Iniciar sesión:
Votos - 5, Puntuación media: 4 ( )

Manual de usuario Roland, modelo EF-303

Fabricar: Roland
Tamaño del archivo: 2.2 mb
Nombre del archivo:
Idioma del manual:ende
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


16 SYN RHYTHM REVERB TIME (Notenwert) REVERB LEVEL0~127SNARE LEVEL0~127 HH LEVEL0~127 DIR-MIX-EFX0~127 [SYN PREVIEW] function EFFEKT-PARAMETER-TABELLE MIDI-Implementation MIDI-Implementation EF-303 Date: Jul. 26 2000 Version: 1.00 Symbol Description Range n MIDI Channel 0H - FH (ch.1 - ch.16) vv Control value 00H - 7FH (0 - 127) kk Note Number 00H - 7FH (0 - 127) xx ON/OFF 00H - 3FH (0 - 63:OFF), 40H - 7FH (64 - 127:ON) 1. MIDI messages used by the sound source section Channel voice messages Note Off status 2nd byte 3rd byte 8nH kkH vvH 9nH kkH 00H * Not received by the effect algorithm. Note On status 2nd byte 3rd byte 9nH kkH vvH * Not received by the effect algorithm. Control Change .General purpose Controller1 - 4 (Controller number 2 - 5, 7 - 31, 64 - 95) status 2nd byte 3rd byte BnH 02H-5FH vvH Program Change status 2nd byte CnH ppH pp=Program number: 00H - 0FH (prog.1 - prog.16) * Not received when the Rx Program Change parameter is OFF. Pitch Bend Change status 2nd byte 3rd byte EnH llH mmH mm,ll=Pitch Bend value: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191) * Not received when the Rx SW parameter is OFF. * Not received by the effect algorithm. Channel Mode messages Reset All Controllers (Controller number 121) status 2nd byte 3rd byte BnH 79H 00H * Not received when the Rx SW parameter is OFF. * When this message is received, the following controllers will be set to their reset values. Controller Resetvalue Pitch Bend Change 0 (center) Modulation 0 (off) Portament off All Note Off (Controller number 123) status 2nd byte 3rd byte BnH 7BH 00H * When All Note Off is received, all currently sounding notes of the corresponding channel will be turned off. Omni Off (Controller number 124) status 2nd byte 3rd byte BnH 7CH 00H * The same processing as when All Note Off is received will be done. Omni On (Controller number 125) status 2nd byte 3rd byte BnH 7DH 00H * The same processing as when All Note Off is received will be done. The instrument will not be set to OMNI ON. Mono (Controller number 126) status 2nd byte 3rd byte BnH 7EH mmH mm=Mono number: 00H - 10H (0 - 16) * The same processing as when All Note Off is received will be done. Poly (Controller number 127) status 2nd byte 3rd byte BnH 7FH 00H * The same processing as when All Note Off is received will be done. System Realtime messages Timing Clock status F8H * This is received when Sync Mode is SLAVE. Settings can be made to synchronize the LFO rate. Active Sensing status FEH * When an Active Sensing message is received, the unit will begin monitoring the interval at which MIDI messages are received. During monitoring, if more than 420 ms passes without a message being received, the same processing will be done as when All Sound Off, All Note Off, and Reset All Controllers messages are received. Then monitoring will be halted. System Exclusive messages status data byte status F0H iiH, ddH, ......, eeH F7H F0H: System Exclusive message status ii = ID number: This is the ID number (manufacturer ID) that specifies the manufacturer whose exclusive message this is. Roland’s manufacturer ID is 41H.ID numbers 7EH and 7FH are defined in an expansion of the MIDI standard as Universal Non-realtime messages (7EH) and Universal Realtime Messages (7FH). dd,..., ee = data: 00H - 7FH (0 - 127) F7H: EOX (End Of Exclusive) This is the last status of system exclusive message. Data Request 1 RQ1 This message requests the other device to transmit data. The address and size indicate the type and amount of data that is requested. When a Data Request message is received, if the device is in a state in which it is able to transmit data, and if the address and size are appropriate, the requested data is transmitted as a Data Set 1 (DT1) message. If the conditions are not met, nothing is transmitted. The model ID of the exclusive messages used by this instrument is 00 33H. status data byte status F0H 41H, dev, 00H, 33H, 11H, aaH, bbH, F7H ccH, ddH, ssH, ttH, uuH, vvH, sum Byte Remarks F0H Exclusive status 41H ID number (Roland) dev device ID (dev: 10H - 1FH) 00H model ID (EF-303) 33H model ID (EF-303) 11H command ID (RQ1) aaH address MSB bbH address ccH address ddH address LSB ssH size MSB ttH size uuH size vvH size LSB sum checksum F7H EOX (End Of Exclusive) * This message is not received if the Rx.Sys-Ex parameter is OFF. MIDI-Implementation Data Set 1 DT1 This message transmits the actual data, and is used when you wish to set the data of the receiving device. status data byte status F0H 41H, dev, 00H, 33BH, 12H, aaH, bbH, F7H ccH, ddH, eeH, ... ffH, sum Byte Remarks F0H Exclusive status 41H ID number (Roland) dev device ID (dev: 10H - 1FH) 00H model ID (EF-303) 33H model ID (EF-303) 12H command ID (DT1) aaH address MSB bbH address ccH address ddH address LSB eeH data: The actual data to be transmitted. Multi-byte data is transmitted in the order of the address. : : ffH data sum checksum F7H EOX (End Of Exclusive) * Data whose size is greater than 128 bytes should be d...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría