synthetic material, the relative humidity should be at least 30%. Electrical fast 2 kV for power supply 2 kV for power supply Mains power quality should be that transient/burst lines lines of a typical commercial or hospital IEC 61000-4-4 1 kV for input/output lines 1 kV for input/output lines environment. Surge IEC 61000-4-5 1 kV line(s) to line(s) 2 kV line(s) to ear th 1 kV line(s) to line(s) 2 kV line(s) to ear th Mains power quality should be that of a typical commercial or hospital environment. interruptions and <5 % UT (>95 % dip in <5 % UT (>95 % dip in Mains power quality should be that voltage variations UT) for 0.5 cycle UT) for 0.5 cycle of a typical commercial or hospital on power supply input lines IEC 61000-4-11 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in environment. If the user of the monitor requires continued operation during power mains interruptions, it is recommended that the monitor be UT) for 25 cycles UT) for 25 cycles powered from an uninterruptible power supply or a batter y. <5 % UT (>95 % dip in <5 % UT (>95 % dip in UT) for 5 sec UT) for 5 sec Power frequency 3 A/m 3 A/m .......................................................................... (50/60 Hz) be at levels characteristic of a typical ........................G location in a typical commercial or IEC 61000-4-8 hospital environment. Note UT is the a.c. mains voltage prior to application of the test level. 3 1. Important Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING: ............................................................................................................................................................................................................................ the monitor should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment – guidance Por table and mobile RF communications equipment should be used no closer to any par t of the monitor, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance: d = 1.2 ..P d = 1.2 ..P 80 MHz to 800 MHz Conducted RF 3 Vrms 3 Vrms d = 1.2 ..P 800 MHz to 2.5 GHz IEC 61000-4-6 150 kHz to 80 MHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation Radiated RF 3 V/m 3 V/m distance in metres (m). IEC 61000-4-3 80 MHz to 2.5 GHz ................................................................................................................ by an electromagnetic site survey: a. Should be less than the compliance level in each frequency range. b. Interference may occur in the vicinity of equipment marked with the following symbol: Note .. At 80 MHz and 800 MHz, the higher frequency range applies. .. These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. .. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site sur vey should be considered. If the measured field strength in the location in which the monitor is used exceeds the applicable RF compliance level above, the monitor should be obser ved to verify normal operation. If abnormal performance is obser ved, additional measures may be necessar y, such as reorienting or relocating the monitor. .. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 4 1. Important Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM – for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING: The monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.The customer or the user of the monitor can help prevent electromagnetic interference by maintaining a minimum distance between por table and mobile RF communications equipment (transmitters) and the monitor as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter (W) Separation distance according to frequency of transmitter (Meter) 150 kHz to 80 MHz d = 1.2 ..P 80 MHz to 800 MHz d = 1.2 ..P 800 MHz to 2.5 GHz d = 2.3 ..P 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 Note .. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation appli...
Otros modelos de este manual:Monitores - C240P4QPYEW/27 (1.45 mb)