Resumen del manual


(TERMINATED UNUSED INPUTS) MIC EQ HI ±10 +/- 2dB AT 10KHz LOW ±10 +/- 2dB AT 100Hz CHANNEL EQ HI 9 +/- 2dB AT 13KHz -15 +/- 3dB AT 13KHz MID 9 +/- 2dB AT 1KHz LESS THAN -23dB AT 1KHz LOW 9 +/- 2dB AT 70Hz -26 +/- 3dB AT 70Hz POWER SOURCE AC 9V,1000mA DIMENSIONS 230 (W) X 267 (D) X 111 (H) mm WEIGHT 1.65Kgs CONNECTIONS 1) Connect the power cord to an AC outlet. 2) Connect the RCA cable to the PHONO input of your mixer. You can also use a line input by setting the phono/line switch at the rear of the turntable to Line. Note: This turntable has separate analog and digital circuits. If you are looking for a purely analog signal, use the Phono output. For access to the Key Lock feature use the Line output or S/P DIF output. T.80 TURNTABLE CONTENTS .. .. .. .. .. .... .. .... .... .... .... .... .... .... .. .... .... .... .. .. .... .... T.80 TURNTABLE CONTENTS 1) Start/Stop 2) Strobe Dots 3) Slipmat 4) Center Spindle 5) Motor ON/OFF Switch 6) Platter Revolution Speeds (RPM) 7) Target Light Base 8) Key Lock 9) Pitch Lock 10) Pitch Slider 11) Headshell Locking Nut 12) Tonearm 13) Pitch Select 14) Tone Arm Base 15) Counterweight 16) 45-rpm Adaptor Holder 17) Extra Stylus Holder 18) Reverse 19) Phono/Line Output 20) Phono/Line Switch 21) Digital Output 22) Power Cord Connector/Power Switch TONE ARM AND CARTRIDGE SETTINGS The major cause of problems in sound and skipping on the vinyl is the lack of proper set up of the needle and turntable adjustments. The needle is designed to operate at a specific angle to the vinyl. The T.80 has several adjustments to correctly position the needle to the vinyl. The first adjustment is the correct installation of the cartridge. Your cartridge is to be mounted into the headshell as pre the mounting instructions included with the cartridge. The Stanton 500,680 and 890 series of cartridges require the use of the two screws mounting into the headshell. For your convenience, some of these products can be purchased already mounted and pre-adjusted from your local Stanton dealer. If you are using these 1/2” mounted products with a headshell in a mobile application or you are doing heavy scratching, May want to use an extra shell weight. The Master series of products (Trackmaster, Groovemaster, etc.) are designed with their own mounting that eliminates the need for a separate headshell and the wiring to the cartridge. The body of the cartridge should be parallel with the centerline of the headshell-tone arm, when viewed from the front to the back. The second adjustment is at the installation of the cartridge-head-shell assembly into the tone arm tube lock. Holding the tone arm tube in one hand, insert the cartridge-headshell into the tube lock with the other hand. Turn the lock ring clockwise (when viewed from the rear) until the headshell is locked tightly into the tone arm. Remove the needle protector from the cartridge and place the needle on record. View the needle from the front and insure that the needle is perpendicular to the record surface. If some adjustment is needed, simply loosen the lock ring and rotate the cartridge-headshell until the needle is perpendicular to the record surface. Then re-tighten the lock ring. The third adjustment is the needle (or stylus) pressure. Start with the cartridge-headshell assembly mounted into the tone arm. Remove any needle protectors provided. With tone arm free, adjust the tone arm counterweight by rotating the rear section until the tone arm floats in a balanced condition above the record or mat. Do not allow the needle to drop onto the mat or the turntable platter during this adjustment. You might damage the needle tip. Now, carefully hold the tone arm in one hand while rotating the numbered ring on the front of the counter-weight with the other hand to the “0” setting. Next, without touching the numbered ring, Rotate the rear counterweight until the desired needle pressure reading is next to the line on top of the tone arm tube, see the instructions. Included with your cartridge for proper settings. ASSEMBLY Remove all the parts from the box. Please check to make (5) 500B Cartridge and Headshell sure the following items are included with the main unit in the (6) AC cord carton: (7) RCA cable (8) Target light (1) Platter (9) Operating instructions (2) Slip mat (10) Cloth dust cover (3) Counterweight (4) 45-rpm adapter SPECIFICATIONS POWER SOURCE AC 100V, 50/60Hz (For Japan) AC 110V, 60Hz (For Taiwan) AC 120V, 60Hz (For U.S.A.,Canada,Mexico) AC 220V, 50Hz (For United Arab Emirates,Chile,Argentina) AC 220V, 60Hz (For Philippines) AC 230V, 50Hz (For Europe,New Zealand,South Africa,Singapore,Israel) AC 240V, 50Hz (For Australia,U.K.) POWER CONSUMPTION 10 Watts DIMENSIONS 452 (W) x 370 (D) x 86 (H) mm WEIGHT 8.6 Kgs Stanton Magnetics, Inc. – Warranty Provision – Returns for Repairs or Replacement WARRANTY Through Stanton’s authorized dealers around the World, Stanton, or one of Stanton’s authorized distributors outside the U.S., will, without ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría