Manual de usuario Graham Field, modelo GRAFCO 14423-8

Fabricar: Graham Field
Tamaño del archivo: 370.3 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


s NOTICE: Ensure that relative humidity at the Pocket Doppler's location during storage does not exceed 93%. s NOTICE: If the battery terminals become dirty, wipe them with a clean, dry cloth before using the Pocket Doppler. s NOTICE: Batteries have life cycles. If the battery use time shortens noticeably, the battery's life cycle is over. Replace the old battery with a new one of the same size and type. Use only batteries recommended by GF Health Products, Inc. s NOTICE: Remove a battery whose life cycle is over from the Pocket Doppler immediately. s NOTICE: Dispose of the old battery in accordance with local regulations. 1. Apply a liberal amount of gel on the site to be examined. 2. Place the probe so that the head is at least at 45. to the vessel to be examined. 3. Adjust the position of the probe to obtain the loudest audio signal. For best results, keep the probe as still as possible once the optimum position is located. 4. Adjust the audio volume as necessary. Info: Arteries emit high-pitched rhythmical pulsation sounds, while veins emit non- rhythmical pulsation sounds similar to rushing wind. TURNING OFF THE POCKET DOPPLER 1. When the session is finished, press the front panel POWER button to turn off the Pocket Doppler. 2. Use a clean, dry, non-abrasive cloth to gently wipe off the remaining gel from the probe. After thoroughly cleaning the probe, replace it in the Pocket Doppler probe frame. REPLACING THE BATTERY When the Pocket Doppler battery power is low, turn the power off and replace the battery. See Section 5, SETUP, for instructions on battery replacement. Cleaning the Pocket Doppler Probe s NOTICE: Do not allow liquid to enter the ultrasound system. s NOTICE: Do not pour liquids on the probe while cleaning. The Pocket Doppler probe’s acoustic surface is fragile and must be handled with care. 1. To prolong the life of the probe, after each use, gently wipe off the remaining gel from the probe with a clean, dry, non-abrasive cloth. 2. After thoroughly cleaning the probe, replace it in the Pocket Doppler probe frame. 3. If necessary, wipe the external surface of probe with 70% ethanol or isopropranol alcohol. 4. Allow to air dry. s NOTICE: Do not allow any liquid or cleaning solution to remain on the surface of the probe after cleaning. DISINFECTION Disinfecting the Pocket Doppler Probe s NOTICE: Do not allow any liquid to enter the probe socket while disinfecting or immersing the probe. 1. Clean the exterior surface of the probe as recommended in the previous section. 2. To disinfect the probe, immerse the probe in a solution of Benzalkonium Bromide, 0.5% Chlorhexidine, 2% Glutaraldehyde, or 75% ethanol. 3. Wipe the probe with a clean, dry, non-abrasive cloth to remove any remaining moisture. s NOTICE: Do not allow any liquid or cleaning solution to remain on the surface of the probe after cleaning. 9 LIMITED WARRANTY GF Health Products Inc. warrants this product to be free from manufacturing defects in material and workmanship for its period of warranty that is in accordance with industry standards. This warranty is extended only to the original purchaser/consumer or dealer/non-consumer of this new product and to no other purchaser or transferee. GF Health Products, Inc. warrants the Grafco Pocket Doppler and its components to be free from defects in workmanship and materials for a period of one year. The Warranty period for the consumer commences on the first date a product is delivered to consumer by seller/dealer. If the product is rented or leased, the warranty period commences on the invoice date from GF Health Products, Inc. A copy of the invoice showing date of purchase must be provided when submitting warranty claims. When proof of purchase date is not provided, warranty coverage shall commence upon GF Health Products, Inc.’s invoice date to the dealer/purchaser. If within the warranty period, the product or component part is proven to GF Health Products, Inc.’s satisfaction to be defective, GF Health Products, Inc. shall provide, at its option, one of the following: (1) repair or replacement of any defective or nonconforming part or product or (2) a credit and/or refund of the original selling price. GF HEALTH PRODUCTS, INC.’S SOLE OBLIGATION AND YOUR EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR, REPLACEMENT, CREDIT AND/OR REFUND. This warranty does not include any labor charges incurred in replacement part(s) installation or any associated freight or shipping charges to the manufacturer. For warranty service, please contact the authorized dealer from whom you acquired your GF Health Products, Inc. product. Upon receiving notice of an alleged defect in a product, GF Health Products, Inc. will issue a return authorization. The defective product or part(s) must then be returned, at the purchaser’s cost, for warranty inspection using the serial number as identification (or, if the product is not serialized, lot number and date code) within thirty (30) days of ...

Otros modelos de este manual:
equipamiento barco - GRAFCO 14423-4 (370.3 kb)
equipamiento barco - GRAFCO 14423-2 (370.3 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría