Iniciar sesión:
Votos - 0, Puntuación media: 4 ( )

Manual de usuario York, modelo AFFINITY R-410A

Fabricar: York
Tamaño del archivo: 2.49 mb
Nombre del archivo: 559d5b6c-29a3-41a7-bc11-fcd6211440d1.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Only utility and duct connections are required at the point of installation. Field-installed electric heater accessories are available to provide electric heat, if required. ISO 9001 Certified Quality Management System FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 333495-YTG-C-0908 Table of Contents Description ............................................................................................ 1 Table of Contents.......................................................................................2 Component Location ....................................................................................2 Nomenclature..........................................................................................3 Heat Pump.............................................................................................3 Features and Benefits....................................................................................3 Guide Specifications.....................................................................................5 Physical Data...........................................................................................7 Capacity Performance.................................................................................. 10 Airflow Performance....................................................................................30 Sound Performance .................................................................................... 37 Electrical Data.........................................................................................38 Weights and Dimensions................................................................................49 Component Location Heat Pump 2 Johnson Controls Unitary Products 333495-YTG-C-0908 Nomenclature Heat Pump B 1 HZ 024 A Об Product Category B = Single Package Heat Pumps (Air Cooled) Product Generation 1 = New or Current Design 2 = 2nd Generation Voltage Code 06 = 208/230-1-60 25 = 208/230-3-60 46 = 460-3-60 Factory Installed Electric Heat A = No Electric Heat Installed Product Identifier Nominal Cooling Capacity (MBH) HZ = R-410A 13 SEER HX = R-410A 15 SEER 024 = 24,000 BTUH 042 = 42,000 BTUH 030 = 30,000 BTUH 048 = 48,000 BTUH 036 = 36,000 BTUH 060 = 60,000 BTUH Features and Benefits Standard Features • Operating Efficiency - All heat pump units provide operating efficiencies of 13 to 15 SEER and 7.7 to 8.0 HSPF. All efficiencies exceed legislated minimum levels. • On Site Flexibility - All model sizes share a common, compact design cabinet in a single footprint. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof, plus, the installer can fit this unit between the wheel wells of full size pick-up truck. • All units are completely wired, charged with R-410A and tested prior to shipment. Unique test stations using a new state of the art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers at assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. • Equal size, side supply and return duct connections allows easy hook-up of ducts to match low crawl spaces without transition pieces. • Utility Connections Made Easy - Electric utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, you simply remove the two panels from the bottom of the unit and place them in the side supply/side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A non-corrosive, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate. Less collection of stagnate condensate will build-up. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPTF connection is rigidly mounted to assure proper fit and leak tight sea...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría