Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Goodman Mfg, modelo AVPTC AVPTC313714

Fabricar: Goodman Mfg
Tamaño del archivo: 179.18 kb
Nombre del archivo: TM-AVPTC.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


POWER SUPPLY IS 220-240 V, 60 HZ, 1 PHASE Installation Before installing this appliance insure that it is properly sized and adequate power is available. This appliance can be installed in the vertical position without modification. The horizontal left and downflow positions require product modification and instructions for these field conversions can be found in the AVPTC installation instruction manual. This product is designed for zero inches (0 inches) clearance; however, adequate access for service or replacement must be considered without removing permanent structure. This unit can be installed on a platform when deemed necessary. In an attic installation a secondary drain pan must be provided by the installer and placed under the entire unit with a separate drain line properly sloped and terminated in an area visible to the owner. This secondary drain pan is required in the event that there is a leak or main drain blockage. Closed cell insulation should be applied to the drain lines in unconditioned spaces where sweating may occur. Appliances installed in garages, warehouses or other areas where they may be subjected to mechanical damage must be suitably guarded against such damage by installing behind protective barriers, being elevated or located out of the normal path of vehicles. When installed on a base, the base must also be protected by similar means. Heating and cooling equipment located in garages, which may generate a glow, spark or flame capable of igniting flammable vapors, must be installed with the ignition source at least 18"[46cm] above the floor level. When more than one appliance is installed in a building it shall be permanently identified as to the area or space serviced by the equipment. WARNING If this appliance is installed in an enclosed area such as a garage or utility room with any carbon monoxide (CO) producing appliance (i.e. automobile, furnace, water-heaters, etc.), ensure the area is properly ventilated. PRODUCT DESIGN When this product is installed in the downflow installation in an unconditioned space, remove the horizontal drain pan and install the following insulation kit AVPTC Model Insulation Kit 1830 DPI36-42/20 3137 4260 DPI48-61/-20 This kit is used to prevent sweating on the vertical drain pan. To prevent the horizontal drain pan from sweating in high humidity applications, it is recommended that a DPIH insulation accessory kit be used. NOTE: The DPIH insulation kit is not supplied with this product and must be purchased separately. See following chart for the correct DPIH kit. AVPTC Model Insulation Kit 1830 DPIH36-42 3137 4260 DPIH48-61 *AVPTC is a multi-position, variable-speed air handler and is used with R-410A. The unit's blower design includes a variable- speed ECM motor and is compatible with heat pumps and variable-capacity cooling applications. (See note below.) *NOTE: Factory-sealed to achieve a 2% or less leakage rate at 1.0" water gauge external duct static pressure. Complies with the Factory-sealed Air Handling Credit as listed in the 2001 Florida Building Code, Chapter 13, Section 610.2.A.2.1. PRODUCT DIMENSIONS AVPTC F G H INLET (FRONT VIEW) D C SUCTION LINE LIQUID LINE INLET TUBE B E I INLET (RIGHT SIDE VIEW) A Model A B C D E F G H I J AVPTC183014 46 3/4" 22" 17 1/2" 19 1/2" 10' 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" AVPTC313714 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" AVPTC426014 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" PRODUCT SPECIFICATIONS AVPTC AVPTC183016* AVPTC313716* AVPTC426016* Blower Wheel Diameter 9 1/2" 10 5/8" 10 5/8" Width 8" 10 5/8" 10 5/8" Lineset Connection Size Coil Drain Connection FPT 3/4" 3/4" 3/4" Liquid 3/8" 3/8" 3/8" Suction 3/4" 7/8" 7/8" Electrical Data Voltage 208/240 208/240 208/240 Min. Circuit Ampacity 4.9/4.9 6.5/6.5 8.6/8.6 Max. Overcurrent Device (amps) 15/15 15/15 15/15 Minimum VAC 197 197 197 Maximum VAC 253 253 253 Blower Motor FLA 3.90 5.20 6.90 HP 1/2 3/4 1 Ship Weight (lbs) 127 178 197 BLOWER PERFORMANCE DATA C -------7.5min/82%60 sec/100% Profiles Pre-Run Short-Run OFF Delay To set Comfort Mode: B-------30sec/50%60sec/100% Speed Selection Dip Switches 0140A00048 REV A A OFF OFF OFF OFF OFF OFF D 30 sec/50%7.5min/82%30sec/50% To set airflow: TAP 1 2 3 4 5 6 B ON OFF ON OFF ON OFF A ---------------60 sec/100% Select desired Comfort Mode profile (see profiles above). Set switches 5 and 6 to the approriate ON / OFF positions. (1) Select model and desiredhighstagecooling airflow.Determinethe cooresponding tap( A, B,C,or D ).Set dip switches1and2to the appropriateON / OFFpositions.(2) Select modeland installed electricheater size. Set switches 9, 10, and 11 to the appropriate ON/OFF positions. (3) Select the airflow adjustment factor tap A and D are 0%; Tap B is +10%; Tap C -10%. Set dip switches 3 and 4 to the appropriate ON / OFF positions. C OFF ON OFF ON OFF ON D ON ON ON ON ON ON Cool Adjust Profile Selection Selection Selection Switches Switches S...

Otros modelos de este manual:
Los acondicionadores de aire - AVPTC AVPTC183014 (179.18 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría