|
Resumen del manual
If pump runs but does not pump water: 1. Check for airlock. Be sure that outlet hose runs upward to the thru-hull connector, with no dips. (Figure 1) 2. Remove pump housing from base. Remove debris from chamber and impeller. Be sure impeller is firmly attached to shaft and is not cracked or broken. (Figure 2) If pump does not run: 1. Check fuse. Be sure electrical connections and fuse are waterproof and haven’t loosened. (Figure 3) To replace motor cartridge: 1. Hold pump housing, depress motor cartridge tab and twist cartridge counter-clockwise to remove (Figure 2). 2. Check motor cartridge fit: See specification chart for replacement motor cartridge number. Motor must match housing color: 500 Series = RED, 800 = BLUE, 1200 = GRAY. 3. To reinstall cartridge: Coat O-ring with vegetable oil (petroleum-based oils will cause deterioration). 4. Insert cartridge into housing. Twist clockwise until you hear tab snap up into slot. (Figure 2) ATTWOOD BILGE PUMPS LIMITED WARRANTY This Attwood Bilge Pump carries a three (3) year warranty. See product catalog or for details. ©2003 Attwood Corporation 1016 N. Monroe Street, Lowell, MI 49331-0260 ...
Otros modelos de este manual:Barcos - Tsunami 4613 (459.93 kb)
Barcos - Tsunami 4606 (459.93 kb)
Barcos - Tsunami 4608 (459.93 kb)
Barcos - Tsunami 4612 (459.93 kb)