Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Electrolux, modelo 1254-6 iU

Fabricar: Electrolux
Tamaño del archivo: 337.86 kb
Nombre del archivo: 6fd028c9-0e98-4028-864b-09dbb2512ddc.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The dimensions of the recessed installation area must correspond with those indicated in the figure. 600 550min. 600 Remove covering and adjust the + bracket locking nuts. Push the appliance into place. + The plug socket necessary for connection of the appliance to the electricity supply should be positioned, so that the plug is not placed in the recess. + Adjust height. + Mounting furniture door . Screw appliance into place. . Place the covering strip. 580 a = 100b = 150 25.80 A = 820B = 870 25 Fitting the plinth Important! For the efficient operation of the appliance, it is important that the original ventilation grid is used. • For an opening height dimension A=820 mm and a plinth height dimension a=100 mm, the plinth may be fitted without adjustments. The same applies to an opening height dimension B=870 mm and a plinth height dimension b=150 mm. • For plinth heights greater than a=100 mm, b=150 mm, a cut should be made in the plinth, 580 mm wide, in the centre of the appliance position, leaving a remaining height of a=100 mm, b=150 mm. • Attach plinth to the kitchen units. Important! The plinth must be positioned at a minimun distance of 25 mm from the door. Please check whether, after installing your appliance and especially after reversing the door, the door seal seals right round. A badly fitting door seal may lead to heavy frosting and result in a higher power consumption (see also “What to do if ...”). Power supply A correctly installed, earthed socket is required for the electrical supply. The supply must have a fuse rating of at least 10 Amps. If the socket is not accessible once the appliance is built in, the electrical installation must include suitable means of isolating the appliance from the mains (e.g. a fused spur). . Before initial start-up, refer to the appliance rating plate to ascertain if supply voltage and current values correspond with those of the mains at the installation location. e.g.: AC 220 ... 240 V 50 Hz or 220 ... 240 V ~50 Hz (i.e. 220 to 240 volts alternating current, 50 Hertz) The rating plate is inside the appliance on the left. The mains cable may only be changed by a qualified electrician or competent person. If your appliance needs repairing, please contact your local AEG Service Force Centre. Electrical Connection Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. WARNING – THIS APPLIANCE MUST BE EARTHED The manufacturer declines any liability should these safety measures not be observed. Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate. The rating plate is inside, on the left. The appliance is supplied with a 13 amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13 amp ASTA approved (BS 1362) fuse must be used. Important GREEN & YELLOW The wires in the mains lead are coloured in accordance with the following code: Green and Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: 1.The wire coloured green and yellow must be connected to the terminal marked with the letter “E” or by the earth symbol or coloured green and yellow. 2.The wire coloured blue must be connected to the terminal marked “N” or coloured black. 3.The wire coloured brown must be connected to the terminal marked “L” or coloured red. 4.Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath. Warning! A cut-off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut-off plug is disposed of safety. 13 AMP. FUSE BROWN CORD CLAMP BLUE 13 AMP Description of the appliance View of the appliance A A A A Freezer calender A Control panel A Drawer (only for storage) A Drawer (for storage and freezing) A Temperature display Prior to Initial Start–Up A A A A A A Please clean the appliance interior and all accessories prior to initial + start-up (see section: “Cleaning and Care”). Remove the ice pack from the appliance. + Only put the ice pack to freeze in the top drawer after the optimum + storage temperature of –18 °C has been reached. Re-freeze thawed ice packs in the same way, e. g. after cleaning the + appliance. Operating and indicator panel Important! Only use the appliance when built-in! 6 5 4 3 2 1 1 2 3 4 5 Thermostat control knob ON/OFF switch Pilot light (green) Warning light (red) Fast freeze light (yellow) 6 Fast freeze button and to switch off the warning tone The appliance can be activated/deactivated by pressing the ON/OFF switch (2). When the green pilot light (3) is illuminated this shows that the appliance is on. A coin in needed to turn the thermostat control knob (1). This makes it is more difficult to change the temperature setting accidentally (child protectio...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría