The drain pipe should be installed within 300mm to 550mm from the flexible hose and then lift down 20mm or more. 2. Install horizontal drainpipe with a slope of 1/100 or more and fix it by hanger space of 1.0~1.5m. 3 Install the air vent in the horizontal drainpipe to prevent water flow back to the indoor unit. You may not need to install it if there were proper slope in the horizontal drainpipe. Note 4 The flexible hose should not be installed upward position, it may cause water flow back to the indoor unit. 220-240V~ or EEV kit Indoor Unit 1 Indoor Unit 3 Indoor Unit 2 h ELCB : Essential Installation WARNING Power off before connecting any wires; Indoor PBA will be damaged while V1,V2,F3,F4 short each other. Indoor Unit 4 Indoor Unit 5 Indoor Unit 6 h Ceiling, wall-mounted indoor unit. Selecting compressed ring terminal 1~1.5m Air vent Silver solder 200mm or more 300mm or less Hanger 20mm or more Flexible hose Within 300~550mm Norminal dimensions for cable (mm2) Norminal dimensions for screw (mm) B D d1 E F L d2 t Standard dimension (mm) Allowance (mm) Standard dimension (mm) Allowance (mm) Standard dimension (mm) Allowance (mm) Min. Min. Max. Standard dimension (mm) Allowance (mm) Min. 1.5 4 6.6 ±0.2 3.4 +0.3 -0.2 1.7 ±0.2 4.1 6 16 4.3 +0.2 0 0.7 4 8 2.5 4 6.6 ±0.2 4.2 +0.3 -0.2 2.3 ±0.2 6 6 17.5 4.3 +0.2 0 0.8 4 8.5 4 4 9.5 ±0.2 5.6 +0.3 -0.2 3.4 ±0.2 6 5 20 4.3 +0.2 0 0.9 Horizontal drainpipe more than 1/100 slope Ceiling Centralized Drainage Without the drain pump 1. Install horizontal drainpipe with a slope of 1/100 or more and fix it by hanger space of 1.0~1.5m. 2. Install U-trap at the end of the drainpipe to prevent a nasty smell to reach the indoor unit. Specification of electronic wire Power supply MCCB ELB or ELCB Power cable Earth cable Communication cable Max : 242V Min : 198V XA XA, 30mmA 0.1 sec 2.5mm2 2.5mm2 0.75~1.5mm2 100mm or more . Decide the capacity of ELCB(or MCCB+ELB) by below formula. Horizontal drainpipe more than 1/100 slope Ceiling The capacity of ELCB(or MCCB+ELB) X[A] = 1.25 X 1.1 X .Ai With the drain pump 1. Install main air vent at the front of the farthest indoor unit from the main drain when installed indoor units are more than 3. 2. You may need to install individual air vent to prevent water flow back at the top of each indoor unit drainpipe. T X : The capacity of ELCB(or MCCB+ELB). T .Ai : Sum of Rating currents of each indoor unit. T Refer to each installation manual about the rating current of indoor unit. . Decide the power cable specification and maximum length within 10% power drop among indoor units. 1~1.5m Main air vent Hanger Individual air vent . ( Coef.35.6.Lk.ik ) < 10% of input voltage[V] 1000.Ak 550mm or less n k=1 T Coef: 1.55 T Lk: Distance among each indoor unit[m], Ak: Power cable specification[mm2], ik: Running current of each unit[A] Main drainpipe Centralized horizontal drainpipe (more than 1/100 slope) Indoor Unit Setting Additional Functions 1. Before installing the indoor unit, assign ...
Otros modelos de este manual:Los acondicionadores de aire - AVXDSH140EE (1.11 mb)
Los acondicionadores de aire - AVXDUH056EE (1.11 mb)
Los acondicionadores de aire - AVXDUH071EE (1.11 mb)
Los acondicionadores de aire - AVXDUH090EE (1.11 mb)