Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario LG, modelo T730SH

Fabricar: LG
Tamaño del archivo: 323.81 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


• 6500K: Slightly reddish white. • 9300K: Slightly bluish white. TEMP Select the screen temperature which you prefer among reddish or bluish or any color in between. RED GREEN BLUE Set your own color levels. To customize the screen status for a user's operating environment OSD Adjust Description VIDEO LEVEL LANGUAGE OSD TIME This item is used to select the monitor's input signal level. The normal level used for most PCs is 0.7V. If the screen becomes suddenly washed- out or blurred, please select 1.0V and try again. To choose the language in which the control names are displayed. OSD Menus are available in 12 languages: English, German, French, Spanish, Italian, Swedish, Finnish, Portuguese, Korean, Chinese, Russian and Polish. Set the OSD time, i.e. the length of time a menu will remain on-screen before it shuts off automatically. Adjust the time to 5, 10, 20, 30 or 60 seconds. A11 On Screen Display(OSD) Selection and Adjustment On Screen Display(OSD) Selection and Adjustment To improve the clarity and stability of the screen OSD Adjust Description H DEGAUSS RECALL RESET MOIRE CONVERGENCE* PURITY* * This function is available for designated models only. 8 To manually demagnetize the screen to avoid showing incorrect images or colors. You can use this function to reload the modified parameters for screen display operation, as specified by the user after purchase: Position, Size, Side Pincushion, Trapezoid (These recalled options may differ depending on the mode selected: Preset, User, or New). If you don’t want to recall the monitor to these modified settings, use the button to select CANCEL and then press the SELECT (or SET) button. Return to all factory default settings If you don’t want to reset the monitor, use the button to select CANCEL and then press the SELECT (or SET) button. This item allows you to reduce the degree of moire. (Moire is caused by interference Horizontal Scan Line with the periodical dot screen). It is normally OFF(H:0/V:0). The moire adjustments may affect the focus of the screen. Moire adjustments may shake slightly while the moire reduction function is on. This is to adjust the alignment of red and blue fields. Use to adjust the purity on the screen if the color appears uneven. A12 Troubleshooting Check the following before calling for service. No image appears . Is the power cord of the • Check and see if the power cord is connected properly tomonitor connected? the power outlet. . Is the power indicator light • Press the Power button. on? . Is the power on and the • Adjust the brightness and the contrast. power indicator blue? . Is the power indicator • If the monitor is in power saving mode, try moving theflickering? mouse or pressing any key on the keyboard to bring up the screen. . Do you see an "OUT OF • This message appears when the signal from the PCFREQUENCY" message (video card) is out of horizontal or vertical frequency rangeon the screen? of the monitor. See the 'Specifications' section of this manual and configure your monitor again. . Do you see a "SELF • This message appears when the signal cable betweenDIAGNOSITICS" message your PC and your monitor is not connected. Check theon the screen? signal cable and try again. The screen is flickering. . Is the vertical frequency less than 70Hz or is your monitor set to the interlaced mode? . Do you have any magnetic material such as adapter, or high- voltage line near to your monitor? . Do you hear a "~ding" sound while the monitor is flickering? • Set the vertical frequency to 72Hz or higher, and consult the video card user manual for instructions on converting to a non-interlaced mode. (You can set this option under the Display icon of the Control Panel.) • Remove magnetic sources, such as power adapters, speakers, or high-voltage lines, away from the monitor. • Use the normal degaussing function. This function clears the screen and reduces any screen blur that may occur due to the surrounding magnetic field. The screen may flicker for about 5 seconds, accompanied by a "~ding" sound. A13 Troubleshooting The screen color is not normal. . Do you see basic discoloration (16 colors)? . Is the screen color unstable or monochrome? . Do you see black dots on the screen? . Do you see a partial blurring on the screen? • Set the color depth to 256 colors or higher: use ' Control Panel '->' Display '->' Settings '->' Color Palette ' • Check the connection of the signal cable. Or pull out the video card of the PC and insert it again. • This is due to a small amount of foreign or abnormally florescent material that became fastened on the mask during manufacturing. It will not affect product performance. • This happens due to interference from surrounding magnetic fields, as created when speakers, steel structures, or high-voltage lines are placed near the monitor. Remove any such materials from the immediate vicinity and use the DEGAUSS icon on the screen adjustment menu to fix the screen. I see an after-image on the screen. . Do you...

Otros modelos de este manual:
Monitores - T730SHAK (323.81 kb)
Monitores - T730SHK (323.81 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría