Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Bryant, modelo 579D

Fabricar: Bryant
Tamaño del archivo: 1.46 mb
Nombre del archivo: pds585e.90.4d.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Both models present a low profile and do not distract from the architecture of the building. MODEL 585E is designed for horizontal side-by-side duct connections and can be installed at ground level or on a roof. The 585E is ideal for the replacement market. MODEL 579D has the supply- and return-air openings on the bottom of the unit. The 579D is designed for rooftop installation and mounts on a factory-supplied, roof-mounting curb. The ductwork connects to the curb so that the air ducts and curb can be installed before unit arrival. FEATURES FACTORY-ASSEMBLED PACKAGE is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, prepiped, and precharged for minimum installation time and expense. TWO RUGGED, HIGH-EFFICIENCY COMPRESSORS provide two-stage cooling to conserve energy by shutting down one compressor during light cooling loads. These compressors are electrically and mechanically independent; therefore, cooling is still available even if one stage fails. LOW-PRESSURE PROTECTION is standard. TWO-STAGE HEATING AND TWO-STAGE COOLING reduces equipment cycling and gives better control of the conditioned space temperature and humidity. INTERMITTENT SPARK IGNITION that lights pilot only on a “call for heat” by the indoor thermostat. An LP (propane) conversion kit is available for both models. HIGH-EFFICIENCY, FOUR-PASS HEAT EXCHANGER-The four-pass tubular heat exchanger design provides maximum heat transfer to the heated area. POSITIVE-PRESSURE COMBUSTION AND MECHANICAL FLUE GAS VENTING are unaffected by adverse wind conditions. CRANKCASE HEATERS AND FILTERrDRIERS are standard on both models. WEATHERIZED CABINETS are constructed of heavy-duty, phosphated, zinc-coated steel and finished with corrosion-resistant, modified alkyd, fade-resistant, baked Malibu Beige enamel. Interior surfaces of the evaporator/heat exchanger compartment are insulated to help keep the conditioned air from being affected by the outdoor ambient temperature. VERTICAL CONDENSER AIR DISCHARGE prevents recirculation of hot condenser air and reduces operating noise level. COMPRESSOR ISOLATION MOUNTING eliminates vibration (noise) transmission to building structure. CORROSION-RESISTANT HEAT EXCHANGERS AND BURNERS for longer life. FURNACE SAFETY CONTROLS shut off gas in event of pilot outage, combustion-air failure, overheating of heat exchangers, or flame rollout. PROTECTION AS REQUIRED BY N.E.C. for fan motors. COMPROTEC®—standard on both models, prevents compressor rapid-cycling. RTU-29 Form No. PDS 585E.90.4B ■NOJ ModeX^85EJ)IMENSIONAL DRAWING (Inches) OUTDOOR COIL BURNER COMPARTMENT ACCESS PANEL 1-gOD x -^-ID DRAIN HOSE RIGGING HOLES FORK TRUCK SLOTS Front View ■jfDIA FIELD 0 CONTROL WIRING SPACE REQUIRED FOR I SERVICE AND AIRFLOW MODEL 585E TYPICAL APPLICATION A83047 RTU-30 MODEL 579D DIMENSIONAL DRAWING (Inches) OUTDOOR COIL BURNER -+COMPARTMENT ACCESS PANEL (14) lyDIA RIGGING HOLES FORK TRUCK SLOTS • OUTDOOR AIR ■ CONDENSER AIRFLOW i=> EVAPORATOR AIRFLOW ^ SPACE REQUIRED FOR SERVICE AND AIRFLOW Front View A82233 5-DIA FIELD ’CONTROL WIRING UNIT OPERATING AND CORNER WEIGHTS Operating Weight Corner Weights A B c D 1180* 367 244 228 341 *Add 60 pounds to unit if equipped with modulating economizer REAR FRONT A83000 RTU-31 SPECIFICATIONS I MODEL I 585EP09014é I 585EED90146 I 579DP090146 | 579DE09Ô146 I SERIES | "C C C C RATINGS & PERFORMANCE Cooling Total Capacity (Btuh)* 92,000 92,000 Capacity Reduction 50% 50% Rated Airflow (Ft3/Min)* 3000 3000 Rated ESP (In. wc)* 0.25 0.25 EER 8.2 8.2 ARI Noise Ratingt 9.0 9.0 Heating 1 st-Stage Input (Btuh) 86,000 86,000 1st-Stage Output (Btuh) 63,600 63,600 1st- & 2nd-Stage Input (Btuh) 146,000 146,000 1st- & 2nd-Stage Output (Btuh) 116,800 116,800 Temperature Rise Range (°F) 20-50 20-50 Thermal Efficiency (%) 80 80 Certified ESP (In. wc) 1.1 1.1 ELECTRICAL Unit Volts—Phase (60 Hz) 208/230-3 460-3 208/230-3 460-3 Operating Voltage Range 187-253 414-506 187-253 414-506 Unit Full Load Amps 42.7 20.7 42.7 20.7 Min Ampacity for Wire Sizing 48 23 48 23 Min Wire Size (75°C Copper)! 6 10 6 10 Max Wire Length (Ft)t 140 255 140 255 Max Fuse Size (Amps) 60 25 60 25 Control Transformer, 24-V (VA) 75 75 75 75 COMPRESSOR, REFRIGERANT, & CONTROLS Compressor No. 1 (Type-RPM) Hermetic—3500 Hermetic—3500 Hermetic-3500 Hermetic-3500 Rated Load Amps 15.2 7.2 15.2 7.2 Locked Rotor Amps 80 35 80 35 Compressor No. 2 (Type-RPM) Hermetic—3500 Hermetic—3500 Hermetic—3500 Hermetic-3500 Rated Load Amps 15.2 7.2 15.2 7.2 Locked Rotor Amps 80 35 80 35 Compressor Protection Internal Linebreak Internal Linebreak Low-Pressure Switch (PSIG) Cutout 27, Reset 67 Cutout 27, Reset 67 Low-Ambient Operation (°F) 45 45 Refrigerant Charge Compressor No. 1 Circuit 6 lbs 3 oz 6 lbs 3 oz Compressor No. 2 Circuit 6 lbs 3 oz 6 lbs 3 oz INDOOR COIL Rows & Fi...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría