Manual de usuario Omega Engineering, modelo DPG1100ADBL

Fabricar: Omega Engineering
Tamaño del archivo: 63.33 kb
Nombre del archivo: M3763.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Installation Precautions Tighten/remove with wrench on hex fitting only. Do not attempt to rotate gauge by turning housing. Use fittings appropriate for the pressure range of the gauge. Do not apply vacuum to gauges not designed for vacuum operation. NEVER insert objects into the gauge port or blow out with compressed air. Permanent damage not covered by warranty will result to the sensor. The DPG1100AD and DPG1100ADBL can be powered by any AC source of 8 to 24 VAC 50/60 Hz, or any DC source of 9 to 32 VDC. The gauges can be used with inexpensive unregulated low voltage AC or DC power supplies. The type and magnitude of the supply voltage have negligible effects on the gauge calibration as long as it is within the voltage ranges stated above. No polarity needs to be observed when connecting a DC supply. SPECIFICATIONS Ranges & Resolution –30.0 inHg vac to 15.0 psig –30.0 inHg vac to 100.0 psig 30.0 inHg vacuum, ±15.00 psig 3.00, 5.00, 15.00, 30.0, 100.0, 199.9 psig 300, 500, 1000 psig Absolute reference: 15.00, 100.0 psia Optional Units Most engineering units such as kPa, atm, bar, mbar, inHg, mmHg, inH2O, ftH2O, torr, kg/cm2, cmH2O, oz/in2 Display (type, size, update rate) 31/2 digit LCD, 1/2" digit height 3 readings per second nominal display update ADBL: Red LED display backlighting when gauge is on Accuracy (linearity, hysteresis, repeatability) ±0.25% of full scale or better, ±1 least significant digit NEVER connect the gauge wires directly to 115 VAC or permanent damage not covered by warranty will result. After the gauge is installed, route the wires safely and connect the AC adapter’s wires to the gauge cable. Lastly, plug the AC adapter into a 115 VAC outlet. The only important consideration is to ensure that the gauge supply voltage does not fall below 8 VAC RMS if AC power is used, or 9 VDC if DC power is used. Operation with less than these values may cause erratic or erroneous readings. If your application requires operation of multiple gauges from the same power supply, consult the factory for wiring recommendations. Operation When a supply voltage is applied, the gauge will be ready to use. If the gauge display is off, press the center button to turn the gauge on. If the gauge is in the power- on state and the power is disconnected, the gauge will turn on when power is reapplied. The gauge can be left on continuously or turned off when not in use. DPG1100ADBL model display backlighting will be on whenever gauge is on. Temperature Stability (relative to 77°F or 25°C) ±1% FS for offset & span, 32 to 158°F (0 to 70°C) typical ±2% FS for offset & span, 32 to 158°F (0 to 70°C) typical for 3 and 5 psi ranges Controls & Location Front button turns gauge on or off Front-accessible calibration potentiometers Non-interactive zero & span, ±10% range Power AD: Approximately 5 mA ADBL: Approximately 80 mA Operates on 8 to 24 VAC 50/60 Hz or 9 to 32 VDC Optional wall mount power supply is available to operate on 115VAC Weight (approximate) Gauge: 9 ounces, shipping weight: 1 pound Calibration Remove the calibration potentiometer covers on the front of the unit to access the zero and span controls. GAUGE reference units may be re-zeroed without affecting the span calibration. The gauge port must be open to the ambient with no pressure or vacuum applied. Adjust the Zero control until the gauge reads zero with the minus (–) sign occasionally flashing. Span calibration should only be attempted if the user has access to a pressure reference of known accuracy. The accuracy of the calibration equipment should be at least four times the gauge accuracy. Zero calibration must be done before span calibration. Record readings at three to five points over the range of gauge and adjust span control to minimize error and meet specifications. ABSOLUTE reference gauges require vacuum generation and atmospheric pressure measurement equipment for accurate calibration and thus are more difficult to calibrate in the field. Gauges may be returned to Omega Engineering for recalibration. N.I.S.T. traceability is available. 3 ft long, 2-conductor, 22 AWG shielded cable Optional Power Supply Kit DPG1000-PS The kit includes a UL and CSA listed 115 VAC (50/60 Hz) wall-mount power supply with U.S.-style 2-prong plug. Output is 12 VDC at 200 mA. The two-conductor wire is approximately 6 feet long with stripped wire ends. Use a pair of pliers to connect gauge and power supply wires using the included moisture-resistant connector. 2.0" 1/4" NPT 3.0" 3.5" 0.75" PSIG Span Zero OMEGA Engineering Inc. / Made in USA 0.75" Turn at hex fitting only! Housing NEMA 4X UV stabilized polycarbonate/ABS case, light gray color Clear polycarbonate window to protect display Gasketed rear cover, six captive stainless steel screws Pressure/Vacuum Connection and Material 1/4" NPT male, all wetted parts are 316 SS Overpressure & Burst 5000 psig for metric units using 3000 psig sensor 7500 psig for metric units using 5000 psig sensor All others 2x rated press...

Otros modelos de este manual:
equipamiento barco - DPG1100AD (63.33 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría