Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Hobart, modelo ML-134252

Fabricar: Hobart
Tamaño del archivo: 2.9 mb
Nombre del archivo: 597969e9-a821-a604-bd9a-e9e6d3277e44.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Rotate to Vertical. Slide Fence Up. Model 2912B Fig. 1 Tighten Thumbscrew. ELECTRICAL WARNING: THIS MACHINE IS PROVIDED WITH A THREE-PRONG GROUNDING PLUG. THE OUTLET TO WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. CLEAN BEFORE USING Thoroughly clean and sanitize the slicer after installation and before use. Refer to CLEANING, pages 6 –7. – 3 – OPERATION SAFETY SAFETY DEVICES INCORPORATED IN THIS SLICER MUST BE IN THEIR CORRECT OPERATING POSITIONS ANY TIME THE SLICER IS IN USE. The Top Knife Cover (Fig. 2) must be in position and secured with the Latch Knob (Fig. 2). The Ring Guard is not removable. The Deflector (Fig. 1), mounted below the slicer knife, can be removed for cleaning. The Meat Grip (Fig. 2) must be used when slicing short ends to keep your hand(s) away from the knife. When the slicer is not running, the Index Knob (Fig. 2) must be turned below zero (fully clockwise). The Gauge Plate will then cover the knife edge. Always UNPLUG the Power Cord before cleaning or moving the slicer. Model 2912B Fig. 2 – 4 – WARNING: ROTATING KNIFE. USE FEED GRIP. UNPLUG MACHINE POWER CORD BEFORE CLEANING, SERVICING, OR REMOVING PARTS. REPLACE PARTS BEFORE USE. SLICING — MODEL 2912B Loading the Product With the Gauge Plate fully closed and the Automatic/Manual Lever (Fig. 2) in the Manual position (down), pull the carriage all the way toward the operator end of the machine (Home position). With the Meat Grip out of the way, place the product to be sliced on the Carriage Tray. To adjust the Fence: Loosen the thumbscrew (Fig. 1); slide the Fence so it is close to the product but not pushing against it; retighten the thumbscrew. Set the Meat Grip against the product. The Meat Grip should be used when slicing. If using the optional food chute, the Meat Grip is not needed. It may be stored out of the way by sliding it to the top of its travel, rotating it under the Carriage Tray and allowing it to rest in the Retaining Clip (Fig. 2). Manual Slicing Adjust the Gauge Plate by turning the Index Knob (Fig. 2) to obtain the desired slice thickness. The numbers on the Index Knob do not indicate actual measurements but may be used for reference to duplicate slice thickness. Make sure the carriage is all the way toward the operator (Home position). Turn the slicer on by pulling the Start/Pause Knob (Fig. 2) until the slicer starts, and then release the knob. The Indicator Light is lit. If the Gauge Plate is not open before the Start/Pause Knob is pulled, the slicer will not continue to run when the Start/Pause Knob is released. Use the Carriage Handle (Fig. 2) to move the carriage back and forth to slice manually. To turn the slicer off, either push the Start/Pause Knob or close the Gauge Plate. Automatic Slicing Load the product as described above. Turn the Speed Selector Knob (Fig. 2) to the desired speed. The speed can be adjusted to any of the six speeds at any time. Adjust the Gauge Plate by turning the Index Knob to obtain the desired thickness. Make sure the carriage is all the way toward the operator (Home position). Rotate the Automatic/Manual Lever to the Automatic position. • To Start slicing — pull the Start/Pause Knob (Fig. 2) until the slicer starts, and then release it. The slicer knife motor and carriage drive unit will start, and the Indicator Light beside the Start/Pause Knob is lit. If the Gauge Plate is not open before the Start/Pause Knob is pulled, the slicer will not continue to run when the Start/Pause Knob is released. • To Pause — pull the Start/Pause Knob (Fig. 2) again, and then release it. The carriage will complete its cycle, returning to the Home position, and the slicer knife will stop. The Indicator Light goes off. • To Resume slicing — pull the Start/Pause Knob (Fig. 2) again, and then release it. • To Stop the slicer — push the Start/Pause Knob. To restart the slicer, it may be necessary to move the Automatic/Manual Lever to Manual (down), pull the carriage tray all the way toward the operator (Home position), place the Automatic/Manual Lever in Automatic (Up) and pull the Start/Pause Knob. To use the optional food chute, place the Meat Grip on the Retaining Clip, fit the hangers on the food chute around the meat grip slide rod (at front) and lower the food chute onto the Carriage Tray. – 5 – CLEANING This machine must be thoroughly cleaned and sanitized after each day’s operation or after being idle for an extended period of time. WARNING: THE SLICER KNIFE IS VERY SHARP. EXERCISE EXTREME CAUTION WHEN WORKING NEAR THE KNIFE. WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. Use a clean cloth soaked in a solution of mild detergent and warm water to wipe all surfaces of the machine. Rinse using a fresh cloth and clean water. Use only products formulated to be safe on stainless steel and aluminum. To clean the Carriage Tray, close the Gauge Plate and pull the Carri...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría