The 113A has been designed utilizing Bryant’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. As an Energy Starr Partner, Bryant Heating and Cooling has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (for the most up- --to- --date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 13 - --14.5 SEER/10.55 - --12 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 76 dBA S Sound level as low as 74 dBA with accessory sound blanket Comfort S System supports Thermidistatt or standard thermostat controls Reliability S Puronr refrigerant - --environmentally sound, won’t deplete the ozone layer and low lifetime service cost. S Scroll compressor S Internal pressure relief valve S Internal thermal overload S Filter drier S Balanced refrigeration system for maximum reliability Durability DuraGuardt protection package: S Solid, durable sheet metal construction S Dense wire coil guard S Baked- --on, complete outer coverage, powder paint Applications S Long- --line - --up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) S Low ambient (down to - --20_F/- --28.9_C) with accessory kit Warranty S 5 year limited compressor warranty S 5 year limited parts warranty MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 1 3 A N A 0 3 6 0 0 0 0 Product Family Tier SEER Major Series Voltage Variations Cooling Capacity Open Open Open Series 113A 1= 0=Not N= 208---230---1 0=Not 0=Not 1=AC Legacy 3=13 SEER A=Puron A= Standard Defined or 208/230---1 Defined Defined RNC the environmentally sound refrigerant REGISTERED ISO 9001:2000 This product has been designed and manufacturedto meet Energy Star® criteria for energy efficiencywhen matched with appropriate coil components. However, proper refrigerant charge and proper airflow are critical to achieve rated capacity andefficiency. Installation of this product shouldfollow all manufacturing refrigerant charging andair flow instructions. Failure to confirm propercharge and air flow may reduce energy efficiencyand shorten equipment life. STANDARD FEATURES 048 060 XX 14.5 13.5 XX XX XX XX XX XX XX Low Ambient capability with Kit X X X X X X X X= Standard Feature018024030036042PuronRefrigerantXXXXXMaximumSEER14.514.514.514.014.0ScrollCompressorXXXXXDenseWireCoilGuardXXXXXFieldInstalledFilterDrierXXXXXFrontSeatingServiceValvesXXXXXInternalPressureReliefValveXXXXXInternalThermalOverloadXXXXXLongLinecapabilityXXXXX 2 35678911112223300111112233455111112200011113345678111222300111113567891111222330011111223345511111220001111334567811122230011111 PHYSICAL DATA * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered ”Long m) when outdoor unit is above indoor unit, and up to 80 ft. (24.38 line” when the total equivalent tubing length exceeds 80 ft. (24.38 m) when the outdoor unit is below the indoor unit. Refer to m) or when there is more than 20 ft. (6.09 m) vertical separation Accessory Usage Guideline below for required accessories. See between indoor and outdoor units. These applications require Longline Application Guideline for required piping and system additional accessories and system modifications for reliable system modifications. Also, refer to the table below for the vapor tube operation. The maximum allowable total equivalent length is up to diameters based on the total length to minimize the cooling 250 ft. (76.2 m). The maximum vertical separation 200 ft. (60.96 capacity loss. Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) Vapor Line Standard 26---50(7.9---15.2) 51---80(15.5---24.4) 1/215/803/405/803/407/805/813/407/805/814568910123/4012233447/8001111223/4022344567/80111222311/8000000003/4023455677/80112223311/8000000113/414567910117/801223445511/8000111111Diameters Long Line Application Requires Accessories Application (In. OD) 81- ---100 101- ---125 126- ---150 151- ---175 176- ---200 201- ---225 226- ---250 (24.7- ---30.5) (30.8- ---38.1) (38.4- ---45.7) (46.0- ---53.3) (53.6- ---61.0) (61.3- ---68.6) (68.9- ---76.2) 2 1 0 1 0 0 2 0 0 2 1 0 1 0 0 1 3/8 0 0 60000 2 1Stage 3/8 Puron AC 113A 018---D024---D030---E036---E042---COperatingWeightlb(kg)107(48.5) 110(49.9) 111(...