Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Bryant, modelo 165A

Fabricar: Bryant
Tamaño del archivo: 891.95 kb
Nombre del archivo: pds165a-04.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The 165A has been designed utilizing Bryant’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. As an Energy Star ® Partner, Bryant Heating & Cooling has determined that this product meets the Energy Star® guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Star® guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (for the most up-to-date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency • 13.5 - 16.5 SEER/11.7-13.5 EER Aesthetic Design • Baked -on powder paint • Steel louver coil guard • Color matched cabinet screws Extra Quiet Operation • AeroQuiet II ™ for sound as low as 66 dBA — Quiet mount split post compressor grommets — Exclusive Silencer top design — Forward-swept condenser fan blade — Compressor sound hood — Laminated compressor mounting plate Reliability, Quality and Toughness • Scroll compressor • Field-installed 16 cu. in. filter drier • 8-pole PSC ball-bearing condenser fan motor • Back -seating service valves • High -pressure switch • Low-pressure switch • Internal pressure relief valve • Internal thermal overload Controls and Diagnostics • Standard thermostat control with 3-wire or 2-wire 24v connection to outdoor unit. (2-wire cpability starts with serial number 3006) • Utility Interface Connection • Up to 14 point diagnostic capability Applications • Longline - up to 250 ft. total equivalent length • Low-ambient operation (down to 0°F) with complete Infinity™ System and crankcase heater • Low-ambient operation (down to 0°F) with standard thermostat and additional accessories (see Accessory Usage Guideline in this document). 165A MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 6 5 A N A 0 3 6 0 0 0 A Product Tier SEER Major Se- Voltage Variations Cooling Capacity Open Open Open Minor Family ries Series II 6= 5 = 15 A=Puron N= A = 0=Not 0= 0= A = Preferred SEER 208-230-1 Standard Defined Not Not Original Series Nominal Defined Defined Series Puron the environmentally sound refrigerant ISO 9001:2000 ENERGYSTAR PARTNER This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging andair flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES Feature 018—B 024—B 030-B 036-B 042 — B 048 — B 060-B Puron® Refrigerant X X X X X X X Up to 16.5 SEER X X X X X X X Standard thermostat w/ 3- or 2-wire 24v connections to outdoor unit. X X X X X X X Scroll Compressor X X X X X X X Field Installed 16 cu. in. Filter Drier X X X X X X X Back Seating Service Valves X X X X X X X High-pressure Switch X X X X X X X Low-pressure Switch X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low-ambient capability to 0° F w/Complete System X X X X X X X Up to 14 Diagnostic Check-Points X X X X X X X Utility Interface Connections X X X X X X X 2 PHYSICAL DATA UNIT SIZE SERIES 018-B 024-B 030-B 036-B 042-B 048-B 060-B Operating Weight lb (kg) 186 (89.4) 198 (89.8) 258 (117.0) 259 (117.5) 320 (145.1) 326 (147.9) 330 (149.7) Shipping Weight lb (kg) 228 (103.4) 229 (103.9) 298 (135.2) 299 (135.6) 355 (161.0) 361 (163.7) 365 (165.6) Compressor Type Scroll REFRIGERANT Puron® (R-410A) Control TXV (Puron® Hard Shutoff) Charge lb (kg) 5.28 (2.39) 5.66 (2.57) 0. 7 -si 8 ) 0. 0 CO 5 ) 0) .9 (4. o .8 0. 11.40 (5.17) 13.17 (5.97) COND FAN Forward Swept, Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 2140 2140 2595 3265 3265 3673 3673 Motor HP 1/12 1/12 1/10 1/6 1/6 1/4 1/4 Motor RPM 800 800 800 800 800 800 800 COND COIL Face Area (Sq ft) 16.08 16.08 18.30 18.30 24.40 24.40 24.40 Fins per In. 25 25 20 20 20 20 20 Rows 1 1 2 2 2 2 2 Circuits 4 4 6 6 8 8 8 VALVE CONNECT. (In. ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES (In. OD) Rated Vapor* 5/8 5/8 3/4 3/4 7/8 7/8 1-1/8 Liquid 3/8 *Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. NOTE: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría