Fabricar: Brown and Son WA
Tamaño del archivo: 369.15 kb
Nombre del archivo: ed7898e3-c51e-454e-bcf1-c14a3f8385ee.pdf
|
Resumen del manual
A. Brown & Son, Inc. Models W.A. Brown & Son, Inc. 209 Long Meadow Drive • Salisbury, NC 28147 Phone: 704-636-5131 • Fax: 704-637-0919 Website: Table of Contents Page No. Cam Lock Installation ............................................................................3 Door Section Maintenance ............................................................17-19 Drop Off (factory assembled) Walk-Ins................................................11 Duro-Last Roof Cap Installation ............................................................8 EZ Pack Refrigeration Installation ......................................................12 Fiber Cement Panel Installation ............................................................9 Final Check List & Cleaning ................................................................12 Floor Preparation & Installation ............................................................2 Treadplate Overlay ................................................................................2 Floorless Walk-In Layout & Installation..................................................3 How to Call for Service ........................................................................15 Membrane Roof Cap for Outdoor Units ............................................7-8 Multiple Compartment Installation ......................................................6-7 Quick Set Roof Cap & Curb Installation ..............................................13 Replacing a Pressure Relief Port ........................................................22 Receiving and Uncrating........................................................................1 Replacing Door Gasket........................................................................20 Replacing Door Heater Cable..............................................................19 Replacing the Digital Thermometer ....................................................22 Replacement Parts Ordering ..............................................................15 Terminology............................................................................................1 Top Panel Installation ......................................................................6, 10 Trouble Shooting Guide ......................................................................26 Wall Panel Installation............................................................................5 Wainscotting Installation ........................................................................5 Warranty ..............................................................................................16 What to do when there is Freight Damage............................................1 Wind or Seismic Load Installation ........................................................4 Wiring Diagrams ............................................................................23-25 TAI200D Alarm ....................................................................................27 Receiving and Uncrating Congratulations! You have purchased a brand new W.A. Brown & Son, Inc. Walk-In Cooler or Freezer. To ensure proper set-up and many years of trouble free use, read and follow these instructions carefully before and during installation. This manual covers the basic installation of a standard walk-in. See sheets enclosed with shipment for installation instructions for items not covered in this manual. If You Have Freight Damage: Brown walk-ins are shipped on pallets with shrink wrap, in dedicated trucks or in specially marked and designated cartons. These methods have been chosen to decrease the possibility of freight damage, however, each shipment should be inspected for exterior damage. If damage is found, please note it on the delivery freight bill and call W. A. Brown Customer Service. Under NO conditions may a damaged unit be returned to W. A. Brown & Son, Inc. without first obtaining permission. Checklist Suggestions: • Read and understand the installation manual and cooler drawings before attempting to install the walk-in. • Make sure you have the number of pallets or crates listed on the Bill of Lading. • Remove all panels from their shipping cartons and stack them in rows of like panels; wall panels in one row, ceiling panels in another, etc. Panels with a 6" yellow sticker are non-standard panels and have a particular location in the walk-in. This number can be found on the drawing identifying the location of these panels. All standard panels are interchangeable. You do however, have to put the proper size in the proper location. • The refrigeration should be inspected upon receipt. • Check the shipping list to insure you have the correct number of panels, doors and accessories. If any problems are found, please contact the factory as soon as possible. • Locate accessories box for buttons, assembly wrench and a drawing. • Panels that have a PVC protective covering on the metal skins should have the PVC r...