button stuck. check all buttons and error will clear when the problem has been resolved This error message indicates that a button is stuck. Check all buttons. Error will clear when the problem has been solved. Contact service is problem persists. Using Default Function Values e-80 - eeprom error using default function values This error message indicates the control memory is not correctly reading user-set values. The Quickchiller will remain operational but the user defined settings will be reloaded to the default values. The control will revert to factory default settings and will require operator modification each time the unit is used. Call Service. Acknowledge error by pressing the power button. Probe Open/Shorted proben*open -or- proben*shorted call for service This error message indicates a problem with the probe identified within the display. The Quickchiller will operate normally in the Time mode but will not operate in the Probe mode. Call service. *N signifies probe number that is shorted: 1= top, 2= middle, 3= bottom Cavity Open Shorted cavity sensor open or shorted. call for service This error message indicates a problem with the interior cavity sensor. The Quickchiller will not operate in any operational mode. Call service. Coil Open Shorted coil n* open or coil n* shorted call for service This error message indicates a problem with the display identified coil sensor. The Quickchiller will remain operational but will extend the defrost cycle to the full period of 20 minutes. Call service. *N signifies coil number that is shorted. Bad Calibration e-81. bad calibration. please call service AD1-0=(PASS) (fail) AD1-1=(PASS)(FAIL) ad2-o=(pass)(fail) AD2-1=(PASS)(FAIL) AD3-0=(PASS)(FAIL) AD3-1=(PASS)(FAIL) Calibration bad. Call service. Note: Display will signify РЯББ where calibration is good, or FfíiL where calibration is bad. Requires Calibration e-82. requires calibration. please call service Requires Calibration. Call service. Power Failure power was off for hh.mm press program to acknowledge Power has been off. Press Program to acknowledge. NOTE: If such an event has occurred, it is strongly recommended that you ensure the food is safe for consumption according to local health regulations. QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 29 QC2-3 BOTTOM PARTS INFORMATION Item Part Description Qty. 1 RE-29821 Condensing Unit Duct 1 2 PE-29819 Top Louver Channel 1 3 PE-29830 Compressor Louver 1 4 SW-29823 Pressure Switch 1 5 LG-29904 6" Leg, Standard 4 CS-29822 3" Ranserve Caster Non Locking, Option 4 6 SC-29824 Bolt, 1/4-20 x 3.5" Shoulder Bolt Hex Head 16 7 BX-29820 Electrical Mounting Bracket 1 8 SC-29829 Bolt, 10-24x1/2 H/W/H 410 SS F08ZS Hex Head 12 9 FU-29901 Breaker, 2 Pole 20 Amp, QOU220 Universal 1 10 PN-29825 Condensate Evaporator Pan 1 11 EL-29828 Element, 115V 200W Evap. 000274 N 1 12 NU-29827 Nut, 10-24 Stainless Nylock 1 13 BT-29826 Tie Down Bracket for Elect Condensate Evaporator Heater 1 14 CD-29831 Cord with Plug, 20Amp 125V 5-20P, 9' Long 1 Quickchiller Parts • Quickchiller Owners Manual • 30 pARTS INFORMATION QC2-3 BOX VIEW Item Part Description Qty. 13 SC-29837 Screw, 1/4-20 x 5/8" Socket Set 18-8 SS 1 14 HG-29836 Hinge, Strap w/Collar 38mm L-Shaped 1 15 HG-29960 Unit Hinge Bracket 1 16 SC-29910 Screw, 10x2" THP TYPE A S M62G 410SS 4 17 CD-29831 Cord, 2 Prong Male, for Fan 1 18 BX-29843 Electrical Box 1 19 HL-29840 Food Probe Holder 1 20 PG-35098 Plug, 3/4" Grommet 5 21 SC-29835 Screw, 10x1/2" T/H/P 410 S/S M4XG 3 22 ST-35099 Stud, Side Rack Mounting (not shown) 4 Item Part Description Qty. 1 BT-29841 Holding Bracket Ref Line 1 2 PR-34299 Probe Receptacle Assembly 1 3 PR-34298 Probe, Quick Connect 1 4 SR-29832 Stainless Steel Side Rack 5 BU-29937 Bushing, Nylon Hinge 118 1 6 SC-29839 Screw, 10x1/2" Slot 1 7 GS-29838 Gasket, 15.59 x 24.25 Push In Press In 1 8 DR-29833 27x17 Door, Hinged Left 1 9 HG-29959 Hinge, Top Door, Left Hand Channel 1 11 SC-29835 Screw, 1/4-20 x 5/8" Socket Set 18-8 SS 1 12 HG-29834 Hinge, Spring Load Assembly, Self-Closing 1 Quickchiller Parts • Quickchiller Owners Manual • 31 parts information QC2-3 coil view Item Part Description Qty. 1 GD-29848 Fan Guard 1 2 GD-29850 Fan Shroud Assembly 1 3 FA-29854 Blade, 12" Evaporator Fan 1 4 FA-29853 Motor, Fan ESP-OL75EM14 1 5 SC-29855 Bolt, 10-24x5 Phillip Truss 19 6 BT-29847 Evaporator Coil Mounting Bracket 2 7 VA-29852 Valve, 1/4 Ton R404 L-T MOP 1 8 RE-29846 Coil Assembly, 12x17-1/4 Blast Chiller 3EX-0802C 1 Item Part Description Qty. 9 CD-29831 Cord, 2 Prong 24" Female 1 10 CD-29858 Cord, 2 Prong 24" Male 1 11 PN-29851 Drain Pan with Tubing, Evaporator BC-3 1 12 BT-29849 Fan Mounting Bracket 2 13 CD-29860 Wire, 11" Loop, Drain Heater 1 14 SN-34663 Sensor,1-3/4" RTD, Shrink Tubing 1 15 SN-33541 Sensor, 1-3/4" Long 1 16 NU-29827 Nut, 10-24 Stainless Nylock 4 Quickchiller Parts • Quickchiller Owners Manual • 32 parts information...

Otros modelos de este manual:
Congeladores - QC2-100 REMOTE (6.79 mb)
Congeladores - QC2-20 (6.79 mb)
Congeladores - QC2-3 (6.79 mb)
Congeladores - QC2-40 (6.79 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría