Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Roland, modelo SX-700 MIDI

Fabricar: Roland
Tamaño del archivo: 6.75 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


1.1996 Model SX-700 Version: 1.00 1. RECOGNIZED RECEIVE DATA CHANNEL VOICE MESSAGE Note On Status Second Third 9nH WcH n - MIDI Channel kk ■ Note Number w « Velocity wH : OH - FH (ch.l - ch.16) :OOH - 7FH ( 0 - 127) : ООН - 7FH ( 0 - 127) • By specifying these messages as a source for "realtime parameter control" you can use Note On messages to control a target. Control Change Status_Second_Third_ BnH ccH MIDI Channel Control Number wH : OH - FH (ch.l - ch.16) :00H , 20H ( o, 32) : 01H - 1FH ( 1 * 31) : 40H - 5FH ( 64 - 95) : ООН - 7FH ( 0 - 127) w - Control Value * A controller number of 00H or 20H is recognized as a Bank Select message. The Bank Select setting makes the callup of the Program Number change when a Program Change message is received. When 00H: If the values are 00H and 03H or more, the unit switches to the Program Change number of the Program Change Map when a Program Change message is received. If the value is 01H, the unit switches to a User Area patch from 1 to 128 when a Program Change message is received. If the value is 02H, the unit switches to a Preset Area patch from 1 to 128 when a Program Change message is received. When 20H: Received data is ignored, regardless of the value. * Bank Select processing is held until a Program Change message is received. * By specifying these messages as a source for "realtime parameter control" you can use Control Change messages to control a target. Program Change Status_Second_ CnH ppH n - MIDI Channel pp * Program Number : OH - FH :00H - 7FH (ch.l - ch.16) (No.l - No.128) * Patches will be selected according to the program number that is received. * The Patch changes individually, according to the BANK SELECT value. Channel pressure Status_Second_ DnH wH Pitch Bend Change Status Second Third EnH 11H n - MIDI Channel 11 * Data LSB m « Data MSB mH : OH - FH (ch.l - ch.16) :00H - 7FH ( 0 - 127) :00H - 7FH ( 0 - 127) * By specifying these messages as a source for "realtime parameter control" you can use Pitch Bend messages to control a target. SYSTEM REAL TIME MESSAGE Status F8H * When you set "MIDI" on "TpSrc(TEMPO Source)" parameter, you can control the delay time. SYSTEM EXCLUSIVE MESSAGE Status_Data Byte_Status _ FOH iiH,ddH ...eeH F7H FOH » System Exclusive ii - Manufacturer ID :41H (Roland ) dd ,..ee - Data :00H - 7FH (0 - 127) F7H * EOX (End of Exclusive/System common) * For more details, please refer to "Roland Exclusive Message". 2. TRANSMITTED DATA SYSTEM EXCLUSIVE MESSAGE Status_Data Byte Status_ FOH iiH.ddH...eeH F7H FOH » System Exclusive ii “ Manufacturer ID :41H (Roland ) dd ,.. ee ■ Data :00H - 7FH (0-127) F7H » EOX (End of Exclusive/System common) ’ For more details, please refer to "Roland Exclusive Message". n - MIDI Channel w * Pressure Value : OH - FH (ch.l - ch.16) : ООН - 7FH ( 0 - 127) * By specifying these messages as a source for "realtime parameter control" you can use Channel Pressure messages to control a target. -1- SX-700 MIDI Implementation ваге 3. EXCLUSIVE COMMUNICATION On the SX-700, exclusive messages can be used as follows. - Transmit/receive SX-700 system/patch data. The model ID for SX-700 exclusive messages is 7AH. ONE WAY COMMUNICATION Request Dalai RQ1(11H) Byte Description FOH Exclusive Status 41H Manufacturer ID(Roland) Dev Device ID(Dev-00H-1FH) 7AH Model ID(SX-700) 11H Command ID(RQl) aaH Address MSB bbH Address ccH Address LSB ssH Size MSB ttH Size uuH Size LSB sum Checksum F7H E0X(End of System Exclusive) * SX-700 dose not transmit this message. Data Set1 DT1(12H) Byte_Description FOH 41H Dev 7АЯ 12H aaH bbH ccH eeH ffH sum F7H Exclusive Status Manufacturer ID(Roland) Device ID (Dev-00H-1FH) Model ID (SX-700) Command ID(DTI) Address MSB Address Address LSB Data Data Checksum E0X(End of System Exclusive) 4. ADDRESS MAPPING OF PARAMETERS (Model ID = 7AH) The address and size are displayed under 7-bit hexadecimal notation. Address MSB LSB Binary 7-bit Hexadecimal Size Oaaa aaaa AA MSB Obbb bbbb Occc cccc CC LSB Binary 7-bit Hexadecimal Osss ssss SS Ottt tttt Ouuu uuuu TT UU Parameter base address Address Block Map Address Block Sub Block 00 00 ООН +- 40 04 ООН 40 14 ООН I SÏSTEM I PARAMETERS 00 04 ООН 00 14 ООН I OF 74 ООН I 10 04 ООН ♦- 10 14 ООН I IF 7F 7FH +- End Of Bulk Mark 20 00 00H +- temporary Patch Parameters 40 00 00H +- I SÏSTEM I PARAMETERS PROGRAMS PARAMETERS The actual address of each parameter is the start address of the block plus the offset 1 1 | | I User Patch No.128 | address. +-+ . 50 04 00H +-t +-► You cannot use any address having "#" for the top address in a system exclusive I PROGRAMS | I Preset Patch No.l | message. I PARAMETERS | I Parameters | 1 1 50 14 00H | | i-h 1 1 I Preset Patch No.2 | 1 1 I 1 I Parameters | +-^ 5F 74 00H 1 PATCH 1 1 PARAMETERS | 1 1 1 User Patch 1 Parameters -1- -(• No.l 1 1 -1 1...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría