Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Freecom Technologies, modelo RCS-M2000T

Fabricar: Freecom Technologies
Tamaño del archivo: 94.47 kb
Nombre del archivo: a446e265-f491-451f-bbe5-4b62c52172a6.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


0A9471 (Revised 11/97) TABLE OF CONTENTS Owner's Record ............................................................................................................2 Features ........................................................................................................................3 Accessories ..................................................................................................................3 Important Safety Information ........................................................................................4-5 Product Parts ................................................................................................................6 The Control Panel ........................................................................................................7 Specifications................................................................................................................8 Before Using ................................................................................................................8 Operation ......................................................................................................................9 Accessory Installation ..................................................................................................10 Exhaust Duct Kit......................................................................................................10 Window Panel Kit ....................................................................................................11 Maintenance and Cleaning ..........................................................................................12 Emptying Condensate Water Tank ..........................................................................12 Cleaning Air Filter....................................................................................................13 Cleaning Cabinet Exterior ......................................................................................14 Storage..........................................................................................................................15 Troubleshooting ............................................................................................................16 WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE. DO NOT OPEN CABINET. DANGEROUS HIGH VOLTAGE IS PRESENT. REFER SERVICING ONLY TO QUALIFIED PERSONNEL. Your air conditioner contains a refrigerant which is converted from a gas to a liquid by a highly efficient compressor. It has been designed to operate in a vertical position only. Should it be necessary to lay the unit on its side, place it in its upright position for a minimum of two hours before restarting or operating the unit. This time period permits the liquids, gases and oils contained within the sealed systems to return to their proper positions. OWNER’S RECORD Enter product information here for future use: Date of Purchase Dealer Model No. Serial No. FEATURES Thank you for purchasing the FREECOM RCS-M2000 Portable Air Conditioner. The RCS-M2000 series Portable Air Conditioner is designed with many state-of-the art features: • Quiet, durable caster wheels allow for easy movement and instant spot cooling in any room. • Convenient, electronic operation panel enables one-touch control of all functions. • Provides clean, fresh, air conditioned, dehumidified air. • Automatic, oscillating louvers provides air distribution over a wide area . • Low-noise, rotary compressor cools from air-to-air—no water required. • Attractive design and easy-to-clean exterior cabinet. ACCESSORIES The FREECOM RCS-M2000 Portable Air Conditioner offers a wide range of accessories to customize your installation. • Exhaust Duct Kit (provided) increases cooling efficiency by directing warm air exhaust from room to be cooled. • Window Panel Vent Kit (two sizes available; special order only) prevents outside air from entering the room when used with the Exhaust Ducting Kit. • Sliding Door Vent Kit (special order only) allows exhaust air to be directed out a sliding door while preventing outside air from entering room when used with the Exhaust Ducting Kit. • Window Snap Lock Kit (special order only) aids in maintaining proper window opening when using Window Panel Vent Kit. • Ceiling Panel Kit (special order only) replaces a standard 2-foot dropped ceiling panel for warm air exhaust. • Through-the-Wall Kit (special order only) can be installed into the wall for warm air exhaust. • Tank Microswitch Bypass Plate (special order only) can be installed to bypass the condensate water tank. This accessory can be used to drain condensate water to a field-installed drain pipe. • Sub Water Tank Attachment (special order only) allows for added condensate water holding capacity when it is attached to the main water tank. TRES IMPORTANT Pour eviter les risques d'incendie ou de choc electrique, n'exposez pas l'appareil a l...

Otros modelos de este manual:
Los acondicionadores de aire - RCS-M2000U (94.47 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría