Iniciar sesión:
Votos - 1, Puntuación media: 3 ( )

Manual de usuario Fujitronic, modelo FA-9000

Fabricar: Fujitronic
Tamaño del archivo: 1.12 mb
Nombre del archivo: efaa7ab7-5e3c-4bca-80b6-23716e558959.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Dry, Fan mode 10 9.3. How to set hmer 11 10, EMPTY THE RESIDUAL CONDENSATE WATER 12 11, MAINTENANCE 13 12, TROUBLESHOOTING —14 13, PRODUCT LIMITED WARRANTY 15 1 BEFORE INITIAL USE Read this entire instruciton manual before use. FOR YOUR OWN REFERENCE: Serial No.(underneath Product Label, on back of product):_ Date of Purchase: 2 QUICK STEP TO SET UP YOUR UNIT 3- INTRODUCTION This Portable Air Conditioner is designed for improving living and working comfort by adjusting the temperature and humidity in a room. Its mobility makes it easy to use in various rooms. To ensure the optimal efficiency of the air conditioner, we advise you to keep doors and windows closed, and to take into account the surface of the walls and windows exposed to the sun. In this case, in order to optimize the functioning of your air conditioner, we recommend partially closing window coverings. This unit has a three minutes compressor delay protection circuit. This unit is designed to be used in the room only, not for outdoor. Do not locate the unit where furniture or other object can obstruct the cooling airflow. Always keep the filter clean. Prevent any kink or blend in the middle of exhaust hose. The following advice and instructions should be followed closely: 1.Your unit must always be used in an upright position because it contains a cooling agent. 2. After unpacking, place the unit upright to allow the cooling agent to stabilize, and wait 3 hours before use. 4. SUGGESTION FOR YOUR USING 5. TECHNICAL SPECIFICATIONS Electrical Power Supply: Cooling Capacity: Rated Power Consumption: Rated Current: Refrigerant / Refrigerant charged Qty: Dehumidifying Capacity: Airflow Volume: Product Dimension: Product Net Weight: Product Gross Weight: Exhaust Hose Length: Programming Timer: 115V/60Hz 9000BTU/Hour 920W 8.2Amp R22/17.6 Oz 1.5 Pints/ Hour 200/153/129 Cubic Feet/Min 14 " (W) X13.8 " (D) x31 " (H) 54.6 lbs 65.3 lbs 63" (Max length) 24hours Test Condition: 95 F/83 F (Dry Bulb / Wet Bulb) 6. PARTS Please transport this product in an upright position only, and place the product on an even surface. Control Panel Wheel Hande E>n.nis1 Port UpOrain Port Down Oran Pert Front View Back View ACCESSORIES 7 SAFETY RULES The connection to the main clcctricity supply must comply with current safety regulations in your country for installation of home appliance. 1) Do not damage the power cord. 2) Never lay this unil down as it contains cooling agent. 3) Be sure that the air inlets and outlets are not blocked or covered up. 4) Never place anything on top ol the unit. 5) No not use this product outdoor. 6) Never connect ihe unit to a defective outlet. 7) This unit needs at least 10 Amp of electricity to start it’s compressor. Plug the unit into a property grounded dedicated 10 Amp or larger circuit. Check your breaker box to determine which circuit the outlet is on 8) Make sure that the unit is correctly connected before turning on the unit's power. 9) Do not unplug the air conditioner while it is working. 10) To avoid tripping Ihe circuit. DO NOT USE AN EXTENSION CORD FOR THIS UNIT. 11) Do not bend or crush the exhaust hose. 12) Do not allow children to play near the unit. 13) Do not place the power cord under a carpet. 14) Keep the area around the exhaust port /exhaust hose sufficiently clean and make sure that is not congested. 15) For any repairs, refer directly to our customer service department. Repairs carried out by unqualified people may cause damage or may even be dangerous and void the warranty. IT IS STRICTLY FORBIDDEN TO: • Place objects inside the air outlet or inlet grid. • Use this unit inside closets, cabinets and/or cramped spaces between furniture. • Repair, disassemble and/or modify the unit by yourself. • Block the air outlet and'or inlet grids. • Use this unit in proximity to inflammable and/or explosive substance. • Operate this unit without filter. Before cleaning this unit, make sure that it rs unplugged; do not wash the unit with water, gasoline or solvents of any kind. To avoid the risk of shock, the oroduct never be used in bathrooms, shower rooms, or in any other steamy or wet areas. Do not use the unit at slope because the unit is supported by four wheels. In the event of fire, use carbon dioxide(C02) extinguishers. Do not use water or powder extinguishers. This unit is provided with o Leakage Current Detection and Interruption circuit (LCDI) built into the plug of the power supply cord. This device provides protection to reduce the risk of fire due to arcing faults in the power-supply cord. Before use. follow the "Plug Testing Instructions" to ensure that the (LCDI) circuit is functioning property: PLUG TESTING INSTRUCTIONS: 1. Press Test Button. Unit should thp. 2. Press Reset Button firmly for use Reset Button may require pressure to engage DO NOT USE IF ABOVE TEST FAILS Do nol use Ihe TEST and RESET buttons as an on/off swi...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría