Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario DHD Power Cruiser, modelo 52

Fabricar: DHD Power Cruiser
Tamaño del archivo: 1.19 mb
Nombre del archivo: a439.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The Communication Controller RM420-852/853 in the DSP frame is the communication interface between the DSP frame and the connected modules on one side and the ethernet network for configuration and controlling on the other side. You can find three RJ45 connectors and one USB interface on this module. © 2009 DHD Deubner Hoffmann Digital GmbH Specifications and design are subject to change without notice. The content of this document is for information only. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does neither convey nor imply any license under patent rights or other industrial or intellectual property rights. Assembling and Wiring the Hardware Controller modules for the 52/RX. Since the revision RM420-852B/853B, the upper RJ45 connector provides an RS422 interface (not useable as RS232). On previous modules this port has no function. The middle connector of the three jacks is the interface to the controller network. Connect your console(s) to this RJ45 jack. Therefore, connect this port to a PoE switch, as well as all the fader and control modules and TFT displays. All modules of this network own an unique IP address, which should not be changed. In the system drawing above the required PoE switch is installed in a power frame. It is also possible to mount the PoE switch next to the console and to use a separate power supply. For configuration and controlling processes, as well as communication with other DHD Systems, the device can be connected to a PC or a local network via the lower RJ45 connector. The DHD system can get any IP address in this network. Use the USB port of the communication controller module if you want to connect directly to the device for maintenance. General Information Please use CAT5 cables continuous for wiring. But DHD recommends to use CAT6 cables for longer distances. The maximum length of the Ethernet cable between two modules of the Controller network is 100 meters (for instance between the Communication Controller of the DSP frame and a PoE switch or between a PoE switch and 52-4050 Controllers - that are included in the 52/XR fader and control modules. Use only switches in the DHD network and the controller network, which are shipped and/or recommended by DHD for the usage in these networks. Especially the switches must be Unmanaged Switches working with a speed of 100 Mbit/s. The following switches are tested by DHD and are recommended for the usage in DHD Ethernet networks: Manufacturer Type 3com Superstack 3, Baseline Switch 16 Port 10/100 Ref. 3C16470 3com Superstack 3, Baseline Switch 24 Port 10/100 Ref. 3C16471 Version 1.1.0 - 14.12.2009 Specifications and design are subject to change without notice. The content of this document is for information only. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does neither convey nor imply any license under patent rights or other industrial or intellectual property rights. Series 52 - 52/RX Mixing Console Installation Guide Manufacturer Type Allied Telesyn AT-FS713FC/SC 12x RJ45 1x SC Allied Telesyn AT-FS708 8x RJ45 5.1.1 Meaning of the Controller Module LEDs The meaning of the LEDs are identical for the RM420-852 and the RM420-853 Communication Controller modules. Meaning of the LEDs of the RM420-852 and the RM420-853 Communication Controller modules. 1. Reserved for future functions. 2. RM420-852/853: Reserved for future functions. | RM420-852B/853B: Booting process successful ("Done"), must always turn on several seconds after switching on or resetting the module. During operation, the LED is then permanently illuminated. On the RM420-852/853 the corresponding LED is located behind the front panel above the USB connector and is only visible through the little gap. 3. This LED is permanently on if a connection is established to the controller network. 4. The LED flashes during data is received from the controller network. 5. This LED is permanently on if a connection is established to the DHD network. 6. The LED flashes during data is received from the DHD network. © 2009 DHD Deubner Hoffmann Digital GmbH Specifications and design are subject to change without notice. The content of this document is for information only. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does neither convey nor imply any license under patent ri...

Otros modelos de este manual:
Instrumentos Musicales - RX (1.19 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría