3. : See the page "Combination Table" 4. Due to our policy of innovation some specifications may be changed without notification. 14 Multi type Air Conditioner Service Manual 15 Installation Installation Type "A" screw and plastic anchor Type "B" screw Remote Control Holder Installation plate Figure Name Figure Screw driver Electric Drill Measuring Tape, Knife Hole Core Drill Spanner Torque wrench Ohmmeter Hexagonal wrench Ammeter Gas Leak Detector Thermometer, Level Flaring Tool Set Name Installation Parts Installation Tools Read carefully, and then follow step by step. Installation Select the best ocation Indoor unit 1. Do not have any heat or steam near the unit. 2. Select a place where there are no obstacles in front of the unit. 3. Make sure that condensation drainage can be conveniently routed away. 4. Do not install near a doorway. 5. Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles. 6. Use a stud finder to locate studs to prevent unnecessary damage to the wall. CAUTION: Install the indoor unit on the wall where the height from the floors more than 2.3m(7.5ft). Outdoor unit 1. If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted. 2. Ensure that the spaces indicated by arrows around front, back and side of the unit. 3. Do not place animals and plants in the path of the warm air. 4. Take the air conditioner weight into account and select a place where noise and vibration are minimum. 5. Select a place so that the warm air and sound from the air conditioner do not disturb neighbors. Rooftop Installations: If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting. More than 5cm (2.0 inch) More than 5cm (2.0 inch) More than 2.3m (90.6 inch) More than 5cm (2.0 inch) More than 10cm More than 50cm More than 2m More than 50cm more than 70cm (27.6 inch) more than 20cm (7.9 inch) more than 20cm (7.9 inch) 16 Multi type Air Conditioner Installation Piping length and elevation Multi Piping Type Capacity(Btu...

Otros modelos de este manual:
Los acondicionadores de aire - A2UH243FA0(LMU240HE) (8.01 mb)
Los acondicionadores de aire - AMNC093APM0(LMAN090CNS) (8.01 mb)
Los acondicionadores de aire - AMNC123DEA0 (LMN120CE) (8.01 mb)
Los acondicionadores de aire - AMNH093APM0(LMAN090HNS) (8.01 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría