Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Minolta, modelo W121CA TSC2

Fabricar: Minolta
Tamaño del archivo: 2.09 mb
Nombre del archivo: LG_W182CM_ENG.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


OFF( ) : Stops the operation of air swing. THERMOSTAT Turn the thermostat control to the desired setting. The control position is a normal setting for average conditions. You can change this setting, if necessary, in accordance with your temperature preference. The thermostat automatically controls cooling or heating, but the fan runs continuously whenever the air conditioner is in operation. If the room is too warm, turn the thermostat control clockwise. If the room is too cool, turn the thermostat control counterclockwise. HEATER ( ) LAMP When the unit sets heating operation condition, the green lamp is lighted. When the frost settles on the heat exchanger of the outside, defrosting is made automatically and the green lamp is turned off. The unit may give a "hiss" and the fan motor stops for 1 to 10 minutes. This should not be regarded as a problem. After defrosting, the heating operation begins again. OPERATION OFF ( ) : Turns the air conditioner off. LOW FAN ( ) : Permits the low fan speed operation without cooling (heating). LOW COOL ( ) : Permits cooling with the low fan speed operation. HIGH COOL ( ) : Permits cooling with the high fan speed operation. LOW HEAT ( ) : Permits heating with the low fan speed operation. HIGH HEAT ( ) : Permits heating with the high fan speed operation. CAUTION : When the air conditioner has been performed its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again. o The controls will look like one of the following. CLOSE VENT OPEN Part A Part B Adjusting the Air Flow Direction Operating Instructions 11 ENGLISH Additional controls and important information. Ventilation Air Direction The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is drawn out. The direction of air can be controlled whenever you want to cool by adjusting the horizontal louver and the vertical louver. • HORIZONTAL AIR DIRECTION CONTROL To control horizontal direction of air flow, press the air flow direction control button and the air flow will be swept horizontally by the automatic air-swing system. If you want to stop the air flow from moving, press the button again at the desired position of the vane. • VERTICAL AIR-DIRECTION CONTROL The vertical air direction is adjusted by moving the horizontal louver. • Auto Swing Models The horizontal air direction is automatically controlled by setting the AUTO SWING switch to the ON position. :Before using the ventilation feature, position the lever, as shown. First, pull down part to horizontal line with part . NOTICE CABINET DRAIN PAN DRAIN HOSE SCREW DRAIN PIPE DRAIN HOSE DRAIN PIPE DRAIN ELBOW DRAIN HOSE Fig. 1 Fig. 2 12 How to Attach Drain Pan (Some Models) How to Connect a Drain Hose The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the air) is drained to the outside. In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed from the air may cause some water to collect. To remove this excess water you can install the drain pan as detailed below. 1. Take the drain pan which is located in the air discharge. 2. Remove the hole rubber from the base-pan (for some models). 3. Install the drain pan to the right corner of the cabinet with 4 (or 2) screws. 4. Connect the drain hose to the outlet located at the bottom of the drain pan.You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied). A drain hole is provided at the rear of the air conditioner unit. Select a drain method according to the following. 1. Remove the hole rubber from the base-pan. (for some models) 2. Connect a drain hose to the drain pipe as shown in Fig. 1. 3. Or connect a pipe elbow to the drain pipe, then connect a drain hose to the pipe elbow as shown in Fig. 2. Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through a dealer. Adjusting the Air Flow Direction Operating Instructions TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. 1 5 7 6 4 2 3 10 8 9 12 13 11 14 Screw Foam 1 5 7 6 3 4 2 15 10 8 9 12 13 11 14 14 Hardware Installation Hardware Installation Learning parts name prior to installation will help you understanding the installation procedure. Features 1. CABINET 2. HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) 3. VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) 4. AIR DISCHARGE 5. FRONT GRILLE 6. AIR INTAKE(INLET GRILLE) 7. AIR FILTER 8. CONTROL BOARD 9. POWER CORD 10. EVAPORATOR 11. CONDENSER 12. COMPRESSOR 13. BASE PAN 14. BRACE 15. REMOTE CONTROLLER Installation Hardware White styrofoam block 10~15 mm Over 50 cm HE...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría