Type UB-3502A, UB-4002A, UB-4502A, UB-5002A Forced-Air Heater Figure 1 Figure 2 (Wall Mounted) (Ceiling Mounted) Specifications – Table A Model Volts and Phase kW Horizontal Air Discharge Wt. (Lbs.) UB-3502A 240V, 550V, 575V, 600V (3o) 480V (1o or 3o) 35 54’ 210 UB-4002A 480V (1o or 3o) 550V, 575V, 600V (3o) 40 54’ 210 UB-4502A 480V (1o or 3o) 550V, 575V, 600V (3o) 45 54’ 210 UB-5002A 480V, 550V, 575V, 600V (3o) 50 54’ 210 IMPORTANT WARNING: Hazard of Electric Shock. Disconnect WARNING: Users should install adequate back-up all power before installing heater. controls and safety devices with their electric heating equipment. Where the consequences of WARNING: This heater is not intended for use in failure may be severe, back-up controls are essen hazardous atmospheres where flammable vapors, tial. Although the safety of installation is the gases, liquids or other combustible atmospheres responsibility of the user, Chromalox will be glad to are present as defined in the National Electrical make equipment recommendations. Code. Failure to comply can result in explosion or fire. For these applications see PDS CXH-EP (PF305). © 2010 Chromalox, Inc. IMPORTANT Do not mount mercury type thermostat directly on unit. Vibration could cause heater to malfunction. The heater must be mounted at least 7’ above the floor to prevent accidental contact with the heating elements or fan blade which could cause injury. Keep at least 5’ clearance in front of the heater. Refer to Figures 1 and 2 for side, top, and back clearance requirements. The wall or ceiling mounting structure and the anchoring provision must be of sufficient strength to support the combined weight of the heater and mounting bracket. (Refer to Table A for weights of heater and bracket). Fan blade rotation must be checked. If airflow is not moving out through the louvers, interchange any two of the three customer power leads on three-phase units only. MOUNTING WARNING: Hazard of Electric Shock. Disconnect all power before installing heater. WARNING: These heaters are designed for wall or ceiling mounting only. Other modes of mounting voids factory warranty. 1. Height above floor A. In areas where ceiling height is more than 12 feet, recommended mounting height is approximately 10 feet to underside of heater. B. For ceiling heights of 12 feet or less, maximum mounting height is determined by use of ceiling mounting brackets offered with these heaters. Minimum spacing to ceiling is 14-1/4”. C. In either case the minimum mounting height is 7 feet from floor to bottom of heater. (See Figures 1 and 2.) 2. Spacing to adjacent walls A. Rear of case to back wall 11” minimum. B. Side of case to side wall 12” minimum. 3. If two or more units are operated in the same enclosed space, their discharges should be directed to aid in development of mass air movement for uniform heat dispersal. 4. Controlling thermostats to individual heaters should be mounted at shoulder height on inside walls or columns. WIRIN...

Otros modelos de este manual:
Los acondicionadores de aire - UB-3502A (667.63 kb)
Los acondicionadores de aire - UB-4502A (667.63 kb)
Los acondicionadores de aire - UB-5002A (667.63 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría