Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario GE, modelo DMCD330EH

Fabricar: GE
Tamaño del archivo: 188.86 kb
Nombre del archivo: 5e31e84c-920b-477b-85d3-a3ea767d3528.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Capacity Coin-Operated Electric Dryer Dimensions and Installation Information (in inches) Electric Dryer Rating: 240V 5600W 24A 60Hz 208V 4400W 22A 60Hz Exhaust Option: Shipped with exhaust to the rear Electric Model Offers 4-way Venting: Left, right, bottom and rear. Maximum recommended exhaust duct length is 45 feet of 4" rigid ducting with two 90. elbows and 4" dampered wall cap. Circuit Requirements: An individual, properly-grounded branch circuit fused for 30-amp is required. Note: Dryer wall outlet must be located within 36" of service cord entry and acessible when dryer is mounted in position. Installation Information: For complete information, see installation instructions packed with your dryer. 362725-1/242 For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Listed by Underwriters Laboratories Specification Revised 6/09 370406 DMCD330EH GE® 7.0 Cu. Ft. Capacity Coin-Operated Electric Dryer For complete information, see installation instructions packed with your dryer. Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semirigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition duct. Please see installation instruction packed with your dryer for complete instructions when using flexible metal (foil type) ducting. Exhaust Length Calculation: 1.Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2.The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow. Dryers must be exhausted to the outside. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 3" front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • No other fuel-burning appliance shall be installed in the same closet with a gas dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers. Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces are: 0" both sides; 3" rear Dryer Exhausting Information: Use metal duct only, vertical and horizontal ducting. Best performance Maximum length of 4" dia. rigid metal duct Exhaust hood type B Number of A B 90° Domestic A4A2-1/2 4" 2-1/2" dryer models turns opening opening 0 90 ft. 60 ft. 1 60 ft. 45 ft. 7.0, 6.0 and 5.8 cu. ft. 2 45 ft. 35 ft. capacity models 3 35 ft. 25 ft. all electric dryers 4 25 ft. 15 ft. Listed by Underwriters Laboratories Specification Revised 6/09 370406 DMCD330EH GE® 7.0 Cu. Ft. Capacity Coin-Operated Electric Dryer Features and Benefits • Greenwald Coin System -Includes coin box, key, coin slide and related parts • Auto Dry -Uses thermostats to monitor air temperature and reduce fabric wear • Pushbutton Controls -Simplifies cycle selection • LED Readout - Provides accurate wash times, from fill t...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría