Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Toshiba, modelo MMU-AP0151MH

Fabricar: Toshiba
Tamaño del archivo: 3.52 mb
Nombre del archivo:
Idioma del manual:
Fotos y especificaciones  Toshiba  MMU-AP0151MH
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Use only tools designed to operate with R410A. To prevent the risk of charging with an incorrect refrigerant, the dimensions of the to those used for conventional refrigerant. Therefore only tools designed to operate For connecting pipes, use piping specifically designed for R410A. During installation, ensure pipes are clean and ensure contaminants do not enter in the pipes affected by impurities such as water, oxide scales, dirt, oil, etc. Do not use existing pipe work installation as this will cause problems due to pressure resistances and impurities within the pipe. CAUTION To Disconnect the Appliance from Main Power Supply. This appliance must be connected to the main power supply by means of a switch with a contact separation least 3 mm. WARNING • Ask an authorized dealer or qualified installation professional to install/maintain the air conditioner. Inappropriate installation may result in water leakage, electric shock or fire. • Turn off the main power supply switch or breaker before attempting any electrical work. Make sure all power switches are off. Failure to do so may cause an electric shock. • Connect all of the installation wiring correctly. If the installation wiring is incorrect electrical parts may be damaged. • During the transportation and installation of the air conditioning unit, ensure that gaseous matter other than the specified refrigerant does not enter into the refrigeration cycle. If a refrigerant becomes contaminated with foreign gases, the gas pressure within the refrigerant cycle will become abnormally high and may result in the fracture of pipe work and possible human injury. • Do not modify this unit by removing any of the safety guards or by overriding any of the safety interlock switches. • Exposure of the unit to water or other forms of moisture before installation may cause a short-circuit of the electrical parts. Do not store it in a wet basement or expose to rain or water. • After unpacking the unit, examine for possible damage. • Do not install in a place that might increase the vibration of the unit. • To avoid personal injury (with sharp edges), be careful when handling parts. • Perform installation work properly according to the Installation Manual. Inappropriate installation may result in water leakage, electric shock or fire. • When the air conditioner is installed in a small room, provide appropriate measures to ensure that in the event of a refrigerant leak the rooms does not exceed the critical level. 21 1 PRECAUTIONS • Install the air conditioner securely adequately. • Perform the specified installation work If the air conditioner is not installed appropriately, • If refrigerant gas has leaked during the installation If the leaked refrigerant gas comes in contact with • After the installation wor...

Otros modelos de este manual:
Receptores - MMU-AP0091MH (3.52 mb)
Receptores - MMU-AP0181MH (3.52 mb)
Receptores - MMU-AP0121MH (3.52 mb)
Receptores - MMU-AP0091MH (3.52 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría