Resumen del manual


Visit us on the web at Additional rating information can be found at versatile system of air conditioning. It is designed to be custom- matched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-on coils are available for use with upflow, downflow, or horizontal furnaces and air handlers. WARRANTY 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES • QUALITY CONDENSER COILS -The coil is constructed of aluminum microchannel tubing and enhanced aluminum fins for increased efficiency and corrosion protection. • PROTECTED COMPRESSOR -The compressor is internally protected against high pressure, temperature, and externally by a factory installed high pressure switch. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. • DURABLE FINISH -The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight. • LOWER INSTALLED COST -Installation time and costs are reduced by easy power and control wiring connections. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. • TOP DISCHARGE -The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. • LOW OPERATING SOUND LEVEL -The upward air flow carries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. • LOW MAINTENANCE -Long life permanently lubricated motor-bearings need no annual servicing. • EASY SERVICE ACCESS -Fully exposed refrigerant connections, and a single panel covering the electrical controls make for easy servicing of the unit. • SECURED SERVICE VALVES -Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. • U.L. and C.U.L. listed -approved for outdoor application. • Agency Listed -U.L. and C.U.L. listed - approved for outdoor application. The unit is certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 415571-UTG-C-0309 Physical and Electrical Data MODEL TCGD30 S43S1 TCGD36 S43S1 TCGD42 S43S1 TCGD48 S43S1 TCGD60 S43S1 TCGD30 S44S1 TCGD36 S44S1 TCGD42 S44S1 TCGD48 S44S1 TCGD60 S44S1 Unit Supply Voltage 208-230V, 3.. 60Hz 460V, 3.. 60Hz Normal Voltage Range 1 187 to 252 432 to 532 Minimum Circuit Ampacity 11.4 12.3 16.3 15.5 23.9 9.4 7.1 8.0 7.9 13.5 Max. Overcurrent Device Amps 2 15 20 25 25 40 15 15 15 15 20 Min. Overcurrent Device Amps 3 15 15 20 20 25 15 15 15 15 15 Compressor Type Recip Recip Recip Recip Scroll Recip Recip Recip Recip Scroll Compressor Amps Rated Load 8.1 8.6 11.8 11.2 17.9 6.6 4.5 5.2 5.1 9.6 Locked Rotor 63 68 88 88 120 30 34 44 44 70 Crankcase Heater No No No No No No No No No No Fan Motor Amps Rated Load 1.2 1.5 1.5 1.5 1.5 1.2 1.5 1.5 1.5 1.5 Fan Diameter Inches 17.5 22 22 22 22 17.5 22 22 22 22 Fan Motor Rated HP 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Nominal RPM 1100 850 850 850 850 1100 850 850 850 850 Nominal CFM 2050 3200 2950 2950 3600 2050 3200 2950 2950 3600 Coil Face Area Sq. Ft. 9.6 13.07 14.16 14.16 18.68 9.6 13.07 14.16 14.16 18.68 Rows Deep 1 1 1 1 1 1 1 1 1 1 Fin / Inches 23 23 23 23 23 23 23 23 23 23 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 7/8 7/8 7/8 3/4 3/4 7/8 7/8 7/8 Unit Charge (Lbs. - Oz.) 4 3 - 14 4 - 9 4 - 5 4 - 9 5 - 6 3 - 14 4 - 9 4 - 5 4 - 9 5 - 6 Charge Per Foot, Oz. 0.62 0.62 0.67 0.67 0.67 0.62 0.62 0.67 0.67 0.67 Operating Weight Lbs. 131 145 173 173 195 131 145 173 173 195 1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by th...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría